• Title/Summary/Keyword: Power line modem

검색결과 127건 처리시간 0.03초

전력선 모뎀을 이용한 조명기기 제어연구 (A Study On Controlling An illuminator Using Power-Line Modem)

  • 최현철;김희식;김웅찬;이재황
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.129-129
    • /
    • 2000
  • This paper describes the concept and method of Controlling an illuminator using Power-Line Modem. Nowadays it is being studied and developed the Power-Line communication. The communication using Power-Line can realize Building-Automation and Home-Automation easily and chiefly. Because it has no need constructing an additional equipment. In this study it is used The Power-Line Modem, illuminators and microcontrollers which enable RS-232C serial communication.

  • PDF

전력선/무선 통합 모뎀을 이용한 Door Lock의 원격 제어 시스템 (Remote Control System for the Door Lock by the Unified Modem with the Wireless and Power Line Modem)

  • 박종연;이후찬;최원호
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.189-193
    • /
    • 2005
  • In this paper we proposed the remote control system for the door lock by the unified modem with the wireless and the power line modem. We developed the management system program between the door-lock system and the proposed unified modem. The infrared communication system was used between the Door-Lock system and the power line modem. With the unified developed modem and the Door-Lock system, it is possible to control remotely the developed system in the internet service area.

  • PDF

듀얼 모드형 고신뢰 PLC 모뎀 칩 설계 및 구현 (Design and Implementation of the Dual-Mode Type Reliable PLC Modem Chip)

  • 이원태;최성수;윤성하;이영철
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.488-493
    • /
    • 2008
  • This paper represents a dual-mode type transmission technique for a high reliable narrow-band power line communication(PLC) modem, and its design and implementation of a system-on-chip(SoC). The proposed transmission technique is based on a Chirp modulation for the purpose of overcoming time variations of power line channel environments in the narrow-bandwidth of the frequency range of 95-145.5 kHz. The designed modem is fabricated utilizing a mixed 0.18 ${\mu}m$ CMOS technology. Especially, according to the power line channel environments the data transmission rate can be selectively changed into 2.5 kbps and 480 bps. The total hardware complexity of the implemented chip is about 50,000 gates, the power consumption is about 26mW, and the operating frequency is up to 5.12 MHz.

전력선통신모뎀의 전자계강도 측정방법 연구 (A Study for the Measurement Method of Electromagnetic Field Strength of Power Line Communications Modem)

  • 장동원
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2006년도 하계학술대회
    • /
    • pp.162-165
    • /
    • 2006
  • This paper describes a measurement method for electromagnetic field strength of power-line communications(PLC) modem. First it outlines the technology used in PLC modems, and the technical regulation being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this protection. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC modem mean that there is no consensus as yet as to how PLC modem components can be made compliant with EMC requirements globally. It is concluded that there is a measurement method according to CISPR standards which satisfy requirements in domestic regulation.

  • PDF

전력선 Modem과 Telephone을 이용한 가정 자동화 시스템의 실현 (Home Automation Implementation using Power Line Modem and Telephone)

  • 최승지;김한수;박종연
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.43-46
    • /
    • 2001
  • This paper has been studied a implementation Home Automation by PLM and Telephone system. The PLM is composed of FSK IC-chip and the circuit for the power line communication. In this paper load control was made with PIC16F84A and its communication speed was 1200 baud rates.

  • PDF

신뢰적인 전력선 통신을 위한 라인 커플러의 개발 (Development of the line coupler for reliable power line communication system)

  • 최원호;임병노;박종연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2009-2010
    • /
    • 2006
  • This paper presents an adaptive line coupler to match input impedance of the Power line Communication(PLC) modem between access impedance of the power line. This line coupler provides maximum signal power transmiting capability, high reliability. The structure of this coupler is simple and designed to make a easy and low cost. The proposed line coupler is suitable for Amplitude Shift Keying(ASK) or Phase Shift Keying(PSK) modem. To figure out our models, the analysis of the transmitting features of power line channel is performed in the time domain at the carrier frequency. As a result of this study, we present the values of capacitors in the capacitor bank and adaptive line coupler circuit.

  • PDF

FH방식의 전력선 모뎀에 의한 집단 조광제어 시스템 구현 (Implementation of dimming system using FH/SS Power Line Communication modem)

  • 최원호;박준용;노경호;박종연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.163-166
    • /
    • 2004
  • The conventional fluorescent lamp dimming system using an another control line is complex and will increased the cost. Therefore, many studies have focused on the wireless communication, but it is not fit for dimming system because of the interference generated by the infra-red light of lamp or switching noises in ballast. So, we applied the power line communication on the dimming system and we proposed a new coupling circuit using the voltage controlled impedance convertor for improving the performance of the FH/SS PLC modem. The performance for the proposed modem is evaluted by the BER.

  • PDF

저속 PLC 모뎀에서의 Chirp 신호 방식과 시스템 구현에 관한 연구 (A study for chirp signal method & system implementation in the PLC modem with low speed)

  • 정영화;이상건
    • 정보학연구
    • /
    • 제7권3호
    • /
    • pp.37-45
    • /
    • 2004
  • 제어 목적으로 주로 사용되는 기존의 60bps 급 저속 전력선 통신 모뎀에 적용된 대표적인 통신 방식은 단일 캐리어 방식이다. 단일 캐리어 방식은 전력선 통신 채널 환경에 매우 민감하다. 특히 채널의 notch 필터 특성에 따른 송신 신호의 극심한 감쇄는 통신 에러의 주 원인이 된다. 국내 전력선 채널 환경은 이러한 특징이 매우 강하다. 본 논문에서는 notch 특성 및 잡음 특성에 강한 Chirp 신호 방식을 이용한 저속 전력선 통신 시스템을 구현하였다. 본 연구에서는 1 비트에 대해 1ms 내에 100${\mu}s$의 1 Unit 심볼 Chirp 신호 10개를 전소하는 방식을 제안하였다. 또한 오류 정정을 위한 Convolution 부호와 충돌 감지 및 에러 검출을 위한 맨체스터 부호를 적용하였으며, 수신부에서 신호 검출을 위해 비트 상관기를 이용한 방식을 사용하였다. 60bps급 저속 전력선 통신 시스템을 구현하여 실험한 결과 Chirp 방식의 통신 방식이 단일 캐리어 방식에 비해 뛰어난 성능을 가짐을 확인하였다.

  • PDF

저속 PLC 모뎀을 위한 대기전력 절감 모듈 개발 (A Development of Module Operating on Standby-power Reduction for Low-speedy PLC Modem)

  • 김기현;김지홍;김남균;김상철;서길수;김은동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1537-1539
    • /
    • 2004
  • This paper introduces a supplementary module reducing the standby-power of Power Line Communication(PLC) modem, one of the network equipments that take up much of the stand-by power. This supplementary module consists of three parts, such as a compare part, a control part, and a switch part. This supplementary module controls the power going from the power supply element into PLC modem, which brings about the effect of standby-power reduction. It is assured that over $30\%$ standby-power reduction is estimated when we applied this module to a low-speedy PLC control modem.

  • PDF

제어용 PLC 모뎀을 위한 대기전력 절감 모듈 개발 (A Development of Module Operating on Standby-power Reduction for PLC Control Modem)

  • 김기현;김지홍;김남균;김상철;서길수;김은동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.296-299
    • /
    • 2004
  • This paper introduces a supplementary module reducing tile standby-power of Power Line Communication(PLC) modem, one of the network equipments that take up much of tile stand-by power. This supplementary module consists of three parts, such as a compare part, a control part, and a switch part. This supplementary module controls the power going from the power supply element into PLC modem, which brings about the effect of standby-power reduction. It is assured that over 30% standby-power reduction is estimated when we applied this module to a low-speedy PLC control modem.

  • PDF