• Title/Summary/Keyword: Power Disturbance

Search Result 717, Processing Time 0.025 seconds

Position Control of Motion Stage using Disturbance Observer (외란관측기를 이용한 모션 스테이지의 위치제어)

  • Park, Hae-Chun;Choi, Myung-Soo;Byun, Jung-Hwan
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.82-88
    • /
    • 2013
  • For commercialized servo drives of the motion stage to include embedded controller, external terminal is provided for tracking command and encoder output, but internal terminal is not for control input. Thus, it is difficult to combine out signal of embedded controller with that of external compensator such as disturbance observer. In this study, for precise tracking control of motion stage without hardware change of the servo drive, tacking control system is composed of an inner loop of servo drive and an outer loop of disturbance observer. Then, the control system is designed so that the output response of actual plant corresponds with nominal model's in transient state as well as in steady state. Finally, the experiment results show that the designed control system is effective to reconcile actual plant behavior with nominal model under nonlinear friction and parameter perturbation.

A Study on a Two-Degree-of-Freedom Servosystem Incorporating an Observer (관측기를 갖는 2자유도 서보계의 구성에 관한 고찰)

  • Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.3 no.1
    • /
    • pp.50-54
    • /
    • 1999
  • In order to reject the steady-state tracking error, it is common to introduce integral compensators in servosystems for constant reference signals. However, if the mathematical model of the plant is exact and no disturbance input exists, the integral compensation is not necessary. From this point of view, a two-degree-of-freedom(2DOF) servosystem has been proposed, in which integral compensation is effective only when there is modeling error for disturbance input. The present paper considers the design problem of 2DOF servosystem incorporating an observer. It is shown that if a state feedback gain and a observer gain satisfy a condition, the integral effect does not appear when modeling error or disturbance input exists. This result means that the servosystem does not behave as a 2DOF servosystem.

  • PDF

Position Control of Magnetic Levitation Transfer System by Pitch Angle

  • Liu Ming-Zhao;Tsuji Teruo;Hanamoto Tsuyoshi
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.264-270
    • /
    • 2006
  • Magnetic levitation transfer systems are useful for transfer tools in clean rooms and positioning control systems with high precision because of frictionless characteristics. In this paper, the new method is proposed which is a sensorless position. At first, the magnetic levitation is performed by state feedback control with a disturbance observer for each of six axes of the movement of a levitated vehicle. The position of the vehicle is then estimated as the disturbance term of a disturbance observer for a pitch angle which is one of the control axes for the magnetic levitation. In addition, the positioning force is generated by the pitch angle control which gives a tilt to the levitated vehicle so that it generates the horizontal component of force.

Disturbance Observer-based Current Measurement Offset Error Compensation in Vector-controlled SPMSM Drives (표면 부착형 동기 전동기 벡터 제어에서의 외란 관측기 기반 전류 측정 오프셋 오차 보상 방법)

  • Lee, Sang-Min;Lee, Kibok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.402-409
    • /
    • 2022
  • In vector-controlled drive systems, the current measurement offset error causes unwanted torque ripple, resulting in speed and torque control performance degradation. The current measurement offset error is caused by various factors, including thermal drift. This study proposes a simple DC offset error compensation method for a surface permanent magnet motor based on a disturbance observer. The disturbance observer is designed in the stationary reference frame. The proposed method uses only the measured current and machine parameters without additional hardware. The effect of parameter variations is analyzed, and the performance of the current measurement offset error compensation method is validated using simulation and experimental results.

Repetitive Control for rejecting periodical disturbance of PMSM (영구자석형 동기전동기의 주기적인 외란 제거를 위한 반복제어기 제어)

  • Choi, Dong-Min;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.195-196
    • /
    • 2017
  • This paper proposes a permanent magnet synchronous motor(PMSM) control using a repetitive controller. Repetitive controllers are often used to eliminate periodic disturbances. Based on this, it is possible to alleviate the torque disturbance occurring at a constant cycle to the load of the motor. This paper proposes a method of rejecting periodically generated disturbances by using a repetitive controller and verified by simulation.

  • PDF

Design of Disturbance Cancellation for Motor Driving (전동기 운전을 위한 외란상쇄 관측기 설계)

  • Kim Yong-ju;Seo Young-soo
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.150-153
    • /
    • 2002
  • This paper designed a robust control of an induction motor using a disturbance cancellation observer of a feedforward control. The speed response of conventional Pl controller characteristic is affected by variations of load torque disturbance. In the proposed system the speed control characteristic using a feedforward control isn't affected by a load torque disturbance.

  • PDF

Driving Constant Speed of Induction Motor using Disturbance Cancellation Observer (외란상쇄 관측기를 적용한 유도전동기 정속도 운전)

  • Kim Yong-ju;Seo Young-soo
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.179-182
    • /
    • 2002
  • This Paper described a robust control of an induction motor using a disturbance cancellation observer of a feedforward control, The speed response of conventional Pl controller characteristic is affected by variations of load torque disturbance. Tn the proposed system, the speed control characteristic using a feedforward control isn't affected by a load torque disturbance.

  • PDF

Design of Active Disturbance Rejection Control for Inductive Power Transfer Systems

  • Wang, Yanan;Dong, Lei;Liao, Xiaozhong;Ju, Xinglong;Xiao, Furong
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1434-1447
    • /
    • 2018
  • The control design of inductive power transfer (IPT) systems has attracted a lot of attention in the field of wireless power transmission. Due to the high-order resonant networks and multiple loads in IPT systems, a simplified model of an IPT system is preferred for analysis and control design, and a controller with strong robustness is required. Hence, an active disturbance rejection control (ADRC) for IPT systems is proposed in this paper. To realize the employment of ADRC, firstly a small-signal model of an LC series-compensative IPT system is derived based on generalized state-space averaging (GSSA), then the ADRC is implemented in the designed IPT system. The ADRC not only provides superior robustness to unknown internal and external disturbances, but also requires few knowledge of the IPT system. Due to the convenient realization of ADRC, the designed IPT system retains its simple structure without any additional circuits. Finally, a frequency domain analysis and experimental results have validated the effectiveness of the employed ADRC, especially its robustness in the presence of frequency drifts and other common disturbances.

Detection Performance and THD Analysis of Active Frequency Drift for Anti-Islanding (단독운전 방지를 위한 능동적 주파수 변환 기법의 검출 성능 및 THD 분석)

  • Jo, Yeong-Min;Choi, Ju-Yeop;Song, Seung-Ho;Choy, Ick;Lee, Young-Kwoun
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.11-19
    • /
    • 2015
  • Islanding is a phenomenon that EPS(Electric Power System) is continuously energized by PV PCS(Photovoltaic Power Conditioning System) even when EPS is isolated from the grid. Unintentional islanding will result in safety hazard, power quality degradation and many other issues. So, islanding protection of grid-connected PV PCS is a key function for standards compliance. Nowadays, many anti-islanding schemes are researched. But existing anti-islanding schemes used in PV PCS have power quality degradation and non-detection zone issues. This paper analyses not only detection performance of existed anti-islanding schemes using active frequency drift but also THD of PCS output current according to each value disturbance for anti-islanding. In addition, the lowest value of disturbance in each scheme was tabulated under guarantee of anti-islanding condition.

Active Mechanical Vibration Control of Rotary Compressors for Air-conditioning Systems

  • Park, Cheon-Su;Kim, SeHwan;Park, Gwi-Geun;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.1003-1010
    • /
    • 2012
  • Recent power electronics and variable-frequency motor drive technologies have been applied to air conditioners to improve efficiency and power density. However, the mechanical vibrations and acoustic noise resulting from the compressor still remain as a serious problem. This paper presents the development and implementation of an online disturbance state-filter for the suppression of multiple unknown and time-varying vibrations of air conditioning systems. The proposed design has a form of the state-filter based on a Luenburger-style closed-loop speed observer. An active vibration decoupling strategy with an estimated disturbance is provided, which manipulates a motor torque command. Since the proposed estimation does not require any additional transducers or hardware for obtaining real-time information upon disturbances, it is suitable for retrofitting industrial air conditioners.