• Title/Summary/Keyword: Power Measurement

Search Result 4,625, Processing Time 0.03 seconds

Algorithm of Harmonic State Estimation for Power Systems (전력시스템 고조파 상태추정알고리즘 개발)

  • Wang, Y.P.;Chong, H.H.;Chong, J.W.;Han, H.H.;Kwak, N.H.;Jeon, Y.S.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.149-150
    • /
    • 2006
  • The design of a measurement system to perform Harmonic State Estimation (HSE) is a very complex problem. In particular, the number of harmonic instruments available is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents a new HSE algorithm which is based on an optimal placement of measurement points using Intelligent Algorithms (IAs). This HSE has been applied to the Simulation Test Power System for the validation of the new HSE algorithm. The study results have indicated an economical and effective method for optimal placement of measurement points using Intelligent Algorithms (IAs) in the Harmonic State Estimation(HSE).

  • PDF

Cause Analysis of Level Measurement Error in Steam Generator of Nuclear Power Plant (원자력발전소의 증기발생기 수위계측 오차 원인분석)

  • Lee, Kwang-Dae;Oh, Eung-Se;Yang, Seung-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.591-593
    • /
    • 2006
  • The differential pressure method has been used in the level measurement of steam generator in nuclear power plant. Two sensing lines from a steam generator to a pressure transmitter are needed to measure the high pressure and low pressure. The fluid conditions in the sensing line require the uniform phase with no bubbles and the slope of sensing line should be installed with forward slope. The expansion of the bubble volume according to the upper pressure and the reverse slope of sensing lines explain how the level errors took place.

  • PDF

Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier

  • Yoo, Sun-K.
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.5
    • /
    • pp.601-605
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

The research of the UWB system radiation measurement (UWB 시스템의 방사출력 측정방법 연구)

  • Song, Hong-Jong;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.277-286
    • /
    • 2010
  • In this paper we analyse radiation measurement method for UWB wireless system of the wideband low power frequency characteristics. In the radiation measurement environment we discuss RMS electric field strength, UWB PSD, UWB detect signal level, UWB noise signal collection etc.. also, we discuss power measure method of the CISPR16-1, low level e.i.r.p radiation measurement method. lastly we analyse consideration problem for the signal analyser of the UWB system.

Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats (육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가)

  • Kim, Jae-Gone;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.525-532
    • /
    • 2011
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of meats, which could be an alterative of subjective measurements of human nose and time-consuming measurements of conventional gas chromatograph methods. The portable electronic system was o optimized by comparing the measurement sensitivity and hardware efficiency, such as power consumption and dimension reduction throughout two stages of the prototypes. The electronic nose systems were constructed using an array of four different metal oxide semiconductor sensors. Two different configurations of sensor array with dimension were designed and compared the performance respectively. The final prototype of the system showed much improved performance on saving power consumption and dimension reduction without decrease of measurement sensitivity of pork freshness. The results show the potential of constructing a portable electronic system for the measurement of meat quality with high sensitivity and energy efficiency.

A Study of Overall Measurement System for the Power dispersed High Speed Railway with 400km/h of Maximum Test Speed (최고시험속도 400km/h 동력분산형 고속철도의 종합계측시스템 구성 방안 연구)

  • Lee, Young-Yeob;Ryu, Sang-Hyun;Kim, Bong-Rae;Lee, Jun-One
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1785-1790
    • /
    • 2010
  • This study examined the overall measurement system for the power dispersed high speed railway with 400km/h of maximum test speed. The measuring system evaluating an efficiency, stability and reliability is important for developing the high speed railway. In order to organize the comprehensive measuring system, it is needed to determined the test item, a number of channel and the specifications of the measurement system. In this study, we made lists for the performance evaluation tests of the next generation high speed railway expected to be developed in the future, and prepared generalization channel sheets for the specification of the overall measurement system. In addition, the specifications for the measuring system were discussed and synthesized.

  • PDF

A Study of the Real-time Sensing by the Optical Current Sensor for GIS

  • Park, Won-Zoo;Kim, Yeong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.75-80
    • /
    • 2009
  • In this study, a Web server was constructed using LabVIEW's DataSocket, which makes possible acquisition, analysis, and saving in real time. The output value of the optical current sensor at the web server PC was measured and the output value was displayed using the Web browser of the client PC. DataSocket by LabVIEW makes the construction of a Web server easier than other languages and is compatible with other application programs. An optical current sensor was composed using a 1310 [nm] laser diode, and 9/125 [${\mu}m$] standard single mode optical fiber and was created to be a close type sensor. Data measurement using Web servers has the advantage of monitoring electric power systems at a great distance and can fuse IT technology and electric power systems. Also, this measurement uses inexpensive mounting and programming when compared to existing measurement equipment allowing the construction of a measurement system in any situation or surrounding.

Reliability Analysis of Measurement System by Observability Identification technique (기관측성 판정기법에 의한 측정시스템의 신뢰도분석)

  • Lee, Eung-Hyuk;Hong, Kwak-No;Hyun, Moon-Young
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.125-128
    • /
    • 1987
  • This paper deals with the topological observability analysis and the derivation of a reliability evaluation formula of a measurement system for state estimation. An analogy of the DC power flow method to the DC circuit analysis is introduced, and all the relationship between power flows and phase angles are replaced by the corresponding current-voltage relation. As a result, a set of topological measurement equation expressed in the form of the incidence matrix is derived for the topological analysis, and the observability test is carried out by examining the rank of the measurement matrix. The reliability evaluation formula was derived experimentally by testing the observability of sample systems of IEEE-14, IEEE-3.0, IEEE-57.

  • PDF

DEVELOPMENT OF AN IMPROVED INSTALLATION PROCEDURE AND SCHEDULE OF RVI MODULARIZATION FOR APR1400

  • Ko, Do-Young
    • Nuclear Engineering and Technology
    • /
    • v.43 no.1
    • /
    • pp.89-98
    • /
    • 2011
  • The construction technology for reactor vessel internals (RVI) modularization is one of the most important factors to be considered in reducing the construction period of nuclear power plants. For RVI modularization, gaps between the reactor vessel (RV) core-stabilizing lug and the core support barrel (CSB) snubber lug must be measured using a remote method from outside the RV. In order to measure RVI gaps remotely at nuclear power plant construction sites, certain core technologies must be developed and verified. These include a remote measurement system to measure the gaps between the RV core-stabilizing lug and the CSB snubber lug, an RVI mockup to perform the gap measurement tests, and a new procedure and schedule for RVI installation. A remote measurement system was developed previously, and a gap measurement test was completed successfully using the RVI mockup. We also developed a new procedure and schedule for RVI installation. This paper presents the new and improved installation procedure and schedule for RVI modularization. These are expected to become core technologies that will allow us to shorten the construction period by a minimum of two months compared to the existing installation procedure and schedule.

Reliability Analysis Method for Repeated UT Measurement Data in Nuclear Power Plants (원전 배관의 반복 측정 데이터에 대한 신뢰도 분석 방법)

  • Yun, Hun;Hwang, Kyeong-Mo
    • Corrosion Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.142-148
    • /
    • 2013
  • Safety is a major concern in Nuclear Power Plants (NPPs). Piping systems in NPPs are very complex and composed of many components such as tees, elbows, expanders and straight pipes. The high pressure and high temperature water flows inside piping components. As high speed water flows inside piping, the pipe wall thinning occurs in various reasons such as FAC (Flow Accelerated Corrosion), LDIE (Liquid Droplet Impingement Erosion) and Flashing. To inspect the wall thinning phenomenon and protect the piping from damages, piping components are checked by UT measurement in every overhaul. During every overhaul, approximately 200~300 components (40,000~60,000 UT data) are examined in NPPs. There are some methods from EPRI for evaluating wear rate of components. However, only few studies have been conducted to find out the raw data reliability for the wear rate evaluation. Securing the reliable raw data is the key factor for a reasonable evaluation. This paper suggests the reliability analysis method for the repeatedly measured data for wear rate evaluation.