• Title/Summary/Keyword: Potential Pole

Search Result 71, Processing Time 0.02 seconds

The Comparison and Analysis about Earth Resistance for Measuring of Earth Resistance by Measurement Positions of Auxiliary Poles (접지저항 측정을 위한 보조전극 위치에 따른 접지저항 비교 분석)

  • Han, Woon-Ki;Jung, Jin-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.128-133
    • /
    • 2009
  • This paper describes the comparison and analysis about measurement method of earthing resistance by positions of potential pole and current pole. In KOREA, a diagonal by 6.5 times of earthing electrode for measurement of earthing resistances but this method was almost impossible in the downtown area. For solving this problem, in this paper measuring of earthing resistance changing parameters. The parameter was a distances of earthing electrode, potential pole & current pole and the another parameter was an angles of potential pole & current pole. Analysis result, earthing resistance stability that conditions. Fist, distance from earthing electrode to current pole was over 50[m] and distance from earthing electrode to potential pole was over 30[m]. Second, angles of potential pole & current pole was over $45[^{\circ}]$.

Analyses of Earth Surface Potentials Depending on Soil Structures (대지구조에 따른 대지표면전위의 분석)

  • Lee, Bok-Hee;Baek, Young-Hwan;Jung, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1796-1801
    • /
    • 2007
  • This paper presents electric potential rise on the surface of the earth due to ground currents. It is the aim of this paper to propose fundamental data relevant to the earth surface potentials depending on the soil structures. The earth potential rise, touch and step voltages in the immediate vicinity of the ground rod of a distribution pole were measured and analyzed. The results described in this paper are based on laboratory measurements which were intended to simulate conditions existing in actual installations. As a result, the earth surface potential rise, touch and step voltages strongly depend on the soil structure. The highest earth surface potential occurred in the vicinity of the top of ground rod. When the ground rod was installed in the distance range of $1{\sim}1.5\;m$ from distribution pole, the highest touch voltages appeared near the place of 1 m on the straight line connecting the distribution pole to ground rod.

Pole-pole array electrical resistivity survey and an effective interpretational scheme of its data (2극법 전기비저항 탐사 자료의 효율적인 해석방법)

  • Cho Dong-Heng;Lee Chang Yourl;Jee Sang-Keun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.112-131
    • /
    • 2000
  • In spite of its many strong points, pole-pole electrode configuration is not often used for ground electrical resistivity survey except for bore hole survey as normal logging and for archaeological investigation. Above all, poor spatial resolution of pole-pole survey may be responsible for this. But recent experiences so far gained by the present authers lead them to think that pole-pole survey can be at least a viable means of reconnaissance survey in near-surface conductive environment and an effective interpretational scheme may augment its resolution. As well known, a response of any other electrode configuration is a linear combination of pole-pole responses. Based on this principle of linear superposition and the principle of reciprocity, the other 'responses' can be derived with simple additions and subtractions of pole-pole responses. Though such responses are not always correct due to the adverse effects of noises, combined with the potential decay curves, they can be helpful to interprete better pole-pole survey data especially in connection of the resolution. This can be comparable to the use of the first or second derivatives of gravity and magnetic intensity surveys.

  • PDF

Broadband Piezoelectric Vibration Energy Harvester Using Pole-Zero Cancellation Technique (극점-영점 상쇄 기법을 이용한 광대역 압전 진동 에너지 하베스터)

  • Kim, Gi-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.2
    • /
    • pp.87-92
    • /
    • 2014
  • This paper presents a new design for a piezoelectric energy harvester with the potential to harvest vibration energy over a wide range of excitation frequencies, particularly beyond the resonance frequency. The piezoelectric vibration energy harvester employs the concept of pole-zero cancellation occurring in a lever type anti-resonant system. The experimental results show that the proposed energy harvester can provide the potential possibility of a broadband piezoelectric vibration energy harvester.

The Deterioration Diagnosis of pole Transformer using Remote Measurement (주상변압기의 열화진단을 위한 원격측정)

  • 송현선;이상돈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • This paper proposes on-line based a deterioration diagnosis pole transformers using various sensors such as thermistor, current transformer and potential transformer. We measured load current and temperature to diagnose pole transformer using R/F( radio frequency ) wireless data communication module. We represent the graphs of their feature. The result of this paper shows that the proposed device car be used as deterioration diagnosis device of pole transformers.

A problem in the cross-hole resistivity method using pole-pole array (단극배열을 이용한 시추공-시추공 전기비저항 탐사법의 문제점)

  • Jo, In Gi;Choe, Gyeong Hwa
    • Journal of the Korean Geophysical Society
    • /
    • v.1 no.1
    • /
    • pp.51-58
    • /
    • 1998
  • A numerical program has been developed to model 2-D resistivity responses for a pole-pole array configuration in cross-hole resistivity measurements. Apparent resistivity and secondary potential were computed using the program for a cylindrical inhomogeneity in an uniform host medium excited by a point source of current in a borehole. Surprisingly apparent resistivity in the receiver hole turns out to be lower than the one of surrounding medium regardless of the conductivity of cylindrical inhomogeneity. Using only cross-hole data, therefore, it is impossible to interpret the conductivity of inhomogeneity. To overcome this problem, 3-D measurement and interpretation are necessary. If 3-D data acquisition is impossible, inline data should be used to get the information about the conductivity of inhomogeneity.

  • PDF

A Study on the Potential Characteristics of Human-body Contacted the Charging Part (충전부에 접촉된 인체의 전위특성에 관한 연구)

  • Shong, Kil-Mok;Choi, Chung-Seog;Jung, Yeon-Ha;Roh, Young-Su;Kwak, Hee-Ro;Park, Jung-Shin
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1942-1944
    • /
    • 2004
  • In this paper, we studied on the potential characteristics of human-body contacted the charging part. A charging part of electrical facilities and the earth are simulated by the e1ectrode pole and conductive rubber plates respectively. As the results of these follows, when the potential distribution of the human-body contacted the charging part is far from the electrode pole, a lot of currents flow through the human-body. Besides human-body non-contacted the charging part is affected by step voltage. Therefore, we could find out the causes of the electric shock accidents and be expected to the data for minimization of human error occurred the workspace.

  • PDF

A Study on the Modified Electrode Arrays in Two-Dimensional Resistivity Survey (2차원 전기비저항 탐사를 위한 변형된 전극배열법에 관한 연구)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.3
    • /
    • pp.59-69
    • /
    • 2001
  • Five kinds of modified electrode arrays were proposed to overcome the weak points of the commonly used arrays using dipole and/or pole in two-dimensional resistivity surveys. The modified pole-pole array was suggested to overcome the inefficiency caused by distant earthing in pole-pole array. Four kinds of modified arrays using dipole were designed to enhance the signal-to-noise ratio of the conventional dipole-dipole and pole-dipole arrays through boosting up the measured potential difference. In the numerical experiments using the two-dimensional modeling and inversion, the effects of the ambient electrical noise and the resolving power were examined and the results showed the validity of the modified arrays proposed in this study.

  • PDF

Reduction and Analysis for Cogging Torque of Permanent Magnet Synchronous Generators with Multi-Pole Rotor for Wind Power Application (풍력발전용 영구자석 다극 동기발전기의 코깅토크의 해석 및 저감)

  • Jang, Seok-Myeong;Lee, Sung-Ho;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.375-383
    • /
    • 2008
  • This paper deals with reduction and analysis of cogging torque for permanent magnet synchronous generators with multi-pole rotor for wind power applications. Open-circuit field solutions are derived using a magnetic vector potential and a two-dimensional (2-d) polar coordinate systems. On the basis of derived open-circuit field solutions and 2-d permeance functions, we also derive open-circuit field solutions considering stator slotting effects. By using open-circuit field solutions considering stator slotting effects and energy variation methods, this paper analytically predicts the cogging torque considering skew effects. All analytical results are shown in good agreement with those obtained from finite element (FE) analyses. In order to reduce the cogging torque, by predicting the variation of the cogging torque according to pole arc/pitch ratio using analytical and FE methods, pole arc/pitch ratio which makes the cogging torque minimum are determined. However, we confirm that measured value for cogging torque of the PMG with determined pole arc/pitch ratio is twice higher than predicted value. Therefore, the reason for an error between measured and predicted cogging torque is discussed in terms of a shape of PMs and is proved experimentally.

The Crosshole Resistivity Method Using the Mixed Array (혼합배열을 사용하는 시추공간 전기비저항 탐사)

  • Cho In-Ky;Han Sung-Hoon;Kim Ki-Ju
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.250-256
    • /
    • 2002
  • Resistivity tomography has become an important tool to image underground resistivity distribution. This method has been widely applied to site investigation for engineering and environmental purpose. In resistivity tomography, various electrode arrays can be used and each array has both merits and demerits. For example, the pole-pole array has high signal to noise ratio (S/N ratio), but its resolution is too low. The dipole-dipole array has low S/N ratio, but its resolution is very high. The Pole-dipole may has intermediate Snf ratio and resolution. The modified Pole-dipole array, recently proposed, shows reasonable S/N ratio and resolution, which are comparable to the pole-dipole array. These electrode arrays except the pole-pole array, however, have the problem that the apparent resistivity can diverge at some special electrode Positions. Also, the Pole-Pole array may not reflect the doe resistivity of an anomalous body. In this study, we propose a new electrode array, mixed array, where pole-dipole and modified pole-dipole ways are selectively used with the relative positions of current and potential electrodes. The mixed array has the same level of S/N ratio and resolution as the pole-dipole array and the apparent resistivity does not diverge in the receiver hole. Furthermore, the apparent resistivity using the array can reflect the true resistivity of the anomalous body.