• Title/Summary/Keyword: Power supply noise

Search Result 484, Processing Time 0.027 seconds

Squeeze Film Dampers for High Temperature Superconducting Radial Magnetic Bearings (반경방향 고온초전도베어링의 Squeeze Film 댐퍼 설계)

  • Na, Uhn-Joo;Park, Sang-Kyu;Sung, Tae-Hyun;Han, Young-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.343.2-343
    • /
    • 2002
  • Squeeze film dampers(SFDs) are designed and analyzed for radial superconducting bearings. The designed SFDs are mounted on the superconductors submerged in liquid nitrogen such that the dampers should supply additional damping to the relatively underdamped superconducting bearing support. Basic theory of SFD with superconducting bearing are introduced. Rotordynamic simulations are provided to support the feasibility of the superconducting magnetic bearings mounted on SFDs for a horizontal flywheel energy storage system.

  • PDF

Vibration Suppression Using Eddy Current Damper (와전류 감쇠기를 이용한 진동 억제)

  • Kwak, Moon-Kyu;Lee, Myeong-Il;Heo, Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.10
    • /
    • pp.760-766
    • /
    • 2003
  • This paper is concerned with the eddy current damper which can be used to enhance the damping of the host structure. The operating principle of the eddy current damper is first explained in detail. The dynamic interaction between the magnets and the copper plate produces eddy current thus resulting in the damping force. By attaching the eddy current damper to the host structure, the damping of the total structure can be increased so that vibrations can be suppressed. The advantage of the eddy current damper is that it doesn't require any electronic devices and power supply The effect of the eddy current damper on the global dynamic characteristics of the structure is investigated by considering the cantilever with the eddy current damper. Experimental results show that the eddy current damper is an effective device for vibration suppression.

Development of the Measurement Tool and Impedance Test Method for the Signal fidelity in PCB Tracks (PCB 트랙의 신호충실성을 위한 임피던스 계산 방법 및 측정 툴 개발)

  • 라광열;유재현;김철기;이재경;남지현;윤달환
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.51-54
    • /
    • 2002
  • As digital systems continue to use components with faster edge rate and clock speeds, transmission of the digital information can take place many troubles. The increasing requirement for controlled impedance PCBs becomes both a critical success factor and a design challenge. Especially, the noise sources in digital system include the noise in power supply, ground and packaging due to simultaneous switching of signal, signal reflections and distortions on single and multiple transmission lines. This paper simulates the tracks controlled impedance with the test coupon. So, it can saves the design time and supports the economical PCB design.

  • PDF

A Transformer Feedback CMOS LNA for UWB Application

  • Jeon, Ji Yeon;Kim, Sang Gyun;Jung, Seung Hwan;Kim, In Bok;Eo, Yun Seong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.754-759
    • /
    • 2016
  • A transformer feedback low-noise amplifier (LNA) is implemented in a standard $0.18{\mu}m$ CMOS process, which exploits drain-to-gate transformer feedback technique for wideband input matching and operates across entire 3~5 GHz ultra-wideband (UWB). The proposed LNA achieves power gain above 9.5 dB, input return loss less than 15.0 dB, and noise figure below 4.8 dB, while consuming 8.1 mW from a 1.8-V supply. To the authors' knowledge, drain-to-gate transformer feedback for wideband input matching cascode LNA is the first adopted technique for UWB application.

Study about the Design of Special Blade and Simulation for Wind Generation system (풍력발전 시스템의 특수 블레이드 설계 및 시뮬레이션에 관한 연구)

  • Yoon, Jeong-Phil;Lee, Gi-Je;Yoon, Hyung-Sang;Yoon, Seok-Am;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.192-195
    • /
    • 2004
  • Into investment expense that wind generation system that is one of clean energy is less than existent energy in narrow shipfitter maximum effect to source of energy that have Eoteulsu evaluate. There is shortcoming that Blade structure of existent aerogenerator faces at problem of safety accident in overpopulated area and noise and have additional expense of supply of electric power equipment. In this paper, We wish to supplement problem that is such through design of special Blade structure that have noise reduction and stability. Wish to achieve design and simulation of blade to use CATIA for this, and analyze adaptedness of system.

  • PDF

Innovative cable force monitoring of stay cables using piezoelectric dynamic strain responses

  • Nguyen, Khac-Duy;Huynh, Thanh-Canh;Lee, Ji-Yong;Shin, Sung Woo;Kim, Jeong-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.830-834
    • /
    • 2013
  • This study presents a method to monitor cable force of a long-span cable-stayed bridge using a smart piezoelectric sensor system. The following approaches are implemented in order to achieve the objective. Firstly, the method to utilize piezoelectric materials for the health monitoring of stay cables is presented. For strain measurement of a stay cable, a PZT-embedded smart skin is designed to overcome the difficulties of bonding PZT sensors directly on stay cables. Secondly, a piezoelectric strain monitoring system for stay cables is designed. For the operation of the sensor board, the Imote2 sensor platform is used to provide the computation, wireless communication and power supply units. The feasibility of the proposed monitoring system is then evaluated on a full-scale cable of a cable-stayed bridge.

  • PDF

Abnormal vibration of steam turbine due to carbon deposit at journal bearing in 500MW thermal power plant (탄소 고형물에 의한 터빈의 이상 진동)

  • 구재량;황재현;김연환;이우광
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.234-238
    • /
    • 2002
  • Lubricating oil supply system is an essential instrument for safe turbine operation. A lubricating condition may cause the abnormal vibration of turbine. In this paper we have discussed the abnormal vibration of turbine due to lubricating oil. Dusts of the air usually attach to end of the oil deflector and contact particles of the bearing oil. Dusts which were contacted particles of the bearing oil were changed into carbon deposit because of high temperature. therefore, carbon deposits occur abnormal vibration of the turbine when they contact a rotor. So, we have solved this problems through the various maintenance.

  • PDF

Vibration Suppression Using Eddy Current Damper (와전류 감쇠기를 이용한 진동 억제)

  • Kwak, Moon-K;Lee, Myeong-Il;Heo, Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.136-141
    • /
    • 2003
  • This paper is concerned with the eddy current damper which can be used to enhance the damping of the host structure. The operating principle of the eddy current damper is first explained in detail. The dynamic interaction between the magnets and the copper plate produces eddy current thus resulting in the damping force. By attaching the eddy current damper to the host structure, the damping of the total structure can be increased so that vibrations can be suppressed. The advantage of the eddy current damper is that it doesn't require any electronic devices and power supply. The effect of the eddy current damper on the global dynamic characteristics of the structure is investigated by considering the cantilever with the eddy current damper. Experimental results show that the eddy current damper is an effective device for vibration suppression.

  • PDF

A Design of Instrumentation Amplifier using a Nested-Chopping Technique (Nested-chopping 기법을 이용한 Instrumentation Amplifier 설계)

  • Lee, Jun-Gyu;Burm, Jin-Wook;Lim, Shin-Il
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.483-484
    • /
    • 2007
  • In this paper, we describe a chip design technique for instrumentation amplifier using a nested-chopping technique. Conventional chopping technique uses a pair of chopper, but nested chopping technique uses two pairs of chopper to reduce residual offset and 1/f noise. The inner chopper pair removes the 1/f noise, while the outer chopper pair reduces the residual offset. Our instrumentation amplifier using a nested chopping technique has residual offset under 100 nV. We also implement very low frequency filter. Since this filter needs very large RC time constant, we use a technique named 'diode connected PMOS' to increase R with small die area. The total power consumption is 3.1 mW at the supply voltage of 3.3V with the 0.35um general CMOS technology. The die area of implemented chip was $530um{\times}300um$.

  • PDF

Design of a Rceiver MMIC for the CDMA Terminal (CDMA 단말기용 수신단 MMIC 설계)

  • 권태운;최재하
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.65-70
    • /
    • 2001
  • This paper presents a Receiver MMIC for the CDMA terminal. The complete circuit is composed of Low Noise Amplifier, Down Conversion Mixer, Intermediate Frequency Amplifier and Bias circuit. The Bias circuit implementation, which allows for compensation for threshold voltage and power supply voltage variation are provided. The proposed topology has high linearity and low noise characteristics. Results of the designed circuit are as follows: Overall conversion gain is 28.5 dB, input IP3 of LNA is 8 dBm, input IP3 of down conversion mixer is 0 dBm and total DC current consumption is 22.1 mA.

  • PDF