• Title/Summary/Keyword: Power Amplitude

Search Result 1,055, Processing Time 0.025 seconds

STRAIN RATE CHANGE FROM 0.04 TO 0.004%/S IN AN ENVIRONMENTAL FATIGUE TEST OF CF8M CAST STAINLESS STEEL

  • Jeong, Ill-Seok;Kim, Wan-Jae;Kim, Tae-Ryong;Jeon, Hyun-Ik
    • Nuclear Engineering and Technology
    • /
    • v.43 no.1
    • /
    • pp.83-88
    • /
    • 2011
  • To define the effect of strain rate variation from 0.04% to 0.004%/s on environmental fatigue of CF8M cast stainless steel, which is used as a primary piping material in nuclear power plants, low-cycle fatigue tests were conducted at operating pressure and temperature condition of a pressurized water reactor, 15 MPa and $315^{\circ}C$, respectively. A high-pressure and high-temperature autoclave and cylindrical solid fatigue specimens were used for the strain-controlled low-cycle environmental fatigue tests. It was observed that the fatigue life of CF8M stainless steel is shortened as the strain rate decreases. Due to the effect of test temperature, the fatigue data of NUREG-6909 appears a slightly shorter than that obtained by KEPRI at the same stress amplitude of $1{\times}10^3$ MPa. The environmental fatigue correction factor $F_{en}$'s calculated with inputs of the test data increases with high strain amplitude, while the $F_{en}$'s of NUREG-6909 remain constant regardless of strain amplitude.

Evaluation of Cavitation Characteristics of 5083-O Al Alloy with Amplitude (5083-O 알루미늄 합금의 진폭에 따른 캐비테이션 침식 특성 평가)

  • Lee, Seung Jun;Kim, Seong Jong
    • Corrosion Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.205-212
    • /
    • 2012
  • With recent advances in engineering and technology, a damage on industrial machineries performing high-speed and high-power requirements has become a problem. There is an increasing possibility of cavitation damage, especially in pumps, propellers and high-speed vessels in a flowing liquid accordingly. There are several factors affecting cavitation damage on materials, including viscosity, pressure, temperature, amplitude applied. In this study, effects of cavity pressure in seawater on the damage for 5083-O aluminium alloy were evaluated by modulating amplitude. Trend of the damage with respect to time and amplitude was analyzed comparatively, and surface degradation of specimens was investigated by using Scanning Electron Microscope(SEM) and 3D microscope. The result reveals that the amount of the damage increased consistently with the increase in time and amplitude while the plastic deformation zone where no appreciable damage occurred was in less than 30 minutes.

A implementation of predistorter using the Series Diode Linearizer for RF Amplifiers (RF전력증폭기에 직렬다이오드선형화기를 이용한 전치보상기 구현)

  • Won, Yong-Kyu;Yun, Man-Soo;Lee, Sang-Cheol;Chung, Chan-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.1
    • /
    • pp.28-34
    • /
    • 2003
  • In this paper, a predistortion linearizer using series diode is proposed for linearizing the power amplifier in microwave radio systems. The power amplifier should be operated near saturation region to achieve high efficiency. But at this region, amplitude and phase distortions of the amplifier remarkably increase with the increase of input power and cause a significant adjacent channel interference. The linearizer is composed of a series diode with a parallel capacitor, which provides positive amplitude and negative phase deviations with the increasing input power. This type of linearizer using the nonlinearity of diode has improved the C/I(Carrier to Intermodulation Distortion) ratio well. By applying this linearizer to two-tone 880MHz power amplifier, adjacent channel leakage power is improved up to 5dBm.

Real and Reactive Power Control of Battery Energy Storage System (전지전력저장시스템의 유효 및 무효전력제어)

  • Kim, Dae-Won;Choi, Joon-Ho;Jung, Sung-Kyo;Kim, Jae-Chul;Choi, Byoung-Su
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1189-1191
    • /
    • 1999
  • This paper deals with the real and reactive power control of BESS(Battery Energy H Storage System) interconnected to power system. The real and reactive power control of proposed customer side BESS are performed by controlling the amplitude and the phase of inverter output voltage via power flow equation. Also in order to control the amplitude and phase of output voltage of proposed BESS, single-pulse width control method is used. The BESS and controller is implemented and the active and reactive power control is simulated by using the PSCAD/EMTDC simulation program.

  • PDF

A Study on the Ultrasonic Measurement for Damage Evaluation of Power Plant Bearing (발전용 베어링 손상평가를 위한 초음파 측정 연구)

  • Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1727-1732
    • /
    • 2004
  • For the purpose of monitoring by ultrasonic test of the ball bearing conditions in rotating machinery, a system for their diagnosis was developed. ultrasonic technique is used to detect abnormal conditions in the bearing system. And various data such as frequency spectrum, energy and amplitude of ultrasonic signals, and ultrasonic parameters were acquired during experiments with the simulated ball bearing system. Based on the above results and practical application for power plant, algorithms and judgement criteria for diagnosis system was established.

  • PDF

Digital Control of Single Phase Buck-Boost Converter by Pulse Amplitude Modulation Mehtod (PAM방식을 적용한 단상 승강압형 정류기의 디지탈제어)

  • 김태진;변영복;조기연;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.54-57
    • /
    • 1998
  • This paper describes a digital implementation of a pulse amplitude modulation(PAM) method for a unity-power-factor buck-booster converter. A digital controller is designed and implemented by a Digital Signal Processor(DSP) to replace the analog control circuit for PAM. Experimental results are presented and compared with simulations.

  • PDF

Analysis and Design of the Interface Inductor and the DC Side Capacitor in a STATCOM with Phase and Amplitude Control Considering the Stability of the System

  • Zhao, Guopeng;Han, Minxiao;Liu, Jinjun
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.193-200
    • /
    • 2012
  • Previous publications regarding the design and specifications of the interface inductor and the DC side capacitor for a STATCOM usually deal with the interface inductor and the DC side capacitor only. They seldom pay attention to the influences of the interface inductor and capacitor on the performance of a STATCOM system. In this paper a detailed analysis of influence of the interface inductor and the DC side capacitor on a STATCOM system and the corresponding design considerations is presented. Phase and amplitude control is considered as the control strategy for the STATCOM. First, a model of a STATCOM system is carried out. Second, through frequency domain methods, such as transfer functions and Bode plots, the influence of the interface inductor and the DC side capacitor on the stability and filtering characteristics of the STATCOM are extensively investigated. Third, according to this analysis, the design considerations based on the phase margin for the interface inductor and the DC side capacitor are discussed, which leads to parameters that are different from those of the traditional design.

The effects of geometrical buoy shape with nonlinear Froude-Krylov force on a heaving buoy point absorber

  • Kim, Sung-Jae;Koo, Weoncheol;Kim, Moo-Hyun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.86-101
    • /
    • 2021
  • This study examined the effects of buoy shape and Nonlinear Froude-Krylov force (NFK) on a heaving-buoy-type Wave Energy Converter (WEC). Based on the Maclaurin expansion, the theoretical solutions of the NFK were derived for three different buoy shapes; hemispheric buoy, circular vertical cylinder, and truncated conical cylinder. A hydraulic power take-off system was adopted, and the latching control strategy was applied to maximize the extracted power from the WEC. The nonlinear effects of the Froude-Krylov force and restoring force on the heaving point absorber were investigated by comparing the heave Response Amplitude Operator (RAO) and time-averaged power extraction. The results showed that the conventional linear analyses were overestimated by up to 50% under the high amplitude wave condition. The latching control strategy was the most effective when peak wave period of regular or irregular wave was 0.4-0.45 times the heave natural period of the buoy.

Study on the Real-Time Leak Monitoring Technique for Power Plant Valves (발전용 밸브누설 실시간 감시기술 연구)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

A Compensator for Lateral Current Reduction Applied to Autonomously Controlled UPSs Connected in Parallel

  • Sato Kazuhide Kazuhide;Kawamura Atsuo
    • Journal of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.312-318
    • /
    • 2005
  • This paper presents a compensator for reduction of the reactive lateral current in multiple autonomously controlled uninterruptible power supplies (UPS) connected in parallel. This compensator acts directly on the control equation for voltage amplitude and it provides an improved current distribution especially in the case of parallel connection of UPSs with different output power ratings. Observations show that the original control equation for output voltage amplitude is efficient for voltage regulation but it causes great variation of voltage levels. A compensator with the same structure is added to counterbalance the variation caused by the original control equation. Simulations show promising results with the employment of the proposed compensator. Our simulations are confirmed by experimental results using three UPSs with different output ratings and voltage limiters ($1\%$) connected in parallel under various conditions.