• 제목/요약/키워드: Power arc test

검색결과 121건 처리시간 0.032초

GIS내에서 금속이물이 절연파괴에 미치는 영향 (The Effect of Conducting Particles on Breakdown Phenomena in GIS)

  • 김민규;문인옥;김윤택;김익수;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1574-1576
    • /
    • 1994
  • $SF_6$ gas has become an important insulation medium in modern electric power apparatus, because of its high insulation withstand levels and good arc quenching capability. For the application of $SF_6$ gas in GIS the estimation of insulation properties is a fundamental point. Moreover the reduction of withstand levels in case of inhomogeneous fields caused by particles or fixed protrusions is of special interest. It is known that the presence of free conducting particles in GIS can significantly lower the insulating level of $SF_6$ gas at elevated pressure and also it has been recently shown that dielectric strength is greatly reduced by fast transients such as disconnector surges where metallic particles are involved. In this paper, we have disigned the particle test chamber rated 362kV for the purpose of investigating the discharge characteristics in SF6 gas where inhomogenius fields are caused by metallic particles.

  • PDF

전차선로 속도향상에 따른 오버랩 구간(Overlap section) 경간 구성 기법 (Research on Configuration Optimization of Overlap Section in Overhead Catenary System for High-speed Railway)

  • 최태수;최규형
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.975-980
    • /
    • 2017
  • Overhead catenary system of electric railway has overlap sections which devide and tighten trolley wire supplying electric power to train, where current collection performances may become worse according to railway speed-up. Current collection tests conducted at 400 km/h test-bed section of Honam high-speed railway show that balanced line arrangement at overlap section is needed to secure current collection without arc generation between trolley wire and train current collection device. This paper proposes a design procedure of the overlap section to allow for tension increase and uplift of the trolley wires according to railway speed-up. By applying the proposed procedure to the overhead catenary system of Honam high-speed railway, it is suggested that the minimum span length should be 33.2 m for railway speed-up to 350 km/h and 43.7 m for speed-up to 400 km/h.

삼상 교류 플라즈마 발생의 안정화 (Stabilization of Plasma in a Three-Phase AC Plasma Generator)

  • 이경호;김광수;이홍식;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.209-211
    • /
    • 2002
  • A simple-structured thermal plasma generator for waste gas treatment has been studied. The thermal plasma technology applied to waste treatment has undoubtedly gained high importance owing to its outstanding properties such as flexibility, compact reactor, and clean treatment. Moreover, the thermal plasma generated by ac power has some additional advantages such as simple electrode system and easy maintenance. A prototype 200kW class plasma generator with specifications of 10-30m/sec gas velocity and 3000-5000K temperature on the center just outside of the nozzle has been designed and tested. Case studies on heat transfer, heat flow, velocity distribution, and temperature distribution using a commercial simulation package show lots of flexibility in design. The experimental results from theprototype generator show that the ac thermal plasma is easily controlled by working gas flow once it is ignited. A stabilization condition is discussed with the data from monitoring arc voltage drops with respect to gas flow rate during the test.

  • PDF

직류전기철도의 누설전류 간섭대책(3) 누설전류 포집시스템 (Mitigation of Stray Current Interference from DC Electric Railroad(3) Stray Current Confinement Method)

  • 하윤철;배정효;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.276-278
    • /
    • 2005
  • For over 25 years, the stray currents from DC electric railroads have caused serious interference problems with underground metallic infrastructures in Korea. The most serious interference is reported at the pipelines near the depot areas. Our field survey proves that this phenomena is mainly due to the missing of dedicated rectifiers for mainline, depot and/or workshop areas. Because it takes so much time and costs too much to replace the traction power system, we consider a stray current confinement method which collects the stray currents and drains them to the negative terminal of the rectifier. This can be realized by installing a stray current collecting wire along the depot boundary. Moreover, we found the stray current collecting reinforcement bar located beneath the rails of concrete slab tracks. Using this bar, we arc going to draing the stray currents from mainline rails. In this paper we show the result of field survey on railroad facilities and present the stray current confinement method under field test.

  • PDF

전철 탑재형 피뢰기의 모듈설계 및 성능평가기술 (Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock)

  • 조한구;김석수;한세원;이운응
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

전철 탑재용 피뢰기의 설계 및 성능평가 (Design and Performance Evaluation of Surge Arrester for Loading in Railway Rolling Stock)

  • 조한구;한세원;이운용;김석수;장태봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.74-77
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock. pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

단락용량 증대를 통한 슬림형 공항 분전반용 누전 차단기 개발 (Development of Silm Type ELCB For Airport Distribution Panel through Increased short Circuit Capacity)

  • 주남규;이종명;김남호
    • 한국항행학회논문지
    • /
    • 제16권2호
    • /
    • pp.360-366
    • /
    • 2012
  • 공항과 같은 산업 설비에 사용되는 분전반에서는 주 개폐기로 배선용 차단기가 사용이 되고 있으며, 분기 개폐기는 누전 차단기가 사용되어 인체 보호 및 누전 화재 보호 기능을 수행하고 있을 뿐만 아니라, 과전류 보호, 단락 보호 겸용 기능을 포함하여 사용되어 지고 있다. 특히 공항용 분전반의 경우 사용자의 급증과 함께 급속한 첨단화와 기기의 대용량화, 다양화, 전원용량의 증대 등으로 공항의 안정적인 전원 공급을 위하여 사고에 대한 보호 증대가 필요하게 되었고, 분기 누전 차단기의 다량 사용에 의한 2열 배열의 접속 방법 등으로 분전반을 제작하여 설치 면적에 대한 이슈가 부각되어 차단기의 슬림화가 주요한 문제로 자리 잡고 있다. 본 논문에서는 이를 위하여 아크 소호 기구부의 설계, 접점이 운동 방향 변경을 고려하여 기구부를 설계하고, 누전 검출 회로의 소형화 및 역 접속 시에도 안적적인 동작이 가능하도록 설계하였으며, 이를 검증하기 위하여 단락 시험을 실시함으로써 성능 검증을 하였고, 사고 전류에 대한 보호 기능의 강화와, 차단기의 슬림화, 역접속시에서 누전 동작이 가능한 차단기를 개발함으로써 급속히 커져가는 공항용 분전반에서 발생하는 공간 사용의 문제점을 해결하는데 도움을 주고자 한다.

통전전류 특성을 이용한 모터 기동용 전해 커패시터 폭발 방지 방법 (The Explosion Prevention Method for Electrolytic Motor Start Capacitors using Current Characteristic)

  • 김재현;박진영;박광묵;방선배;김용운
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1836-1843
    • /
    • 2017
  • In this paper, we investigated fire cases those are believed to be caused by explosion of a electrolytic motor start capacitor. Using two types of commercially available electrolytic motor start capacitors, capacitor current and the possibility of capacitor explosion were tested. And the ignition possibility of the internal material leaked from a capacitor was also tested. In addition, experiments were conducted to see if the fire could spread when a capacitor was exposed to an external flame. From our test we observed that the current of the electrolytic motor start capacitor rose continuously to a certain level by product, if the capacitor was continuously energized with working voltage, and then the capacitor was exploded. The gas and liquid leaked from the capacitor by the explosion could ignite by an electric arc and an external flame. The capacitor current at explosion was different product by product, but each product had a certain current level at explosion. And the increase rate of the capacitor current until explosion was 24% and 31% for the products used in the experiment. We proposed the capacitor explosion prevention method that cuts off power when the capacitor current rises to a certain threshold level. The proposed method can be used if the current of the applied electrolytic motor start capacitor rises continuously and then the capacitor is exploded at a certain current level when the capacitor is energized continuously.

ALD-Al2O3 보호층이 적용된 CrAlSiN 코팅막의 내부식성 특성에 관한 연구 (Effect of ALD-Al2O3 Passivation Layer on the Corrosion Properties of CrAlSiN Coatings)

  • 만지흠;이우재;장경수;최현진;권세훈
    • 한국표면공학회지
    • /
    • 제50권5호
    • /
    • pp.339-344
    • /
    • 2017
  • Highly corrosion resistance performance of CrAlSiN coatings were obtained by applying ultrathin $Al_2O_3$ thin films using atomic layer deposition (ALD) method. CrAlSiN coatings were prepared on Cr adhesion layer/SUS304 substrates by a hybrid coating system of arc ion plating and high power impulse magnetron sputtering (HiPIMS) method. And, ultrathin $Al_2O_3$ passivation layer was deposited on the CrAlSiN/Cr adhesion layer/SUS304 sample to protect CrAlSiN coatings by encapsulating the whole surface defects of coating using ALD. Here, the high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) and energy dispersive X-ray spectrometry (EDX) analysis revealed that the ALD $Al_2O_3$ thin films uniformly covered the inner and outer surface of CrAlSiN coatings. Also, the potentiodynamic and potentiostatic polarization test revealed that the corrosion protection properties of CrAlSiN coatings/Cr/SUS304 sample was greatly improved by ALD encapsulation with 50 nm-thick $Al_2O_3$ thin films, which implies that ALD-$Al_2O_3$ passivation layer can be used as an effect barrier layer of corrosion.

Aerodynamic analysis on the step types of a railway tunnel with non-uniform cross-section

  • Li, Wenhui;Liu, Tanghong;Huo, Xiaoshuai;Guo, Zijian;Xia, Yutao
    • Wind and Structures
    • /
    • 제35권4호
    • /
    • pp.269-285
    • /
    • 2022
  • The pressure-mitigating effects of a high-speed train passing through a tunnel with a partially reduced cross-section are investigated via the numerical approach. A compressible, three-dimensional RNG k-ε turbulence model and a hybrid mesh strategy are adopted to reproduce that event, which is validated by the moving model test. Three step-like tunnel forms and two additional transitions at the tunnel junction are proposed and their aerodynamic performance is compared and scrutinized with a constant cross-sectional tunnel as the benchmark. The results show that the tunnel step is unrelated to the pressure mitigation effects since the case of a double-step tunnel has no advantage in comparison to a single-step tunnel, but the excavated volume is an essential matter. The pressure peaks are reduced at different levels along with the increase of the excavated earth volume and the peaks are either fitted with power or logarithmic function relationships. In addition, the Arc and Oblique-transitions have very limited gaps, and their pressure curves are identical to each other, whereas the Rec-transition leads to relatively lower pressure peaks in CPmax, CPmin, and ΔCP, with 5.2%, 4.0%, and 4.1% relieved compared with Oblique-transition. This study could provide guidance for the design of the novel railway tunnel.