• 제목/요약/키워드: Power farm

검색결과 530건 처리시간 0.025초

Improvement in Active Power Control Methods for a Wind Farm Based on Modified Wind Turbine Control in Danish Grid Codes

  • Sim, JunBo;Song, Il-Keun;Lee, Yongseung;Lee, Hak-Ju;Choi, Yun-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1438-1449
    • /
    • 2018
  • The importance of power system stability has been emphasized with an increase of wind energy penetration in the power system. Accordingly, the guarantee on various control capabilities, including active and reactive power control of wind farms, was regarded as the most important aspect for the connection to the grid. To control the wind farm active power, the wind farm controller was introduced. The wind farm controller decides the power set points for each wind turbine generating unit and each wind turbine generating unit controls its power according to the set points from the wind farm controller. Therefore, co-relationship between wind farm controller and wind turbine controllers are significantly important. This paper proposes some control methods of wind farm active power control based on modified wind turbine control for power system stability and structures to connect wind turbine controllers to wind farm controller. Besides, this paper contributes to development of control algorithm considering not only electrical components but also mechanical components. The proposed contributions were verified by full simulation including power electronics and turbulent wind speed. The scenario refers to the active power control regulations of the Eltra and Elkraft system in Denmark.

야산개발농지의 기계화 작업효율 증진에 관한 연구 (A Study on the Efficient Utilization of Farm Tractor and Power Tiller on the Inclined Upland)

  • 최규홍
    • 한국농공학회지
    • /
    • 제15권1호
    • /
    • pp.2925-2933
    • /
    • 1973
  • For the efficient utilization of farm machines on the inclined uqland, work performance in plowing, harrowing and terracing and critical workable gradients were tested on three farm machines which are 47 ps-farm tractor, 8 ps-power tiller and 5 ps-power tiller. The results of this study are summarized as follows; 1) The steeper the slope of the upland was the more inefficient the work performance of all machines was. 2) The critical workable gradients of the machines were proved as 14 for 47 ps-farm tractor, 12 for 8 ps-power tiller and 10 for 5ps-power tiller. 3) Plowing in the way of turning the furrow slices against the slope in order to build up terraces, the critical workable gradients were 8 for 47 ps-farm tractor and 8 ps-power tiller and 6 for 5 ps-power tiller. 4) Two-way plow is recommended for plowing with farm tractor on inclined upland, and high lug of tire would be good to prevent the slippage, and side valance-weight should be attached to power tiller for preventing its overturning.

  • PDF

대규모 풍력 발전 단지의 최적운영 방안 연구 (A Study on the Optimal Operation Schemes for Large-scale Wind Farm)

  • 전영수;최영도
    • 전력전자학회논문지
    • /
    • 제14권5호
    • /
    • pp.365-371
    • /
    • 2009
  • 국내에서는 풍력 발전 기술 집약에 전력하고 있지만 풍력 발전 단지에 대한 운영 경험은 매우 제한적이며, 연계 기준 수립에 대한 기초가 부족한 실정이다. 따라서 국내 계통의 특성을 고려한 연계 기준 및 최적 운영 방안 수립을 위하여 여러 국가에서 적용하고 있는 풍력 발전 단지의 연계기준 및 최적 운영 방안에 대한 검토가 필요하다. 이에 본 논문은 제주계통을 대상으로 한 모의를 통하여 대규모 풍력 발전 단지의 최적 운영 방안에 대한 필요성을 확인하고 제안한다.

A Reliability Model of Wind Farm Considering the Complex Terrain and Cable Failure Based on Clustering Algorithm

  • Liu, Wenxia;Chen, Qi;Zhang, Yuying;Qiu, Guobing;Lin, Chenghui
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1891-1899
    • /
    • 2014
  • A reliability model of wind farm located in mountainous land with complex terrain, which considers the cable and wind turbine (WT) failures, is proposed in this paper. Simple wake effect has been developed to be applied to the wind farm in mountainous land. The component failures in the wind farm like the cable and WT failures which contribute to the wind farm power output (WFPO) and reliability is investigated. Combing the wind speed distribution and the characteristic of wind turbine power output (WTPO), Monte Carlo simulation (MCS) is used to obtain the WFPO. Based on clustering algorithm the multi-state model of a wind farm is proposed. The accuracy of the model is analyzed and then applied to IEEE-RTS 79 for adequacy assessment.

풍력단지 출력 검증을 위한 기상탑의 최적위치 선정 (Optimal Location of Meteorological Mast for Power Curve Verification of Wind Farm)

  • 오기용;이준신;박준영;이재경;김지영
    • 신재생에너지
    • /
    • 제5권2호
    • /
    • pp.31-38
    • /
    • 2009
  • The performance test of a wind turbine in a wind farm is generally carried out by the owner to verify the power curve of the wind turbine given by the turbine manufacturer. The international electro-technical commission provides the IEC 61400-12-1 standard on "Power performance measurements of electricity producing wind turbines". By using this code, one can easily find the suitable met-mast (meteorological mast) location for the wind data whether a wind farm is potential or already built. In this paper, the valid sectors for wind turbines installed in the HanKyoung wind farm, south-west in Jeju island are analyzed on the basis of the code by considering the wind farm layout. Among these sectors, the optimal met-mast location is presented for the power curve verification of the wind farm.

  • PDF

풍력발전단지 탈락 시를 고려한 단지 출력 변동 저감을 위한 HESS의 용량 산정 (Determination of the HESS Capacity for Mitigation of Fluctuation of Wind Farm Output under Consideration of Disconnecting Wind Farm)

  • 김승현;고지한;김일환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.388-389
    • /
    • 2013
  • This paper presents the method for the fluctuation smoothing control by using relaxation time variable control of battery. When the output power of wind farm is changed suddenly, it is necessary to control the output power of wind farm. The smoothing relaxation time is changed within limits of battery output power. Using the hybrid energy storage system (HESS) combined with battery energy storage system and electric double layer capacitor, it is possible to control the output power of wind farm. The capacity of battery is determined by considering the case of the disconnecting wind farm from the grid. To verify the proposed method, simulations are carried out by using PSCAD/EMTDC with actual data of wind farm in the Jeju Island.

  • PDF

Economic analysis of a 22.9 kV HTS power cable and conventional AC power cable for an offshore wind farm connections

  • Jung, Ga-Eun;Dinh, Minh-Chau;Sung, Hae-Jin;Park, Minwon;Yu, In-Keun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.60-64
    • /
    • 2018
  • As the offshore wind farms increase, interest in the efficient power system configuration of submarine cables is increasing. Currently, transmission system of the offshore wind farm uses almost AC system. High temperature superconducting (HTS) power cable of the high capacity has long been considered as an enabling technology for power transmission. The HTS cable is a feasible way to increase the transmission capacity of electric power and to provide a substantial reduction in transmission losses and a resultant effect of low CO2 emission. The HTS cable reduces its size and laying sectional area in comparison with a conventional XLPE or OF cable. This is an advantage to reduce its construction cost. In this paper, we discuss the economic feasibility of the 22.9 kV HTS power cable and the conventional AC power cables for an offshore wind farm connections. The 22.9 kV HTS power cable cost for the offshore wind farm connections was calculated based on the capital expenditure and operating expense. The economic feasibility of the HTS power cable and the AC power cables were compared for the offshore wind farm connections. In the case of the offshore wind farm with a capacity of 100 MW and a distance of 3 km to the coast, cost of the 22.9 kV HTS power cable for the offshore wind farm connections was higher than 22.9 kV AC power cable and lower than 70 kV AC power transmission cable.

풍력발전단지의 계통연계 운전이 배전선 보호계전에 미치는 영향 (Influence of the Interconnected Wind farm on Protection for Distribution Networks)

  • 장성일;김광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.151-157
    • /
    • 2003
  • Wind farm interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with wind fm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may be difficult to detect the fault happened in the distribution network connected with wind generator This paper describes the effect of the interconnected wind turbine generators on protective relaying of distribution power lines and detection of the fault occurred in a power line network. Simulation results shows that the current level of fault happened in the power line with wind farm depends on the fault impedance, the fault location. the output of wind farm. and the load condition of distribution network.

Operation Scheme for a Wind Farm to Mitigate Output Power Variation

  • Lee, Sung-Eun;Won, Dong-Jun;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.869-875
    • /
    • 2012
  • Because of the nature of wind, the output power of wind turbines fluctuates according to wind speed variation. Therefore, many countries have set up wind-turbine interconnection standards usually named as Grid-Code to regulate the output power of wind farms to improve power system reliability and power quality. This paper proposes three operation modes of wind farms such as maximum power point tracking (MPPT) mode, single wind turbine control mode and wind farm control mode to control the output power of wind turbines as well as overall wind farms. This paper also proposes an operation scheme of wind farm to alleviate power fluctuation of wind farm by choosing the appropriate control mode and coordinating multiple wind turbines in consideration of grid conditions. The performance of the proposed scheme is verified via simulation studies in PSCAD/EMTDC with doubly-fed induction generator (DFIG) based wind turbine models.

그리드/연계선 사고 시 풍력발전단지의 응동 분석 (Analysis of Response of a Wind Farm During Grid/inter-tie Fault Conditions)

  • 이혜원;김연희;정태영;이상철;강용철
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1128-1133
    • /
    • 2011
  • In a wind farm, a large number of small wind turbine generators (WTGs) operate whilst a small number of a large generator do in a conventional power plant. To maintain high quality and reliability of electrical energy, a wind farm should have equal performance to a thermal power plant in the transient state as well as in the steady state. The wind farm shows similar performance to the conventional power plant in the steady state due to the advanced control technologies. However, it shows quite different characteristics during fault conditions in a grid, which gives significant effects on the operation of a wind farm and the power system stability. This paper presents an analysis of response of a wind farm during grid fault conditions. During fault conditions, each WTG might produce different frequency components in the voltage. The different frequency components result in the non-fundamental frequencies in the voltage and the current of a wind farm, which is called by "beats". This phenomenon requires considerable changes of control technologies of a WTG to improve the characteristics in the transient state such as a fault ride-through requirement of a wind farm. Moreover, it may cause difficulties in protection relays of a wind farm. This paper analyzes the response of a wind farm for various fault conditions using a PSCAD/EMTDC simulator.