• Title/Summary/Keyword: Power derating

Search Result 17, Processing Time 0.023 seconds

Power Design of an S-Band Transmitter for KSLV-II with Derating (디레이팅을 고려한 한국형발사체 S-밴드 송신기 전원부 설계)

  • Kim, Seokkwon;Kim, Sung-Wan;Hong, Seung Hyun;Kim, Hyo Jong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.5
    • /
    • pp.339-347
    • /
    • 2019
  • The power circuit design of an on-board S-band transmitter for KSLV-II with derating(operation of a component at less than its maximum rated specification to enhance reliability) is investigated. The power circuit of the transmitter consists of linear voltage regulators, DC/DC converters for regulating the DC supply, and diodes for reverse voltage protection. After analyzing the load current of the components, derating requirements are explored. Furthermore, power dissipation and junction temperature rise are considered with respect to the load current. The analysis is compared to the results from an engineering model of the transmitter. The temperature of the components is derated by >$40^{\circ}C$ in an environment where the ambient temperature is $+60^{\circ}C$, which is the acceptance test specification of high temperature.

Study on Thermal Vacuum Test Result of DCAMP by the Analysis of Derating & Gain Control (디지털중계기의 부하경감 및 이득조정기능 분석을 통한 열진공시험결과 성능분석)

  • Jin, Byoung-Il;Ko, Hyun-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.1
    • /
    • pp.72-78
    • /
    • 2015
  • Recently, the usage of the satellite is increased more and more in the areas that are communication, weather, marine, optical, radar etc. The functions of the Satellite are evolving from passive transponder to active transponder by the developing of a technology. Advanced countries in satellites install the DCAMP for increase of bandwidth efficiency, improvement of QoS by interference rejection. DCAMP includes many digital components in order to implement functions. Thus, these kinds of active transponders consume much more power compared to passive transponder and then increase the heat. In this paper, we discuss the TVAC test result of DCAMP in EQM(Engineering Qualification Model) level. The paper shows the test results of digital gain control in order to verify DCAMP status under the TVAC test. In addition, the temperature and heat condition of main components from viewpoint of derating will be treated through the official environment test for qualification.

Power Factor Correction Circuit For Inverter Air-Conditioner Using A Parallel Drive Method (병렬구동 방식을 이용한 인버터 에어컨용 역률제어회로)

  • 정용채;정윤철;권경안
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.9-12
    • /
    • 1998
  • In this paper, the power factor correction circuit using a parallel drive method is proposed so that the high power inverter air-conditioner with 3[ph] compressor motor may obtain the cost down and the improved performance. The adequate design procedures are presented to reduce the material costs by eliminating the power factor improving LC filter and derating output capacitor and inverter switches. Using the determined components, the prototype circuit with 6[kW] power consumption is built and tested to verify the operation of the proposed circuit.

  • PDF

The Effect of Overdesign on Titan Rocket Engine Reliability and Development Cost (과설계가 타이탄 로켓엔진의 신뢰도 및 개발비용에 미치는 영향)

  • Kim, Kyungmee O.;Hwang, Junwoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.4
    • /
    • pp.334-340
    • /
    • 2015
  • Engine derating is often considered for reliability benefits because lower power operation reduces its failure probability. To be derated during operation, however, the engine must be initially overdesigned. The engine overdesign is cost effective only if reliability increased from derating is enough to offset the initial increase in the development cost caused from the overdesign. The purpose of this paper is to provide an analytical model to consider a trade-off between the engine overdesign and derating. We use a logistic regression model to explain reliability growth in the number of hot firing tests for a fixed power level. Using the Transcost model with the reliability growth model, we show that 10% overdesign of Titan rocket engine decreases its development cost by about 9% and 23% depending on the reliability requirement. We also point out that such a cost reduction depends on the fuel type a rocket uses.

Experimental Verification of Heat Sink for FPGA Thermal Control (FPGA 열제어용 히트싱크 효과의 실험적 검증)

  • Park, Jin-Han;Kim, Hyeon-Soo;Ko, Hyun-Suk;Jin, Bong-Cheol;Seo, Hak-Keum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.9
    • /
    • pp.789-794
    • /
    • 2014
  • The FPGA is used to the high speed digital satellite communication on the Digital Signal Process Unit of the next generation GEO communication satellite. The high capacity FPGA has the high power dissipation and it is difficult to satisfy the derating requirement of temperature. This matter is the major factor to degrade the equipment life and reliability. The thermal control at the equipment level has been worked through thermal conduction in the space environment. The FPGA of CCGA or BGA package type was mounted on printed circuit board, but the PCB has low efficient to the thermal control. For the FPGA heat dissipation, the heat sink was applied between part lid and housing of equipment and the performance of heat sink was confirmed via thermal vacuum test under the condition of space qualification level. The FPGA of high power dissipation has been difficult to apply for space application, but FPGA with heat sink could be used to space application with the derating temperature margin.

Design of 1500V solar inverter stack beyond megawatt in NPC1 topology

  • Hao, Xin;Ma, Kwok-Wai;Zhao, Jia;Sun, Xin-Yu
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.7-11
    • /
    • 2017
  • This paper describes a design concept of NPC1 power stack for 1500VDC megawatt level solar inverter. This stack uses three latest half-bridge IGBT modules with highest power density and operation junction temperature, which enable realization of power level beyond 1MW without paralleling. Critical design concept on loop inductance is explained. Dynamic characteristics are verified by double-pulse test. Thermal characteristics and output power limits are verified by thermal test. Temperature-sensitive component on PCB as output power constraint is identified. Different PCB repositioning solutions are tested to give the overall output power thermal derating curves, which enable output power of 1.15MW at $T_A=55^{\circ}C$ with $15^{\circ}C$ thermal margin. The power stack characteristic and performance change under different thermal environment is further analyzed.

  • PDF

Power Factor Correction Circuit For Inverter Air-Conditioner With A Parallel Configuration To Reduce The Material Cost (재료비 절감을 위한 병렬구조를 갖는 인버터 에어컨용 역률제어회로)

  • 정용채;정윤철;권경안
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.122-127
    • /
    • 1999
  • In this paper, the power factor correction circuit using a parallel drive method is proposed so that the high power inverter air-conditioner with 3[hp] compressor motor may obtain the cost down and the improved performance. The adequate design porcedures are presented to reduce the material costs by eliminating the power factor imprving LC filter and derating output capacitor and inverter switches. Using the determined components. the proto-type circuit with 6[kW] power consumption is built and tested to verify the operation of the proposed circuit.

  • PDF

Analysis on the Operation Characteristics of Induction Motor Operated by Unbalanced Voltage with Harmonics Components (고조파 성분이 포함된 전압 불평형 운전시 유도전동기의 동작 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.3
    • /
    • pp.134-140
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are usually balanced and connected to three power systems. However, in the user power distribution systems, partial loads are single & three phase and unbalanced, generating voltage unbalance by the impedance mismatching. Voltage unbalance has detrimental effects on three-phase induction motors, including over heating, line-current unbalance, derating, torque pulsation, low efficiency, etc. This paper presents a scheme on operation states of a three-phase induction motor under the unbalanced voltages with harmonics components. Three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting not only fundamental but also harmonics components. Harmonic components at the voltage unbalanced factor(VUF) of the three-phase source voltages can then be examined the different values of VUF on machine's operation characteristics.

Feedwater Flow Rate Evaluation of Nuclear Power Plants Using Wavelet Analysis and Artificial Neural Networks (웨이블릿 해석과 인공 신경회로망을 이용한 원자력발전소의 급수유량 평가)

  • Yu, Sung-Sik;Seo, Jong-Tae;Park, Jong-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.346-353
    • /
    • 2002
  • The steam generator feedwater flow rate in a nuclear power plant was estimated by means of artificial neural networks with the wavelet analysis for enhanced information extraction. The fouling of venturi meters, used for steam generator feedwater flow rate in pressurized water reactors, may result in unnecessary plant power derating. The backpropagation network was used to generate models of signals for a pressurized water reactor. Multiple-input single-output heteroassociative networks were used for evaluating the feedwater flow rate as a function of a set of related variables. The wavelet was used as a low pass filter eliminating the noise from the raw signals. The results have shown that possible fouling of venturi can be detected by neural networks, and the feedwater flow rate can be predicted as an alternative to existing methods. The research has also indicated that the decomposition of signals by wavelet transform is a powerful approach to signal analysis for denoising.

  • PDF

The measurement & Analysis of Voltage Unbalance Factor at Three Phase Four Wire Load System (3상 4선식 부하설비의 전압 불평형율 측정 및 분석)

  • Kim, Jong-Gyeum;Park, Young-Jin;Lee, Dong-Ju;Lee, Hwa-Su;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.15-17
    • /
    • 2004
  • Most of LV customer has been composed the 3-phase four wire system distribution system which is supplying simultaneously at the 1-phase & 3-phase load. In this system, the composition of the power apparatus system is simple rather than conventional separation mode of the 1-phase & 3-phase, But due to uneven load unbalance or unclean power quality, various kinds such as derating or power losses become an issue. In this paper, we measured and analyzed voltage and current waveform in the field, compared with internationally allowable voltage unbalance limits.

  • PDF