• Title/Summary/Keyword: Power Regulator

Search Result 497, Processing Time 0.021 seconds

Highly power-efficient and reliable light-emitting diode backlight driver IC for the uniform current driving of medium-sized liquid crystal displays

  • Hong, Seok-In;Nam, Ki-Soo;Jung, Young-Ho;Ahn, Hyun-A;In, Hai-Jung;Kwon, Oh-Kyong
    • Journal of Information Display
    • /
    • v.13 no.2
    • /
    • pp.73-82
    • /
    • 2012
  • In this paper, a light-emitting diode (LED) backlight driver integrated circuit (IC) for medium-sized liquid crystal displays (LCDs) is proposed. In the proposed IC, a linear current regulator with matched internal resistors and an adaptive phase-shifted pulse-width modulation (PWM) dimming controller are also proposed to improve LED current uniformity and reliability. The double feedback loop control boost converter is used to achieve high power efficiency, fast transient characteristic, and high dimming frequency and resolution. The proposed IC was fabricated using the 0.35 ${\mu}m$ bipolar-CMOS-DMOS (BCD) process. The LED current uniformity and LED fault immunity of the proposed IC were verified through experiments. The measured power efficiency was 90%; the measured LED current uniformity, 97%; and the measured rising and falling times of the LED current, 86 and 7 ns, respectively. Due to the fast rising and falling characteristics, the proposed IC operates up to 39 kHz PWM dimming frequency, with an 8-bit dimming resolution. It was verified that the phase difference between the PWM dimming signals is changed adaptively when LED fault occurs. The experiment results showed that the proposed IC meets the requirements for the LED backlight driver IC for medium-sized LCDs.

A Design of Integrated Circuit for High Efficiency current mode boost DC-DC converter (고효율 전류모드 승압형 DC-DC 컨버터용 집적회로의 설계)

  • Lee, Jun-Sung
    • 전자공학회논문지 IE
    • /
    • v.47 no.2
    • /
    • pp.13-20
    • /
    • 2010
  • This paper describes a current mode PWM DC-DC converter IC for battery charger and supply power converter for portable electronic devices. The maximum supply voltage of IC is 40[V] and 2.8[V]~330[V] DC input power is converted to higher or programmed DC voltage according to external resistor ratio or wire winding ratio of transformer. The maximum supply output current is 3[A] over and voltage error of output node is within 3[%]. The whole circuit needed current mode PWM DC-DC converter circuit is designed. The package dimensions and number of external parts are minimized in order to get a smaller hardware size. The power consumption is smaller then 1[mW] at stand by period with supply voltage of 3.6[V] and maximum energy conversion efficiency is about 86[%]. This device has been designed in a 0.6[um] double poly, double metal 40[V] CMOS process and whole chip size is 2100*2000 [um2].

소형위성 ETB에서의 전력계 기능시험

  • 윤영수;박종오;최종연;권재욱;안재철;조승원;김영윤
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.91-91
    • /
    • 2003
  • 위성을 발사하기 전까지는 지상에서 EGSE(Electrical Ground Support Equipment)를 이용하여 충분한 시스템 단위의 위성체 기능 시험을 수행한다. KOMPSAT-2(Korea Multi-Purpose Satellite - 2)와 같은 소형 위성의 서브시스템 각각이 요구사항에서 제시하는 규격을 만족하는지 여부를 점검하는 단계에서 전력계 관련 서브시스템의 기능 시험도 EPS(Electrical Power Subsystem) Test Plan에 의해 순차적으로 수행한다. KOMPSAT-2 ETB(Engineering Test Bed)에서의 전력계 시험은 먼저 Test Fuse Modules Check를 수행하였다. 퓨즈 모듈은 PCU(Power Control Unit) 상에 설치되어 있는 장치로써 퓨즈 모듈의 입력과 출력 사이에 도통성 및 다른 출력과의 절연성을 검증한다. 다음으로 EGSE 중 PMTS(Power Monitor Test Set)와 PCU와의 직렬 인터페이스를 점검하는 PCU Interface Check를 수행하였다 시험절차서에 따라 PCU가 가지는 릴레이 스위치에 대하여 명령어를 보내어 릴레이의 동작 상태 및 출력 전압 등을 점검한다. 다음 단계에서는 DC Integration을 수행하여 ETB 하니스 중 전원 관련 라인을 점검하였다 PCU는 모든 위성체 하드웨어에 전력을 공급하는 장비로써 과전력으로부터 하드웨어를 보호하기 위하여 하니스를 연결하기 전에 우선적으로 시험한다. 다음으로는 ECU(EPS Control Unit)가 각각에 해당하는 하드웨어에 명령어를 보내어 전력계 전체적인 동작 상태 검증하는 EPS Hardware Command & Telemetry Checkout을 수행하였다. ECU는 전력계의 모든 하드웨어를 제어하고 그 상태를 모니터링하는 기능을 한다. PCU와의 인터페이스를 통하여 전력의 제어 및 분배에 관련되는 특성을 제어 및 모니터하며 DDC(Deploy Device Controller)는 ECU로부터 명령어를 받아서 arm 및 safe 상태에 대한 텔리 메트리 데이터를 제공한다 그리고, SAR(Solar Array Regulator)는 ECU로부터 Bypass Relay 및 ARM Relay에 관한 명령어를 받아 수행되며 그에 따른 텔리 메트리 데이터를 제공한다. 마지막으로 EPS 소프트웨어를 검증하는 EPS Software Verification을 수행하였다 전력계 소프트웨어의 설계의 검증 부분은 현재 설계 제작된 전력계 .소프트웨어의 동작 특성 이 위성 의 전체 운용개념과 연계하여 전력계 소프트웨어가 전력계 및 위성체의 요구조건을 만족시키는지를 확인하는데 있다. 전력계 운용 소프트웨어는 배터리의 충ㆍ방전을 효율적으로 관리해 3년의 임무 기간동안 위성체에 전력을 공급할 수 있도록 설계되어 있다

  • PDF

Application of Adaptive Control Theory to Nuclear Reactor Power Control (적응제어 기법을 이용한 원자로 출력제어)

  • Ha, Man-Gyun
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.336-343
    • /
    • 1995
  • The Self Tuning Regulator(STR) method which is an approach of adaptive control theory, is ap-plied to design the fully automatic power controller of the nonlinear reactor model. The adaptive control represent a proper approach to design the suboptimal controller for nonlinear, time-varying stochastic systems. The control system is based on a third­order linear model with unknown, time-varying parameters. The updating of the parameter estimates is achieved by the recursive extended least square method with a variable forgetting factor. Based on the estimated parameters, the output (average coolant temperature) is predicted one-step ahead. And then, a weighted one-step ahead controller is designed so that the difference between the output and the desired output is minimized and the variation of the control rod position is small. Also, an integral action is added in order to remove the steady­state error. A nonlinear M plant model was used to simulate the proposed controller of reactor power which covers a wide operating range. From the simulation result, the performances of this controller for ramp input (increase or decrease) are proved to be successful. However, for step input this controller leaves something to be desired.

  • PDF

A Study on The Design of China DSRC System SoC (중국형 DSRC 시스템 SoC 설계에 대한 연구)

  • Shin, Dae-Kyo;Choi, Jong-Chan;Lim, Ki-Taeg;Lee, Je-Hyun
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • The final goal of ITS and ETC will be to improve the traffic efficiency and mobile safety without new road construction. DSRC system is emerging nowadays as a solution of them. China DSRC standard which was released in May 2007 has low bit rate, short message and simple MAC control. The DSRC system users want a long lifetime over 1 year with just one battery. In this paper, we propose the SoC of very low power consumption architecture. Several digital logic concept and analog power control logics were used for very low power consumption. The SoC operation mode and clock speed, operation voltage range, wakeup signal detector, analog comparator and Internal Voltage Regulator & External Power Switch were designed. We confirmed that the SoC power consumption is under 8.5mA@20Mhz, 0.9mA@1Mhz in active mode, and under 5uA in power down mode, by computer simulation. The design of SoC was finished on Aug. 2008, and fabricated on Nov. 2008 with $0.18{\mu}m$ CMOS process.

Laparoscope Manipulator Control for Minimally Invasive Surgery (최소침습수술을 위한 복강경 매니퓰레이터 제어)

  • Kim, Soo-Hyun;Kim, Kwang-Gi;Jo, Yung-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.7
    • /
    • pp.685-696
    • /
    • 2011
  • An efficient laparoscope manipulator robot was designed to automatically control the position of laparoscope via a passive joint on end-effector position. The end position of the manipulator is controlled to have corresponding velocity defined in the global coordinate space using laparoscopic visual information. Desired spatial position of laparoscope was derived from detected positions of surgical instrument tips, then the clinical viewing plane was moved by visual servoing task. The laparoscope manipulator is advantageous for automatically maintaining clinically important views in the laparoscopic image without any additional operator. A laparoscope is mounted to a holder which is linked to four degree of freedom manipulator via universal joint-type passive rings connection. No change in the design of laparoscope or manipulator is necessary for its application to surgery assistant robot system. Expanded working space and surgical efficiency were accomplished by implementing slant linking structure between laparoscope and manipulator. To ensure reliable positioning accuracy and controllability, the motion of laparoscope in an abdominal space through trocar was inspected using geometrical analysis. A designed laparoscope manipulating robot system can be easily set up and controlled in an operation room since it has a few subsidiary devices such as a laparoscope light source regulator, a control PC, and a power supply.

A Design and Voltage Control of a High Efficiency Generator with PM Exciter (고효율 영구자석 여자기 구조의 발전기 설계와 전압제어)

  • Jo, YeongJun;Lee, Dong-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1827-1834
    • /
    • 2016
  • This paper presents a high efficient generator with PM(Permanent Magnet) exciter. The proposed PM exciter for the generator can produce a linear output voltage according to the engine speed. This output voltage is directly used to control the field current of the generator to adjust the generator output voltage. In the proposed generator system, since the field winding current can be supplied by the PM exciter, the generator can self-start without any battery or an external power supply due to the low residential flux. Furthermore, the operating efficiency of the generator is higher than a conventional winding exciter. The main problem of the proposed generator system, the field winding current controller has to be embedded inside the generator, and it rotates according to the generator shaft. In this paper, the proper embedded current controller is designed for the proposed generator system. Due to the embedded controller cannot be connected to the outside the generator controller, the measured instantaneous output voltage of the generator is transferred by the photo isolated communication using shaft aligned infrared transmitter and receiver to keep the constant generator output voltage. In this paper, 10kW, 380V engine generator with PM exciter and the embedded DAVR(Digital Automatic Voltage Regulator) are described. The proposed high efficiency generator is simulated and tested to verify the effectiveness.

A Voltage Control Method based on Constants of Four Terminals Network Modeling of Distribution Networks

  • Yang, Xia;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Kim, Tae-Wan
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.354-362
    • /
    • 2008
  • In this paper, a new algorithm of optimal voltage control is proposed for the Distribution Automation System (DAS) based on constants of four terminal network modeling. In the proposed method, the voltage profiles along feeders are estimated from the measurement of the current and power factor by a Feeder Remote Terminal Unit (FRTU) installed at each node. Whenever the voltage profile violates the restriction, the voltage control strategy is applied to keep the voltage levels along the feeders within the pre-specified range through the modification and coordination of the transformer under-load tap changers (ULTC), step voltage regulator (SVR), as well as shunt condenser. In the case studies, the estimation and control of the voltages have been testified in a radial distribution system with 11 nodes.

The Business Alteration for Tobacco Farmers: Lessons from Rural Area in Indonesia

  • SEDYATI, Retna Ngesti;DJATMIKA, Ery Tri;WAHYONO, Hari;UTOMO, Sugeng Hadi
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.6 no.4
    • /
    • pp.281-286
    • /
    • 2019
  • The study aims to analyze the adaptation strategies and resilience of tobacco farmers to face unfavorable trading system. The research method refers to a qualitative approach with phenomenological models and case studies. The findings revealed tobacco farmers in Jember developed various adaptation strategies and resilience through farmer group organizations, partnerships, self-capacity building and access to financial institutions based on economic, social, cultural, and experience values from various sources and interactions among fellow tobacco farmers. The tobacco trading system, which is left to the market mechanism, results in low bargaining power of farmers, this encourages tobacco farmers to develop various adaptation and survival strategies, namely through collective activities of farmer groups, partnerships and self-development and access to financial institutions. Dealing with the unfavorable tobacco trading system, tobacco farmers do not switch to other commodity farming but adapt and make Jember a center for tobacco production in East Java and Indonesia. From this findings, it suggests to the government as the regulator does not only provide subsidies for tobacco farmers, but also must provide various technical assistance to increase the ability of tobacco farmers. More importantly, regulations must be made benefit tobacco farmers other than corporations so that equality can be enjoyed by tobacco economy players.

A Study on the Output Characteristics of AC Chopper Duty-Ratio $CO_2$ Laser System using 3 Electrode-type and Ring Blower (AC Chopper 3전극 방식의 듀티비에 따른 $CO_2$ 레이저 출력 특성에 관한 연구)

  • Park, Sung-Joon;Chung, Hyun-Ju;Kim, Geun-Yong;Lee, Yoo-Su;Kim, Whi-Young;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1697-1699
    • /
    • 2001
  • In this paper, the circuit of AC Choppers for $CO_2$ laser power supply are proposed and investigated. IGBT-controlled ac voltage regulators, operating at high frequency chopping mode. Chopping-to-supply duty ratio plays an important role in terms of laser output. Laser input energy is varied by controlling the leakage transformer used with the proposed system. This improved circuit employs a 3 electrode - type and Ring Blower. This improved circuit system has many advantages compared with the conventional SMPS such as simple design requirement, easy implementation, high reliability, low switching loss, and consequently high efficiency. As a result, the maximun output was 16W at duty-ratio of 92%, total gas mixture of $CO_2$ : $N_2$ : He = 1 : 9 : 15, total pressure of 15torr.

  • PDF