• 제목/요약/키워드: Power compensator

검색결과 609건 처리시간 0.025초

3상 PWM 콘버어터에 의한 정지형 무효전력 보상장치의 동작특성 (Static VAR Compensator Using 3 Phase PWM converter)

  • 김철우;김광태;권순재;홍순일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.137-139
    • /
    • 1988
  • A reactive power compensator whitch employs a three phase voltage source PWM converter is presented and analysed in this study. In this study, instantaneous reactive power compensator by the theory of instantaneous real and imaginary power are theoretically studied how to compensate reactive power occured by fundamental and harmonic reactive current. And we showed the compensation characteristics by comparing the experimental results with those of computer simulation.

  • PDF

Line - Interactive UPS의 역률 개선 방안에 관한 연구 (A Study on the Line-Interactive UPS with Power Factor correction)

  • 장훈;이우철;이택기;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.93-96
    • /
    • 2001
  • This paper proposed on the Line-Interactive UPS with power factor correction. The paper Line-Interactive UPS topology with its advantages is reviewed. Next introduces Line -Interactive UPS of the series active compensator. The series active compensator controls input currents and power factor.

  • PDF

송전 전력 제어를 위한 분산 정지형 직렬 보상기에 관한 연구 (Distributed static series compensator based flexible AC transmission system)

  • 윤한종;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.29-30
    • /
    • 2016
  • This paper describes a distributed static series compensator (DSSC) which is a type of distributed flexible ac transmission system (DFACTS). The control principles including the power flow control and the current regulation are explained in detail. In order to verify the effectiveness of the DSSC, the simulation results are offered.

  • PDF

IPMSM 센서리스 제어에서의 속도리플저감 알고리즘에 관한 연구 (Study on Speed Ripple Reduction Algorithm in Sensorless Controlled IPMSM)

  • 이송철;정영석
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.249-253
    • /
    • 2016
  • In this study, a harmonic-pulsation-compensator (HPC) is presented to reduce a periodic speed ripple in IPMSM. A proportional-integral compensator in HPC is proposed instead of the existing integral compensator to reduce the speed ripple more rapidly. A formula to calculate a rotation angle is also proposed, making compensation optimal in sensored and sensorless controls. The validity of the proposed algorithm is verified by experiments.

Static Synchronous Series Compensator(SSSC) 댐핑 제어 및 해석모형 (Damping Control Strategy and Analysis Model of Static Synchronous Series Compensator(SSSC))

  • 김학만;전영환;오태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.509-515
    • /
    • 2000
  • This paper addresses a damping control strategy of Static Synchronous Series Compensator(SSSC) and analysis model for stability study. The effect of injected voltage source generated by SSSC is modelled as equivalent load. This model is thought to be reasonable for the stability study because the dynamics of SSSC is very fast compared with that of power system. Damping controller of SSSC is based on Transient Energy Function method. The proposed control strategy is insensitive to the operating conditions like power flow level because control law depends on the phase angles. The proposed analysis model and control strategy was confirmed by WSCC 9 bus system and two area system. Especially, the robustness of proposed control strategy is demonstrated with respect to multiple operating conditions in two area system.

  • PDF

싸이리스터 전류원인버터를 이용한 새로운 무효전력보상기 (New Reactive-Power Compensator using Thyristor Current-Source Inverter)

  • 백승택;한병문
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권4호
    • /
    • pp.219-225
    • /
    • 1999
  • This paper proposes a new reactive-power compensator composed of a thyristor current-source inverter. The compensator consists of a 6-pulse thyristor bridge, dc reactor, and a commutation circuit. The commutation circuit offers the thyristor bridge to have PWM operation with minimal switching losses. The operation of proposed system was analyzed by computer simulations with EMTP and experimental works with hardware scaled-model. The proposed system would have low cost and easy expansion of operation voltage due to using the conventional thyristors.

  • PDF

A Load Compensator Based on One-Cycle Control with Plug-In Repetitive Control

  • Hu, Jian;Sun, Zhaohui;Ma, Hao;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.443-454
    • /
    • 2015
  • This study proposes a novel one-cycle control scheme with a plug-in repetitive controller for load compensator. The novelty of this scheme lies in the combination of high dynamics and the simplicity of a one-cycle controller and good steady-state harmonic suppression ability of the repetitive controller. In addition, the proposed scheme can reduce the effect of the harmonics in phase voltage for the existence of the repetitive controller. Finally, experimental results on a three-phase, four-wire, three-level load compensator are reported to validate the effectiveness of the proposed control scheme.

A Hybrid Static Compensator for Dynamic Reactive Power Compensation and Harmonic Suppression

  • Yang, Jia-qiang;Yang, Lei;Su, Zi-peng
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.798-810
    • /
    • 2017
  • This paper presents a combined system of a small-capacity inverter and multigroup delta-connected thyristor switched capacitors (TSCs). The system is referred to as a hybrid static compensator (HSC) and has the functions of dynamic reactive power compensation and harmonic suppression. In the proposed topology, the load reactive power is mainly compensated by the TSCs. Meanwhile the inverter is meant to cooperate with TSCs to achieve continuous reactive power compensation, and to filter the harmonics generated by nonlinear loads and the TSCs. First, the structure and mathematical model of the HSC are discussed Then the control method of the HSC is presented. An improved reduced order generalized integrator (ROGI)-based selective current control method is adopted in the inverter to achieve high-performance reactive and harmonic current compensation. Meanwhile, a switch control strategy is proposed to implement precise and fast switching of the TSCs and to avoid changing the time delay needed by the conventional switch strategy. Experiments are implemented on a 20 KVA HSC prototype and the obtained results verify the validity of the proposed HSC system.

델터변조방식을 이용한 전류형 반도체 무효전력보상장치 (The Current Type Semiconductor Reactive Power Compensator Using Delta Modulation Method)

  • 박형래;김한성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.443-446
    • /
    • 1991
  • In the conventional current control methods for the current-type reactive power compensators, it is usual to compare the reactive reference current signal with the triangular wave and hence to generate the ON-OFF signals for the semiconductor reactive power compensator. To improve the response as well as the control capability, the delta modulated current control technique is proposed in this paper and studied theoretically.

  • PDF

배전용 정지형 보상기의 위상변이를 이용한 순시 유효/무효전력 보상 (Instantaneously Active/Reactive Power Compensation of Distribution Static Compensator using Phase Shift)

  • 홍성민;최종우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.468-469
    • /
    • 2010
  • DSTATCOM(Distribution STATic COMpensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Conventional researches use a LPF(Low Pass Filter) to eliminate ripple component at the calculation of compensation current. This paper proposes a calculation of compensation current using phase shift that can be a counterproposal of conventional methods using LPF.

  • PDF