• 제목/요약/키워드: Power ON/OFF

검색결과 2,099건 처리시간 0.028초

고전압 차단기용 솔레노이드 액추에이터의 거동 (Behavior of the Solenoid Actuator for High-Voltage Circuit Breaker)

  • 윤소남;함영복;안병규;김고도
    • 유공압시스템학회논문집
    • /
    • 제1권3호
    • /
    • pp.1-6
    • /
    • 2004
  • In the last few years, a considerable number of studies have been made on On-Off solenoid for fluid control. But, only few attempts have so far been made at solenoid actuator for high-voltage circuit breaker. In case of the high-pressure and high-flow system like high-voltage circuit breaker, a big size of On/Off solenoid is necessary which size is proportional to control pressure and flow rate. So, it is non-effective in the view point of system optimization. In this paper, On/Off solenoid actuator with the farce amplifier connected to the solenoid rod was proposed to get a high mechanical force and a fast response time. The magnetic force and the mechanical stress distributions were analysed using finite element analysis. The performances of suggested solenoid actuator were evaluated through the experimental results and compared with the analysis results.

  • PDF

대용량 터빈발전기 고정자 권선의 정지중 및 운전중 부분방전 특성 (Off-Line and On-Line Partial Discharge Properties of Large Turbine Generator)

  • 김희동;이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1846-1849
    • /
    • 2000
  • Off-line and on-line partial discharges were measured on a 828MVA, 22kV and direct hydrogen-cooled large turbine generator. Partial discharge tests were conducted using digital partial discharge detector(PDD) and turbine generator analyzer(TGA). PDD and TGA showed that off-line partial discharge pattern seems to be very, similar to that found with on-line. Most of the partial discharge is originating with the stator slot in the three phases. As the partial discharge activity is very low, the stator insulation condition of this generator is very good.

  • PDF

가전제품 전력 사용 분류를 위한 장단기 메모리 기반 비침입 부하 모니터링 기법 (Non-Intrusive Load Monitoring Method based on Long-Short Term Memory to classify Power Usage of Appliances)

  • 경찬욱;선준호;선영규;김진영
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권4호
    • /
    • pp.109-116
    • /
    • 2021
  • 본 논문은 분산자원 집합 거래시장의 활성화와 에너지 관리의 중요성이 증가되면서 에너지 관리 모니터링 기술로서 합산된 전체 전력으로부터 각각의 가전제품의 전력을 찾아내는 비 침입 부하 모니터 기법을 제안한다. 본 논문에서는 데이터 전처리를 통해 각 가전제품들의 power on-off상태가 나오도록 한다. 이러한 데이터를 LSTM을 모델로 사용하여 각 가전제품들의 power on-off 상태를 예측한다. 예측한 상태들을 데이터 후처리를 한 후, 실제 상태들과 비교하여 정확도를 측정한다. 본 논문에서는 전자제품의 개수, 데이터 후처리 방법과 Time step size를 다르게 하여 정확도를 측정하여 비교한다. 전자 제품의 개수가 6개이고, Round함수로 데이터 후처리 방법을 사용하고, Time step size는 6으로 설정하였을 때, 가장 높은 정확도가 나온 것으로 측정되었다.

A Sensorless Switched Reluctance Drive System Based on the Improved Simplified Flux Method

  • Li, Zhenguo;Song, Andong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.477-482
    • /
    • 2012
  • This paper describes a new rotor position sensorless control method for SRM drives based on an improved simplified flux linkage method. In the traditional simplified flux linkage method, every phases take turns conduction and current chopping control method is used. Every phases take turns conduction means turning on the incoming working phase while turning off the working phase. This conduction mode causes coupling between turn-on and turn-off angles, which goes against optimal efficiency or torque ripple minimization with sensorless speed control. In the improved simplified flux linkage method, turn-off angle is calculated by flux loop, the turn-on angle can be given arbitrarily and has no relations with the turn-off angle, and the current chopping control method is used. The speed and rotor position can be estimated then. Finally, a sensorless SRM speed control system and an experiment platform with DSP are built and validity of this method is confirmed.

SRM 컨버터에서 자기동조 방식에 의한 턴오프 각의 결정 (Determination of Optimal Turn-off Angle for SRM Converter Using Self-Tuning Method)

  • 장도현;문진영
    • 전력전자학회논문지
    • /
    • 제3권4호
    • /
    • pp.418-425
    • /
    • 1998
  • 본 논문에서는 위상각 제어에서 주어진 턴온 각에서 최대의 토크를 유지하기 위한 적절한 턴오프 각을 자기동조방식(self-tuning method)에 의해 결정하는 방식을 제안하였다. 엔코더에 의해 샘플링 시간(sampling time)동안 구해진 펄스 수는 바로 이전의 샘플링시간 동안 구해진 펄스 수와 비교하여 턴오프 각을 앞으로 또는 뒤로 이동한다. 이러한 과정을 되풀이함으로서 최대 토크를 발생하는 턴오프 각을 결정하게 된다. 실제 회로에서는 원 칩 마이크로프로세서에 의해 처리되었으며 실험을 통해 턴온 각이 변하더라도 자기동조방식에 의해 턴오프 각을 조정하면 빠른 속도가 유지됨을 보여 주었다.

  • PDF

마이크로 솔레노이드의 해석 및 설계 (Analysis and Design of Micro Solenoid)

  • 전용식;배상규;김동수
    • 유공압시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.14-20
    • /
    • 2006
  • Recently, the on-off solenoid valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for on-off solenoid valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate on-off solenoid valve using the analogy of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, flow field characteristics was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D simulation using distribution curve of the force by working the front poppet.

  • PDF

근거리 무선통신(NFC) 기반의 대기전력 차단 클라이언트 설계 (Design of Standby Power Shut-off Client Based on Near Field Communication)

  • 전중창;노진송;최경선
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.978-980
    • /
    • 2013
  • 본 연구에서는 멀티탭에 근거리 무선통신(NFC) 모듈을 접목한 대기전력 차단 클라이언트 시스템의 개념을 제안하고, 클라이언트 시스템의 기본적인 하드웨어 구성과 소프트웨어 제어 개념도를 제시하였다. 이 시스템은 가정, 중/대형 사무실, 학원, 공장, 아파트 단지, 하우스 등 근거리통신을 이용하여 통합제어가 필요한 장소에 적용가능하다. 대기전력 관리 및 전력사용량 관리를 통하여 사무/가전기기들의 대기전력을 제어하여서 소비되는 총 전력을 줄이고, 전력 에너지 및 비용을 절감하는 효과가 기대된다.

  • PDF

Digital Sequence CPLD Technology Mapping Algorithm

  • Youn, Choong-Mo
    • Journal of information and communication convergence engineering
    • /
    • 제5권2호
    • /
    • pp.131-135
    • /
    • 2007
  • In this paper, The proposed algorithm consists of three steps. In the first step, TD(Transition Density) calculation has to be performed. a CLB-based CPLD low-power technology mapping algorithm considered a Trade-off is proposed. To perform low-power technology mapping for CPLDs, a given Boolean network has to be represented in a DAG. Total power consumption is obtained by calculating the switching activity of each node in a DAG. In the second step, the feasible clusters are generated by considering the following conditions: the number of inputs and outputs, the number of OR terms for CLB within a CPLD. The common node cluster merging method, the node separation method, and the node duplication method are used to produce the feasible clusters. In the final step, low-power technology mapping based on the CLBs packs the feasible clusters. The proposed algorithm is examined using SIS benchmarks. When the number of OR terms is five, the experiment results show that power consumption is reduced by 30.73% compared with TEMPLA, and by 17.11 % compared with PLA mapping.

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제25권3호
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.

ON/OFF 조정장치의 운동 양립성에 관한 연구 (Movement Compatibility of ON/OFF Controls)

  • 정병용;이정욱
    • 산업공학
    • /
    • 제14권3호
    • /
    • pp.302-309
    • /
    • 2001
  • Direction-of-motion stereotypes between ON/OFF controls were tested using a paper-and-pencil test and interview method. One hundred and forty eight subjects of both genders and from a wide range of ages were asked to indicate the control movement they would make to turn on the light. Stereotypes were obtained for nine types of ON/OFF controls in two different planes. The results show that stereotype for left-right power switches is right for on, and stereotype for up-down switches is up. And, a strong stereotype was found in the case of left-right switches than up-down switches. Some stereotypes are significantly different between genders and age groups. These findings identified in this study can be used to design the ON/OFF switches of the facilities and equipments.

  • PDF