• 제목/요약/키워드: Potable-water system

검색결과 37건 처리시간 0.024초

Condenser cooling system & effluent disposal system for steam-electric power plants: Improved techniques

  • Sankar, D.;Balachandar, M.;Anbuvanan, T.;Rajagopal, S.;Thankarathi, T.;Deepa, N.
    • Membrane and Water Treatment
    • /
    • 제8권4호
    • /
    • pp.355-367
    • /
    • 2017
  • In India, the current operation of condenser cooling system & effluent disposal system in existing power plants aims to reduce drawal of seawater and to achieve Zero Liquid Discharge to meet the demands of statutory requirements, water scarcity and ecological system. Particularly in the Steam-Electric power plants, condenser cooling system adopts Once through cooling (OTC) system which requires more drawal of seawater and effluent disposal system adopts sea outfall system which discharges hot water into sea. This paper presents an overview of closed-loop technology for condenser cooling system and to achieve Zero Liquid Discharge plant in Steam-Electric power plants making it lesser drawal of seawater and complete elimination of hot water discharges into sea. The closed-loop technology for condenser cooling system reduces the drawal of seawater by 92% and Zero Liquid Discharge plant eliminates the hot water discharges into sea by 100%. Further, the proposed modification generates revenue out of selling potable water and ZLD free flowing solids at INR 81,97,20,000 per annum (considering INR 60/Cu.m, 330 days/year and 90% availability) and INR 23,760 per annum (considering INR 100/Ton, 330 days/year and 90% availability) respectively. This proposed modification costs INR 870,00,00,000 with payback period of less than 11 years. The conventional technology can be replaced with this proposed technique in the existing and upcoming power plants.

대구시 인근에 산재한 약수에 대한 위생학적 조사(1986) (A Sanitary Survey on the Medicinal Water Springs Located near Taegu City(1986))

  • 차상덕;장봉기;천병열;김두희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제19권2호
    • /
    • pp.273-280
    • /
    • 1986
  • 최근 질병의 치료 및 건강증진을 목적으로 많은 사람들이 약수를 마시고 있어서 이에대한 위생학적검사가 중요한 관심이 되고있다. 대구직할시와 인근한 11개 약수터를 대상으로 1986년 3월 27일부터 4월 17일까지 약수터의 위생시설상태을 알아보고 약수를 채취하여 생물학적 및 이화학적 검사를 실시하였다. 주변위생시설이 제대로 된 곳은 11개 약수터 중 3개소로 27.3%에 불과하였으며 생물학적검사 중 대장균이 음성인 곳은 1군데 뿐이었다. 이화학적 성분검사결과 음료수 수질기준을 초과하지 않은 지역은 3개소 이었으며 특히 '가창약수' '영천약수' '달기약수'는 중금속 농도가 음료수 허용기준치를 초과하고 심한 산성이었다. 이상의 결과로 볼 때 세균 및 이화학적 성분 조사에서 전체 11개 대상 약수에서 우리나라 음료수 수질기준에 비추어 볼 때 부적합한 결과로 나타났으며 가장 부적합한 항목이 많은 곳은 가창 황물과 영천 황수였다. 이에 대한 대책으로서 약수터 주위의 위생시설의 미비점 보완 및 약수터의 위생적인 관리가 필요하며 중금속 농도가 높은곳은 오염원을 찾아 제거시켜야할 것이다.

  • PDF

실리카겔을 이용한 흡착식 담수화 시스템의 기초연구 (Development of Adsorption Desalination System Utilizing Silica-gel)

  • 현준호;김영민;정진호;이윤준;천원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.204-209
    • /
    • 2011
  • According to the environment report of UN, korea was classified as potable water shortage countries. Approximately 71% of the Earth's surface is covered by ocean. However, it is difficult to use for industry of residential purpose without a certain processing. The development of solar and waste-heat used absorption desalination technology have been examined as a viable option for supplying clean energy. In this study, the modelling of the main devices for solar and waste-heat used and adsorption desalination system was introduced. The design is divided into three parts. First, the evaporator for the vaporization of the top water is designed, and then the reactor for the adsorption and release of the steam is designed, followed by the condenser for the condensation of the fresh water is designed. In addition, new features based on the energy balance are also included to design absorption desalination system. In this basicresearch, One-bed(reactor) adsorption desalination plant that employ a low-temperature solar and waste energy was proposed and experimentally studied. The specific water yield is measured experimentally with respect to the time controlling parameters such as heat source temperatures, coolant temperatures, system switching and half-cycle operational times.

  • PDF

Influence of mixed liquor suspended solids on the removal efficiency of a hybrid membrane bioreactor

  • Palmarin, Matthew J.;Young, Stephanie
    • Membrane and Water Treatment
    • /
    • 제7권1호
    • /
    • pp.11-22
    • /
    • 2016
  • The characterization of treatment performance with respect to mixed liquor suspended solids (MLSS) concentration enables greater control over system performance and contaminant removal efficiency. Hybrid membrane bioreactors (HMBRs) have yet to be well characterized in this regard, particularly in the context of greywater treatment. The aim of this study, therefore, was to determine the optimal MLSS concentration for a decentralized HMBR greywater reclamation system under typical loading conditions. Treatment performance was measured at MLSS concentrations ranging from 1000 to 4000 mg/L. The treated effluent was characterized in terms of biochemical oxygen demand ($BOD_5$), chemical oxygen demand (COD), turbidity, ammonia ($NH_3$), total phosphorus (TP), total kjeldahl nitrogen (TKN), and total nitrogen (TN). An MLSS concentration ranging from 3000 to 4000 mg/L yielded optimal results, with $BOD_5$, COD, turbidity, $NH_3$, TP, TKN, and TN removals reaching 99.2%, 97.8%, 99.8%, 99.9%, 97.9%, 95.1%, and 44.8%, respectively. The corresponding food-to-microorganism ratio during these trials was approximately 0.23 to 0.28. Operation at an MLSS concentration of 1000 mg/L resulted in an irrecoverable loss of floc, and contaminant residuals exceeded typical guideline values for reuse in non-potable water applications. Therefore, it is suggested that operation at or below this threshold be avoided.

Using Artificial Neural Networks for Forecasting Algae Counts in a Surface Water System

  • Coppola, Emery A. Jr.;Jacinto, Adorable B.;Atherholt, Tom;Poulton, Mary;Pasquarello, Linda;Szidarvoszky, Ferenc;Lohbauer, Scott
    • 생태와환경
    • /
    • 제46권1호
    • /
    • pp.1-9
    • /
    • 2013
  • Algal blooms in potable water supplies are becoming an increasingly prevalent and serious water quality problem around the world. In addition to precipitating taste and odor problems, blooms damage the environment, and some classes like cyanobacteria (blue-green algae) release toxins that can threaten human health, even causing death. There is a recognized need in the water industry for models that can accurately forecast in real-time algal bloom events for planning and mitigation purposes. In this study, using data for an interconnected system of rivers and reservoirs operated by a New Jersey water utility, various ANN models, including both discrete prediction and classification models, were developed and tested for forecasting counts of three different algal classes for one-week and two-weeks ahead periods. Predictor model inputs included physical, meteorological, chemical, and biological variables, and two different temporal schemes for processing inputs relative to the prediction event were used. Despite relatively limited historical data, the discrete prediction ANN models generally performed well during validation, achieving relatively high correlation coefficients, and often predicting the formation and dissipation of high algae count periods. The ANN classification models also performed well, with average classification percentages averaging 94 percent accuracy. Despite relatively limited data events, this study demonstrates that with adequate data collection, both in terms of the number of historical events and availability of important predictor variables, ANNs can provide accurate real-time forecasts of algal population counts, as well as foster increased understanding of important cause and effect relationships, which can be used to both improve monitoring programs and forecasting efforts.

Performances of submerged membrane photocatalysis reactor during treatment of humic substances

  • Halim, Ronald;Utama, Robert;Cox, Shane;Le-Clech, Pierre
    • Membrane and Water Treatment
    • /
    • 제1권4호
    • /
    • pp.283-296
    • /
    • 2010
  • During the disinfection of potable water, humic substances present in the solution react with chlorine to form potential carcinogenic compounds. This study evaluates the feasibility of using a submerged membrane photocatalysis reactor (SMPR) process for treatment of humic substances through the characterization of both organic removal efficiency and membrane hydraulic performance. A simple SMPR was operated and led to the removal of up to 83% of the polluting humic matters. Temporal rates of organic removal and membrane fouling were found to decrease with filtration time. Using tighter membrane in the hybrid process resulted in not only higher organic removal, but also more significant membrane fouling. Under the experimental conditions tested, optimum $TiO_2$ concentration for humic removal was found to be 0.6 g/L, and increasing initial pollutant concentration expectedly resulted in a more substantial membrane fouling. The importance of the influent nature and pollutant characteristics in this type of treatment was also assessed as various water sources were tested (model humic acid solution vs. local water containing natural organic matters). Results from this study revealed the promising nature of the SMPR process as an alternative technique for organic removal in the existing water treatment system.

Autopsy of Nanofiltration membrane of a decentralized demineralization plant

  • El-ghzizel, Soufian;Jalte, Hicham;Zeggar, Hajar;Zait, Mohamed;Belhamidi, Sakina;Tiyal, Fathallah;Hafsi, Mahmoud;Taky, Mohamed;Elmidaoui, Azzedine
    • Membrane and Water Treatment
    • /
    • 제10권4호
    • /
    • pp.277-286
    • /
    • 2019
  • In 2014, the first demineralization plant, using nanofiltration (NF) membrane coupled with renewable energies was realized at Al Annouar high school of Sidi Taibi, Kenitra, Morocco. This project has revealed difficulties related to the membrane performances loss (pressure increase, flux decline, poor water quality of the produced water and increase of energy consumption), as consequences of membrane fouling. To solve this problem, an autopsy of the membrane was done in order to determine the nature and origin of the fouling. The samples of membrane and fouling were then analyzed by scanning electron microscopy using a scanning electron microscope (SEM) connected with an energy dispersive X-ray (EDX) detection system and X-ray diffractometer (XRD). Moreover, three cleaning solutions (hydrochloric acid, nitric acid and sulfuric acid) were tested and assessed in a single cleaning step to find the suitable one for the fouled membrane to regain its initial permeability and performances. The analysis of the experimental results showed that the fouling layer is mainly composed of calcium carbonate (inorganic fouling). Results showed also that the permeability is improved by the hydrochloric acid cleaning (pH=3) with a cleaning efficiency of 93%. Cleaning efficiency did not exceed 75 % with nitric acid (pH=3) and 40 % with sulfuric acid (pH=3).

중수도개발연구(中水道開發研究) (A Study on the Water Reuse Systems)

  • 박중현;이성기;정재철
    • 대한토목학회논문집
    • /
    • 제4권4호
    • /
    • pp.113-125
    • /
    • 1984
  • 우리 나라는 수공급(水供給)을 주로 댐개발(開發)에 의존(依存)하여 왔으나 이와 같은 방식(方式)은 앞으로 댐적지(適地)의 감소(減少), 건설비(建設費)의 앙등(昻騰), 수몰지역주민(水沒地域住民)의 생활재건대책(生活再建對策), 환경영향(環境影響) 등의 제요인(諸要因)으로 인하여 계속하여 개발(開發)하기 어려운 상황(狀況)에 있다. 한편 수수요(水需要)는 도시(都市)로의 인구집중(人口集中), 생활수준(生活水準)의 향상(向上), 산업발전(産業發展) 등으로 인하여 계속 증가(增加)되고 있으며 앞으로도 인구(人口)의 증가(增加)와 경제활동(經濟活動)의 고도화(高度化)에 따른 도시기능(都市機能)의 향상(向上)에 의해 증가(增加)될 것으로 예상(豫想)된다. 따라서, 앞으로 늘어날 수수요(水需要)에 대처(對處)하기 위해서는 지하수(地下水)의 개발(開發), 해수(海水)의 담수화(淡水化), 그리고 물을 순환재이용(循環再利用)하는 중수도(中水道)의 도입(導入)이 절실(切實)하며 그 연구(硏究) 또한 시급하다. 중수도(中水道)란 종래(從來) 수도(水道)에 의해서 급수(給水)되고 있던 용도(用途)가운데 반드시 음용수(飮用水)와 같은 정도(程度)의 청정(淸淨)을 요(要)하지 않는 용도(用途)에 대(對)하여 각(各) 용도(用途)에 적합(適合)한 수질(水質)의 중수(中水)를 공급(供給)하는 것으로써 사람이 마시기에 적합(適合)하지 않은 물을 공급(供給)하는 시설(施設)의 총체(總體)라고 정의(定義)한다. 이와 같은 중수도(中水道)의 용도(用途)로는 수세식(水洗式) 변소용수(便所用水), 에어컨냉각용보급수(冷却用補給水), 세차용수(洗車用水), 살수용수(撒水用水), 가로청소용수(街路淸掃用水), 조경용보급수(造景用補給水), 소화용수(消火用水) 등을 들 수 있으며, 원수(原水)로는 건물내(建物內)에서 발생(發生)하는 잡배수(雜排水), 수세식(水洗式) 변소용수(便所用水), 냉동냉각배수(冷凍冷却排水), 하수처리수(下水處理水), 오탁하천수(汚濁河川水), 그리고 우수(雨水), 지하수(地下水) 등을 생각할 수 있다. 그러나, 원수(原水)를 선정(選定)할 때는 수질(水質)과 함께 수량(水量)이 풍부(豊富)한가에 대해서도 고려(考慮)하여야 한다. 중수도(中水道)의 형태(形態) 및 분류(分類)는 개방계(開放系) 순환방식(循環方式)과 폐쇄계(閉鎖系) 순환방식(循環方式)으로 대별(大別)되며, 이를 규모(規模)에 따라 개별순환방식(個別循環方式), 지구순환방식(地區循環方式), 광역순환방식(廣域循環方式)의 3 가지로 나눈다. 중수도처리방식(中水道處理方式)은 활성오니법(活性汚泥法), 회전원판법(回轉圓板法), 접촉폭기법(接觸曝氣法)을 포함(包含)한 생물화학적(生物化學的) 처리법(處理法)과 의집심의법(擬集沈擬法), 사려과법(砂濾慮過法), 활성탄처리법(活性炭處理法), ozone 처리법(處理法), 염소처리법(鹽素處理法), 막처리(膜處理) 등을 포함(包含)한 물리화학적(物理化學的) 처리법(處理法)으로 대별(大別)된다. 또한 현재(現在) 외국(外國)에서 실시(實施)하고 있는 중수도(中水道)의 예(例) 조사(調査)하였으며, 중수도이용(中水道利用)의 효과(效果)를 직접적(直接的) 효과(效果)와 부수적(附隨的) 효과(效果)로 나누어 기술(記述)하였다. 또한 중수도(中水道) 개발시(開發時)의 문제점(問題點)을 순환방식별(循環方式別)로 조사(調査)하였으며, 기술(技術), 위생(衛生), 관리상(管理上)의 문제(問題)와 비용문제(費用問題), 법령상(法令上)의 문제(問題)를 다루었다. 중수도(中水道)를 개발(開發)하기 위해 사업자(事業者)(설치자(設置者))와 행정기관(行政機關)의 역할(役割) 중수도(中水道)를 위한 시설(施設)의 구조기준(構造基準) 및 유지관리기준(維持管理基準), 재정적(財政的) 조치(措置) 등에 대해서 연구(硏究)하였다.

  • PDF

역삼투막 전처리로서의 2단 섬유상 여과기를 이용한 정수처리 연구 (Potable Water Treatment Study using the Double Stage Fiber Filter for the Pre-treatment of the Reverse Osmosis Membrane)

  • 배시열;장형욱;윤창한
    • 멤브레인
    • /
    • 제20권2호
    • /
    • pp.97-105
    • /
    • 2010
  • 2009년 1월 3일부터 12월 1일까지 11개월간 공업용수를 주변지역에 공급하는 A정수장 응집침전조의 상등수를 대상으로 실험을 진행한 본 연구는 RO막 전처리 장치로서의 압력식 섬유여과기인 PCF 여과기 2대를 직렬연결한 공정의 적용 가능성을 평가한 것이다. 성능평가는 SDI (Silt Density Index)를 통해 간접적으로 RO막에 대한 전처리 성능을 평가하였다. 실험 기간 동안 PCF Filter로 유입된 원수의 탁도는 평균 0.79 (0.28~4.01) NTU이었으며, 처리수의 탁도는 평균 0.16(0.04~0.50) NTU로 탁도 제거효율은 평균 77%이었다. 일일 평균 처리유량은 약 230 $m^3$/day고 평균 역세유량은 8.7 $m^3$/day로 평균 역세수량은 3.8%로 나타났다. 여과수의 탁도 및 SDI 값은 측정 전 보관시간에 따라 증가하는데 이번 실험에서 몇몇 시료는 1~11일 동안 보관한 후 탁도 및 SDI가 측정되었으며, 이들 전체의 평균 SDI 값은 3.6 (2.26~5.00)으로 RO 제조업체에서 RO의 수명보증을 위해 통상 요구하는 SDI 값인 5.0 이하를 나타내었다. 따라서 RO 전처리공정의 SDI 측면에서 2단 섬유여과 공정이 적합함을 알 수 있었다.

펌프의 효율측정 장비에 관한 연구 (Study on the Device for Pump Efficiency Measurement)

  • 배철오
    • 선박안전
    • /
    • 통권33호
    • /
    • pp.53-62
    • /
    • 2012
  • 펌프는 산업 및 건설현장에 급수, 냉난방 및 산업공정에서 다양하게 사용되고 있으며, 전체 국가 전력의 약 20%를 소비하고 있다. 하지만 에너지 낭비요소에 대한 관리는 거의 이루어지지 않고 있는 실정이다. 따라서 만일 효율이 저하된 상태로 펌프가 운전된다면 그의 에너지 낭비는 대단히 크게 된다. 펌프의 경우 초기 구입비용에 비해 사용하면서 발생하는 전력비용이 대단히 크기 때문에 이러한 낭비를 줄이기 위해서는 펌프의 효율을 정기적으로 측정하여 펌프의 운전 상태를 진단함으로써 펌프의 최적운전상태 및 교환주기 등을 제시할 수 있을 것이다. 본 연구에서는 펌프의 효율측정을 위해 열역학적 방법과 수력학적 방법(전통적인 방법)의 두 가지 방법으로 측정할 수 있는 장비에 대해서 소개하고 실제 펌프의 효율을 계산하여 그 유효성을 확인하였다.

  • PDF