• 제목/요약/키워드: Post Insulator

검색결과 46건 처리시간 0.034초

애자표면의 오손물 누적에 관한 메커니즘 연구 (A Study on Mechanism about Contaminant Accumulation of Insulator Surface)

  • 박재준
    • 정보학연구
    • /
    • 제8권2호
    • /
    • pp.85-91
    • /
    • 2005
  • We studied a pollution mechanism for simulation of contamination environment in industrial concentrated area of around a metropolitan that made to circulated flow in the chamber. In case of the virgin both side of EPDM or Silicon insulator, we confirmed that the pollution to much more than service insulator in the field. Also contamination of initial state of the virgin didn't falling in spite of physical outside factor easily. This study confirmed to that the silicon was too much accumulated pollution contrast to EPDM insulator from scatter(spray) point to regular interval position use the Kaolin contaminant in the chamber. There are effected to the hydrophobicity of polymer insulator due to the pollution. In ceramic insulator, we get to know that pollution is much more at the Post insulator with vertical than with horizontal setup insulator.

  • PDF

放射線이 照射된 MIS capacitor의 電荷 蓄積 및 flat band 전압 이동에 대한 實驗 및 數値的 硏究 (Experiments & numerical analysis of charge accumulation and flat band voltage shifts in irradiated MIS capacitor)

  • 황금주;김홍배;손상희
    • 대한전기학회논문지
    • /
    • 제44권4호
    • /
    • pp.483-489
    • /
    • 1995
  • To investigate the mechanism generated by irradiation in the insulator layer irradiated MIS (Metal - Insulator - Semiconductor) device, the various types of MIS capacitors depending on insulator thickness, insulator types and implanted impurities are fabricated on the P-type wafer. MIS capacitors exposed by 1Mrad Co$^{60}$ .gamma.-ray are measured for flat band voltage and charge density shifts pre- and post-irradiation. The measuring results of post-irradiation show the flat band voltage shifting toward negative direction and charge density increasing regardless of parameters. This results have a good agreement with calculated data by computer simulation. Si$_{3}$N$_{4}$ layers have a good radiation-hardness than SiO$_{2}$ layers compared to the results of post-irradiation. Also, radiation-induced negative trap is discovered in the implanted insulator layer. Using numerical analysis, four continuty equations (conduction-band electrons continuity equation, valence-band holes continuity equation, trapped electrons continuity equation, trapped holes continuity equation) are solved and charge distributions according to the distance and Si-Insulator interface states are investigated.

  • PDF

지지애자의 표면오염 모니터링 기술 및 장치 (Monitoring Technique and Device of Surface Contamination for Line-Post Insulator)

  • 길경석;박대원;정광석;김선재;서동환
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.413-417
    • /
    • 2010
  • Line to ground faults by deterioration of insulators has frequently occurred in power system, and the main cause is surface contamination of the insulators. The contamination of insulator is analyzed by monitoring the surface leakage current flowing them. The suspension insulator is monitored by installation of a zero-phase current sensor(ZCT), but the line-post insulator is impossible to apply the same method because of its large diameter structure. This paper proposed a detection method of surface leakage current for a line-post insulator, and it can easily be applied to new and/or built insulators. The leakage current is indirectly calculated from the potential difference between the metal electrode attached on the surface of insulator and the ground connector. To evaluate the performance of the proposed method, the leakage current is compared as a function of contamination condition controlled by the density of NaCl solution. The leakage current is proportioned to the density of NaCl solution, and the voltage detected by the electrode showed the same trend. From the experimental results, we designed and fabricated a monitoring device which is composed of a detection electrode, signal converter, microprocessor, and ZigBee, and its measurement range is $10{\mu}A{\sim}5mA$.

폴리머 LP애자의 설계해석과 전기적 성능 시험 (The Design Analysis and Electrical Performance Test of Polymer LP Insulator)

  • 이운용;조한구;박상호;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, polymer line post insulator has been designed and investigated electric field distribution by FEM. Designed LP insulators have been tested as insulator performance test, such as power frequency voltage test, lightning impulse voltage test, artificial pollution test and flexural load test.

  • PDF

인공오손에 따른 배전기자재의 건조 및 습윤 섬락에 관한 연구 (The Study on the Dry and Wet Flashover Voltages of the Artificially Salt Contaminated Distribution Facilities)

  • 김찬영;김동명;권태호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.487-488
    • /
    • 2008
  • The dry and wet flashover characteristics on the contaminated distribution facilities was investigated. The test were carried out on the suspension insulator, line post insulator, lightning arrester, cut off switch, etc. In the dry state, the flashover voltages of facilities contaminated with B, C, D classes are similar to the non-contaminated ones. However, in the wet state, the flashover voltages of facilities contaminated with B, C, D classes are decreased. The flashover voltages of some few facilities show under the standard value. This results indicate that the high humidity may cause the flashover on distribution facilities.

  • PDF

전자파 잡음을 이용한 전기설비 불량 검출장치 개발 (Development of the equipment for detecting the poor power facilities by receiving electric noises)

  • 이복규;강성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1356-1359
    • /
    • 1997
  • There are various methods to detect the faulty electric facilities(esp, insulator) indirectly on power distribution lines at a certain distance apart. This paper describes the proto type equipment to detect a faulty insulator by receiving a electric discharge noises, which are generated with a periodicity of 120Hz.

  • PDF

오손물질에 따른 고분자 장간애자의 표면 전계분포 (Electric field distribution on the surface of polymer post insulator according to state of water drops)

  • 장동욱;한문섭;김형철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1418-1419
    • /
    • 2007
  • In order to check the electric field distribution of polymer line post insulator, we performed electric field simulation according to state of water drops. Sea water is used to the contaminant. Electric field analysis is performed with change of contact angle, number and distance of water drops.

  • PDF

변전소용 애자의 신뢰성 평가를 위한 특성 분석 (Characteristics of the Solid-core Station Post Insulators for the Reliability Estimation)

  • 김찬영;송일근;김주용;이병성;정종욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.149-151
    • /
    • 2001
  • This paper presents the results of characteristics of the solid-core and suspension insulators for the reliability estimation. The various analytic techniques. such as ICP, XRD, SEM, EDS, were applied for the purpose. The alumina content of solid-core insulator was less than that of suspension insulator The cristobolite was crystallized only in solid-core insulator. The average pore size of solid-core insulator was larger than that of suspension insulator. However, the numbers of pore were fewer in the solid-core insulator.

  • PDF

Effects of One-Time Post-Annealing(OPTA) Process on the Electrical Properties of Metal- Insulator-Metal Type Thin-Film

  • Lee, Myung-Jae;Chung, Kwan-Soo
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.273-276
    • /
    • 2001
  • The origin of image-slicking in metal-insulator-metal type thin-film-diode(TFD) LCDs is the asymmetric current-voltage(I-V) characteristic of TFD element. we developed that MIM-LCDs have reduced-image-sticking and perfect symmetry characteristic. One-Time Post-Annealing (OPTA) heat treatment process was introduced to reduce the asymmetry and shift of the I-V characteristics, respectively. OPTA means that the whole layers of lower metal, insulator, and uuper metal are annealed at one time. The treatment temperatures and fabricated process of TFD element were under foot. Also, this low temperature fabricated process allows the application of plastic substrates.

  • PDF

피뢰기 절연행거의 기계적 강도 특성 (Mechanical Strength Properties of Hanger Insulator for Arrestor)

  • 박기호;조한구;한동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.589-592
    • /
    • 2001
  • Generally, hanger insulator for polymer arrestor have to be good insulation properties and mechanical strength and weatherability, But many remark and repairs have been to think about low cost and light weight. The Paper is used Polymer arrestor for post and performance analysis and mechanical strength insulator hanger according to development of simplest product. To enhance the efficiency of experimental modal analysis, we proposed the process which is the selection of the locations and the number of measurement points for pre-test.

  • PDF