• Title/Summary/Keyword: Power split

Search Result 304, Processing Time 0.023 seconds

Torque Ripple Suppression Method for BLDCM Drive Based on Four-Switch Three-Phase Inverter

  • Pan, Lei;Sun, Hexu;Wang, Beibei;Su, Gang;Wang, Xiuli;Peng, Guili
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.974-986
    • /
    • 2015
  • A novel inverter fault-tolerant control scheme is proposed to drive brushless DC motor. A fault-tolerant inverter and its three fault-tolerant schemes (i.e., phase A fault-tolerant, phase B fault-tolerant, and phase C fault-tolerant) are analyzed. Eight voltage vectors are summarized and a voltage vector selection table is used in the control scheme to improve the midpoint current of the split capacitors. A stator flux observer is proposed. The observer can improve flux estimation, which does not require any speed adaptation mechanism and is immune to speed estimation error. Global stability of the flux observer is guaranteed by the Lyapunov stability analysis. A novel stator resistance estimator is incorporated into the sensorless drive to compensate for the effects of stator resistance variation. DC offset effects are mitigated by introducing an integral component in the observer gains. Finally, a control system based on the control scheme is established. Simulation and experiment results show that the method is correct and feasible.

Oil-Jet Ball 윤활시 가스터빈용 고속 Ball Bearing 윤활특성

  • 김기태;권우성
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.04b
    • /
    • pp.86-93
    • /
    • 1996
  • The lubrication characteristics of high-speed ball bearings has been investigated empirically using 45mm bore split inner ring ball bearings employed in small industrial gas turbine engines with oil-jet lubrication method. For the close structural simulation, experiments carried out with bearing mounting supports of real engines, such as bearing housings and oil nozzle assemblies with squeeze film dampers. Thus the results of tests can be directly applied to the design and the development of gas turbine engines. Testing was done by varying operating speeds, axial load on bearings, and lubricant flowrates. During testing, the temperature of bearing at outer-ring face, the power consumption of the driving motor, and the rotating resistance of the bearing were measured. From this study, the representative factors for lubrication characteristics at high speed was found, and the most important one was not operating speed but axial load up to 1.95 million dmN speed and 303 kgf axial load. Furthermore, the detailed variation of the rotational resistance of the bearing could be visualized by measuring the change of the radial load under the bearing supports. The rotational resistance consists of the frictional resistance and the bearing-cavity oil resistance.

  • PDF

Analysis of dual-mode hybrid by using mode change parameter (모드 전환 상수를 이용한 듀얼 모드 하이브리드 해석 방법)

  • Kim, Nam-Wook;Yang, Ho-Rim;Ahn, Kuk-Hyun;Cho, Sung-Tae;Park, Yoeng-Il;Lee, Jang-Moo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.539-542
    • /
    • 2006
  • Many researches about next generation vehicles are trending toward HEV which has better fuel economy than an internal-combustion engine. But existing HEV has some defects at specific running states(eg. highway running It is possible that dual-mode hybrid system overcomes that defects. Mode change parameter, ${\gamma}$ helps to analyse the mode changing of dual mode hybrid and is applied at a numerical analysis on testing the performance. There is an additional constraint when vehicles drive on engine mode. No power assistance of battery applies on engine mode. Because vehicles must be sustained by only engine power while vehicle drives on constant speed mode. At the conclusion of this paper, graphs show the ability of motors that satisfy the equilibrium of the lever system. Designers can roughly determine capacities of the motors, parameters of the lever system by this analysing method.

  • PDF

Multi-homing in Heterogeneous Wireless Access Networks: A Stackelberg Game for Pricing

  • Lee, Joohyung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.5
    • /
    • pp.1973-1991
    • /
    • 2018
  • Multimedia applications over wireless networks have been evolving to augmented reality or virtual reality services. However, a rich data size compared to conventional multimedia services causes bandwidth bottlenecks over wireless networks, which is one of the main reasons why those applications are not used widely. To overcome this limitation, bandwidth aggregation techniques, which exploit a multi-path transmission, have been considered to maximize link utilization. Currently, most of the conventional researches have been focusing on the user end problems to improve the quality of service (QoS) through optimal load distribution. In this paper, we address the joint pricing and load distribution problem for multi-homing in heterogeneous wireless access networks (ANs), considering the interests of both the users and the service providers. Specifically, we consider profit from resource allocation and cost of power consumption expenditure for operation as an utility of each service provider. Here, users decide how much to request the resource and how to split the resource over heterogeneous wireless ANs to minimize their cost while supporting the required QoS. Then, service providers compete with each other by setting the price to maximize their utilities over user reactions. We study the behaviors of users and service providers by analyzing their hierarchical decision-making process as a multileader-, multifollower Stackelberg game. We show that both the user and service provider strategies are closed form solutions. Finally, we discuss how the proposed scheme is well converged to equilibrium points.

Two Modified Z-Source Inverter Topologies - Solutions to Start-Up Dc-Link Voltage Overshoot and Source Current Ripple

  • Bharatkumar, Dave Heema;Singh, Dheerendra;Bansal, Hari Om
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1351-1365
    • /
    • 2019
  • This paper proposes two modified Z-source inverter topologies, namely an embedded L-Z-source inverter (EL-ZSI) and a coupled inductor L-Z source inverter (CL-ZSI). The proposed topologies offer a high voltage gain with a reduced passive component count and reduction in source current ripple when compared to conventional ZSI topologies. Additionally, they prevent overshoot in the dc-link voltage by suppressing heavy inrush currents. This feature reduces the transition time to reach the peak value of the dc-link voltage, and reduces the risk of component failure and overrating due to the inrush current. EL-ZSI and CL-ZSI possess all of the inherent advantages of the conventional L-ZSI topology while eliminating its drawbacks. To verify the effectiveness of the proposed topologies, MATLAB/Simulink models and scaled down laboratory prototypes were constructed. Experiments were performed at a low shoot through duty ratio of 0.1 and a modulation index as high as 0.9 to obtain a peak dc-link voltage of 53 V. This paper demonstrates the superiority of the proposed topologies over conventional ZSI topologies through a detailed comparative analysis. Moreover, experimental results verify that the proposed topologies would be advantageous for renewable energy source applications since they provide voltage gain enhancement, inrush current, dc-link voltage overshoot suppression and a reduction of the peak to peak source current ripple.

Energy Management Technology Development for an Independent Fuel Cell-Battery Hybrid System Using for a Household (가정용 독립 연료전지-배터리 하이브리드 에너지 관리 기술 개발)

  • YANG, SEUGRAN;KIM, JUNGSUK;CHOI, MIHWA;KIM, YOUNG-BAE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.2
    • /
    • pp.155-162
    • /
    • 2019
  • The energy management technology for an independent fuel cell-battery hybrid system is developed for a household usage. To develop an efficient energy management technology, a simulation model is first developed. After the model is verified with experimental results, three energy management schemes are developed. Three control techniques are a fuzzy logic control (FLC), a state machine control (SMC), and a hybrid method of FLC and SMC. As the fuel cell-battery hybrid system is used for a house, battery state of charge (SOC) regulation is the most important factor for an energy management because SOC should be kept constant every day for continuous usage. Three management schemes are compared to see SOC, power split, and fuel cell power variations effects. Experimental results are also presented and the most favorable strategy is the state machine combined fuzzy control method.

Browning's Dramatic Monologue and Mulvey's Feminist Film Theory (멀비의 페미니즘 영화 이론으로 읽는 브라우닝의 극적 독백)

  • Sun, Hee-Jung
    • English & American cultural studies
    • /
    • v.17 no.2
    • /
    • pp.1-27
    • /
    • 2017
  • My aim in this paper is to provide a clear view of Victorian gender ideology and highlight the role played by Browning's dramatic monologues in the challenge against the strict patriarchal codes of the era. Laura Mulvey's Male Gaze theory in cinema is especially useful for understanding Browning's most well-known dramatic monologues, "Porphyria's Lover," and "My Last Duchess," because these poems are structured by polarities of looking and being looked at, the active and the passive. In her 1975 essay "Visual Pleasure and Narrative Cinema", Mulvey introduced the second-wave feminist concept of "male gaze" as a feature of gender power asymmetry in film. To gaze implies more than to look at – it signifies a psychological relationship of power, in which the gazer is superior to the object of the gaze. She declares that in patriarchal society pleasure in looking has been split between active/male and passive/female. Browning's women are subject to the male gaze, but they refuse to become the objects of a scopophilic pleasure-in-looking. Porphyria and the Duchess don't exist in order to satisfy the desires and pleasures of men. They reveal themselves as an autonomous being - reserved in Victorian gender dynamics for men. Mulvey advocates 'an alternative cinema' which can challenges the male-dominated Hollywood ideology. It is possible to say that Browning's dramatic monologues correspond to Mulvey's 'alternative cinema' because they show a counterview in terms of the representation of woman against the Victorian patriarchal ideology.

Practical Experimental Design Strategy and Analysis for the Comparison of Two Treatments (두 개의 처리 비교를 위한 실용적인 실험 계획 전략과 분석)

  • Lim, Yong-Bin
    • Journal of Korean Society for Quality Management
    • /
    • v.33 no.3
    • /
    • pp.156-160
    • /
    • 2005
  • We consider practical experimental design strategies and analysis to find out whether a modified method give better results than the standard method. The most practical design strategy is for experimenter to make r successive runs under the current standard method and then, change the standard method to a modified method to make another r successive runs under a modified method. To test a statistically significant difference between the population mean of the standard method and a modified method, additional recent data for sufficient number of consecutive responses under the standard method is needed to construct external reference distribution(Box, et al., 1968). Upon those informations unavailable, the practical design strategy is to run the experiment by split plot designs. In this paper, two types of split plot designs are proposed and how to determine efficiently the number of repetition within a given method and replication of those two methods are discussed based on results of the level of significance ${\alpha}$= 0.05 and the power being at least 0.9 at the detectable difference of ${\mu}_2-{\mu}_1=1.5{\times}{\sigma}$.

Nitrogen Split Application of Direct-seeded Rice in Tillage and No-tillage Systems (경운과 무경운 조건에서 벼 건답휴립직파재배의 질소분시비율)

  • 이석순;홍승범;백준호
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.5
    • /
    • pp.405-412
    • /
    • 1992
  • Growth characters of dry seeded paddy rice was studied at different levels of nitrogen(N) split application (basal : immediately after irrigation : 2 weeks after irrigation: 25 days before heading: heading stage with 10 : 20 : 30 : 20 : 20%, 20 : 30 : 20 : 20 : 10%, 30 : 40 : 0 : 20 : 10%, and 100% basal of slow release urea) in tillage and no-tillage systems. On May 17 in 1990, 6kg /10a of dry seeds of a breeding line of Milyang 95 was broadcasted and covered with a power tiller. Between tillage and no-tillage systems yield and its components, lodging related characteristics, and contents of cellulose, hemicellulose and lignin of culm base were similar. Leaf area index at heading stage was higher in tillage, but lodging index was lower compared with those in no-tillage plot. Culm length, effective tiller ratio, culm base weight, 1000-grain weight, harvest index in slow release N applied plot were higher compared with those in other N treatments. Grain yield of rice among levels of N split applications was similar in tillage, but it was higher in slow release N applied plot in no-tillage if 1kg /10a of additional N was applied as urea at panicle formation stage. At early growth stage N concentration and N uptake were lower in the slow release N applied plot, but higher after heading stage compared with other N treatments. The number of tillers was lowest in slow release N applied plot during the tillering stage, but the number of panicles per hill was similar to other N treatments.

  • PDF

3-Dimensional SVM Technique for the Three-Phase Four-Leg Voltage Source Inverter System (3상 4레그 전압형 인버터를 위한 3차원 공간벡터변조 기법)

  • Doan, Van-Tuan;Choi, Woo-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.111-112
    • /
    • 2013
  • The three-phase four-leg voltage source inverter (VSI) topology can be an interesting option for the three phase-four wire system. With an additional leg, this topology can handle the neutral current, hence the DC link capacitance can be reduced significantly. In this paper the three dimensional space vector modulation (3D SVM) in ${\alpha}{\beta}{\gamma}$ coordinates for the three-phase four-leg VSI is presented. By using the 3D SVM method, the DC link voltage can be reduced by 16% compared with the split DC link capacitor topology and the output distortion can also be reduced under the unbalanced load condition.

  • PDF