• Title/Summary/Keyword: Positional relationship

Search Result 89, Processing Time 0.019 seconds

THE POSTOPERATIVE CONDYLAR POSITION RELATED TO TEMPOROMANDIBULAR DISCOMFORT IN SAGITTAL SPLIT RAMUS OSTEOTOMY (하악지 시상 분할술에 있어 술후 하악과두의 위치와 측두 하악관절장애)

  • You, Jun-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.2
    • /
    • pp.130-134
    • /
    • 1997
  • The sagittal split ramus osteotomy(SSRO) of the mandible has used one of the most popula methods for the correction of various dentofacial deformities, especially mandibular prognathism. In SSRO, there are produced bony gap following mandible setback because of mandibular flaring. For this reason, the condylar axis may be changed due to bony approximation both segment in three dimension more mesio-laterally. According to change of condylar position, the condition of TMJ structure are changed and change of TMJ symptoms are suggested theoretically, and the correction of malocclusion by SSRO may improve the TMJ symptoms by improvement of feeding difficulties. The pupose of this study was to determine relationship between expected alterations in condylar position and suggested TMJ symptoms produced by change of condylar position. TMJ symptoms of 15patients who had operated SSRO are checked at about postoperative 6 month ranging $5{\sim}11$ month. Anterior-posterior position of condyle which was comparison preoperative with postoperative position, was classified 5 groups. The author tried to identify relationship between positional change of condyle and TMJ discomfort.

  • PDF

Mesial Angulation of Upper Anterior Teeth Crown : Positional Relationship between Pupil and Mesial Inclination Line of Upper Canine (상악 전치 치관의 근심경사도: 견치 근심경사선과 동공의 위치적 관계)

  • Oh, Sang-Chun;Um, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.135-141
    • /
    • 2004
  • Statement of problem: Arrangement and angulation of clinical crown is very important for esthetic restoration in the upper anterior dentition. However, there was no clinical criteria to mesial angulation of the crown for Korean. Purpose: This study was undertaken to estimate the mesial angulation of the crown of the anterior teeth and the Oh's E-triangle made of the inter-pupillary line and the mesial inclination lines of the canines. Material and Method: 270 portraits of Korean were used for this study. The mesial angulation of the upper anterior teeth and the relationship of the inter-pupillary line and the mesial inclination lines of the canines were measured with the tools of PhotoShop software on the scanned images. Results: The angulation between the clinical crowns having a same name in the upper anterior dentition were $3.6^{\circ}$ between the central incisors, $8.6^{\circ}$ between the lateral incisors, and $13.6^{\circ}$ between the canines. There was no significance according to occupation and gender( P > 0.05). The ratio of height to base line of Oh's E-triangle was 4.47. 81.6% of the subjects showed the mesial inclination line of the canine passed by mesial border area of pupil. Conclusion: These data for Korean would be useful clinically to give the esthetic arrangement and to make the contour of upper anterior teeth.

The effects of performance, legitimacy, and reference group on strategic positional change - Evidence from North American Crude Petroleum and Natural Gas Industry - (성과 피드백, 정당성, 그리고 준거집단 성과가 리포지셔닝에 미치는 영향 - 북미 원유 및 천연가스 산업 분석을 중심으로 -)

  • Choi, Sung-Ho
    • Management & Information Systems Review
    • /
    • v.36 no.3
    • /
    • pp.17-35
    • /
    • 2017
  • This study investigates the determinants of strategic positional change. Specifically, the study suggests performance feedback affects to a firm's strategic repositioning. Performance feedback is a concept that a firm decides whether success or not by comparing its performance relative to its aspiration level. Prior studies successively discover diverse behaviors. The study suggests three unexplored relationships between performance gaps and strategic positioning. First, when a firm's performance is below relative to its aspiration level, that firm's strategic position will be deviate from the industry norm. Second, as the degree of industrial density increases, the tendency that a firm's strategic position becomes deviate from the industry norm decreases. Third, when the degree of reference group's performance decreases, the tendency that a firm's strategic position becomes deviate from the industry norm decreases. For empirical analysis, this study examines data of 538 firms that in North America crude petroleum and natural gas industry. The result reveals that the direction of a firm's strategic change is shaped when firms' performance is below relative to aspiration level. Also, this relationship is moderated as industrial density changes or when reference groups' performance decreases. This study contributes to the current literature by explaining how a firms' strategic position is decided. Also, this study reveals that reference groups' performance could affect to organizational choice.

  • PDF

Comparison Among Sensor Modeling Methods in High-Resolution Satellite Imagery (고해상도 위성영상의 센서모형과 방법 비교)

  • Kim, Eui Myoung;Lee, Suk Kun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6D
    • /
    • pp.1025-1032
    • /
    • 2006
  • Sensor modeling of high-resolution satellites is a prerequisite procedure for mapping and GIS applications. Sensor models, describing the geometric relationship between scene and object, are divided into two main categories, which are rigorous and approximate sensor models. A rigorous model is based on the actual geometry of the image formation process, involving internal and external characteristics of the implemented sensor. However, approximate models require neither a comprehensive understanding of imaging geometry nor the internal and external characteristics of the imaging sensor, which has gathered a great interest within photogrammetric communities. This paper described a comparison between rigorous and various approximate sensor models that have been used to determine three-dimensional positions, and proposed the appropriate sensor model in terms of the satellite imagery usage. Through the case study of using IKONOS satellite scenes, rigorous and approximate sensor models have been compared and evaluated for the positional accuracy in terms of acquirable number of ground controls. Bias compensated RFM(Rational Function Model) turned out to be the best among compared approximate sensor models, both modified parallel projection and parallel-perspective model were able to be modelled with a small number of controls. Also affine transformation, one of the approximate sensor models, can be used to determine the planimetric position of high-resolution satellites and perform image registration between scenes.

Diagnostic imaging analysis of the impacted mesiodens (매복 정중치의 진단영상분석)

  • Noh, Jeong-Jun;Choi, Bo-Ram;Jeong, Hwan-Seok;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.2
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose : The research was performed to predict the three dimensional relationship between the impacted mesiodens and the maxillary central incisors and the proximity with the anatomic structures by comparing their panoramic images with the CT images. Materials and Methods : Among the patients visiting Seoul National University Dental Hospital from April 2003 to July 2007, those with mesiodens were selected (154 mesiodens of 120 patients). The numbers, shapes, orientation and positional relationship of mesiodens with maxillary central incisors were investigated in the panoramic images. The proximity with the anatomical structures and complications were investigated in the CT images as well. Results : The sex ratio (M : F) was 2.28 : 1 and the mean number of mesiodens per one patient was 1.28. Conical shape was 84.4% and inverted orientation was 51.9%. There were more cases of anatomical structures encroachment, especially on the nasal floor and nasopalatine duct, when the mesiodens was not superimposed with the central incisor. There were, however, many cases of the nasopalatine duct encroachment when the mesiodens was superimpoised with the apical 1/3 of central incisor (52.6%). Delayed eruption (55.6%), crown rotation (66.7%) and crown resorption (100%) were observed when the mesiodens was superimposed with the crown of the central incisor. Conclusion : It is possible to predict three dimensional relationship between the impacted mesiodens and the maxillary central incisors in the panoramic images, but more details should be confirmed by the CT images when necessary.

Relationship in Shape between Oral and Pharyngeal Structures and Upper Cervical Spine (구강-인두형태와 상경추부형태간의 관계)

  • 한경수;김병욱;김문규
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.4
    • /
    • pp.457-473
    • /
    • 1998
  • This study was performed to investigate the morophological and positional correlation between the upper cervical vertebra, the oral structures and the pharyngeal tissues, and the correlation of these anatomical structures with dental features, such as teeth wear area nad tooth contact status, etc. Seventy patients with temporamandibular disorders and sixty three dental students without any signs and symptoms in head and neck region were selected for this study. All they had natural dentition without any fixed and removable protheses. Teeth wear area and arch width wre measured from the upper dental cast, tooth contact status were observed by T-Scan system$^\textregistered$ and four cephaloradiograpohs were taken from four head postures, namely, natural(NHP), forward(FHP), upward(UHP), and downward head postiure(DHP). 22 cephalometric items were measured on the films and the data were processed with SAS statistical program. The result of this study were as follows : 1. In normal group, angle of cervical vertebra tangent and of between hard and soft palate were broader in female subjects than those in male subjacets, but distance from subocciput to axis, size of soft palate, and pharyngeal space width were larger in male subjects. 2. In normal group with natural head posture, the items correlated each others from the three anatomical regions were distance between first nad second vertebra in posterior part, distance from the lingual surface of lower anterior teeth to anterior surface of soft palate, and distance from the hyoid bone to third vertebra. 3. Three set of items showed significant correlation each other in the four head postures in normal group. First set was the angle between hard and soft palate and the idstance from subocciput to posterior arch of first vertebra, second set was the distance between first and second vertebra in posterior part and the teeth wear area, third set was number and force of tooth contact and length of soft palate and distance from anterior tip of hyoid bone to mandibular plane.

  • PDF

A RADIOGRAPHIC STUDY ON THE MANDIBULAR CANAL (하악관에 관한 방사선학적 연구)

  • Cho Seung-Eun;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.307-316
    • /
    • 1991
  • The purpose of this study is to improve the availabilities of radiographic technics as diagnostic method related to mandibular canal in dental clinic. For this study 12 dry mandibles were used and 12 orthopantomograms were taken for measuring the gonial angle and the angle of mandibular canal to inferior border of mandible. 12 sites located between the 1st premolar to the 3rd molar region of 3dry mandibles were selected randomly, for measuring the vertical image magnification rates on three films; intraoral film, orthopantomogram, and computed tomogram, respectively and the thickness of cortical bone, and for observing bucco-lingually and supero-inferiorly location of the mandibular canal. The acquired results were as follows: 1. The means of the gonial angle and the angle of mandibular canal to inferior border of mandible were 123.9° and 143.5° And the two angles of dry mandible in alveolar crest stage were greater than in alveolar socket stage. 2. The vertical image length on intraoral film by paralleling technic was magnified by 3.07% on the average, the length on orthopantomogram by 18.49%, and the length on computed tomogram by 0.27%. 3. Observation of the bucco-lingually positional relationship of the mandibular canal was impossible by occlusal projection with the cross section technic and intraoral standard projection with the Clack's rule, however, possible by computed tomogram. 4. The thickness of the cortical bone of mandible was thickest in inferior border, and thicker by 6.59% at buccal side than at lingual side.

  • PDF

A RADIOGRAPHIC STUDY ON THE MORPHOLOGY OF THE MAXILLARY SINUS (상악동의 형태에 관한 방사선학적 연구)

  • Kim Bong-Young;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.297-306
    • /
    • 1991
  • The purpose of this study is to improve the availabilities of radiographic technics as diagnostic methods to evaluate maxillary sinus in dental clinic. For the morphologic study of maxillary sinus, 20 dry maxillas were used and intraoral standard views, orthopantomograms, and skull P-A views were taken. For measuring the vertical image magnification rates, 5 sites in maxillary molar regions of 5 dry mandibles were selected radndomly and 25 wires of the determined sizes for selected portions were attached to the sites, after then, intraoral radiograms with bisecting technic and orthopantomograms were taken. The acquired results were as follows: 1. The anterior extension of the maxillary sinus on orthopantomogram was the distal side of the canine in 45.45% of subjects, the mesial side of the canine in 27.27%, the lateral incisor in 9.09%, the mesial side of the 1st premolar in 9.09%, and the mesial side of the 2nd pre-molar in 9.09%. 2. The positional relationship between the floor of maxillary sinus and the apex of alveolar socket revealed superimposed type in 58.3% of subjects, approached type in 33.3%, and separated type in 8.4%. 3. The morphology of inferior border of maxillary sinus was simple V or U shape in edentulous stage and V or wide U shape in alveolar socket stage. 4. The vertical image length on intraoral film taken by bisecting technic was magnified by 27.23% on the average and the length on orthopantomogram by 12.35%. 5. The inferior borders of maxillary sinus coinciding with each of the areas bearing the anterior and the posterior teeth on skull P-A view were determined.

  • PDF

EFFECT OF IMPRESSION TECHNIQUES ON ACCURACY OF MASTER CASTS FOR IMPLANT PROSTHESES (인상채득 방법이 임플란트 보철 작업모형의 정확도에 미치는 영향)

  • Hong Eun-Hee;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.445-454
    • /
    • 1994
  • Osseointegrated implant prostheses are to provide normal function without compromising the unique interaction between the tissue and the implant. The essential requirement for the osseointegrated implant prostheses is passive fit of abutment. Therefore, the impression must be accurate and reproduciable since the resultant master cast precisely duplicates the clinical condition. The purpose of this study was to compare the accuracy of the master casts obtained from five impression techniques. Group 1 : To take impression with indirect technique and Impregum F. Group 2 : To take impression with unsplinted direct technique and Impregum F. Group 3 : To take impression with splinted direct technique and Impregum F. Group 4 : To take impression with unsplinted direct technique and Xanthano. Group 5 : To take impression with splinted dierct technique and Xanthano. The results were as follow : 1. In taking impression of Impregum F, there was no significant difference between to use of indirect technique and unsplinted direct technique.(p<0.05) 2. Unsplinted direct technique with Impregum F is less accurate than splinted direct technique with Impregum F or Xanthano and unsplinted direct technique with Xanthano.(p<0.05). 3. There was no significant difference between splinted direct technique with Impregum F and unsplinted direct technique with Xanthano.(p<0.05) 4. Splinted direct technique reproduce more accurate than unsplinted direct technique.(p<0.05) 5. Impression plaster produced less distortion than polyether.(p<0.05) As a result, splinted direct technique with Xanthano was the most accurate technique. As a result, splinted direct technique with Xanthano was the most accurate technique in this study. In addition to dimensinal changes in the materials used, positional errors were also attributed to the mechanical components used in the transfer porocess. Although the errors measured were relatively small, this study demonstrates the potential for distortions with the transfer technique used. Further study is indicated that ?the technique will be able to reproduce the intraoral relationship of implant fixtures reliably and predictably.

  • PDF

Acceptance Test and Clinical Commissioning of CT Simulator

  • An, Hyun Joon;Son, Jaeman;Jin, Hyeongmin;Sung, Jiwon;Chun, Minsoo
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.160-166
    • /
    • 2019
  • This study examined the clinical use of two newly installed computed tomography (CT) simulators in the Department of Radiation Oncology. The accreditation procedure was performed by the Korean Institute for Accreditation of Medical Imaging. An Xi R/F dosimeter was used to measure the CT dose index for each plug of the CT dose index phantom. Image qualities such as the Hounsfield unit (HU) value of water, noise level, homogeneity, existence of artifacts, spatial resolution, contrast, and slice thickness were evaluated by scanning a CT performance phantom. All test items were evaluated as to whether they were within the required tolerance level. CT calibration curves-the relationship between CT number and relative electron density-were obtained for dose calculations in the treatment planning system. The positional accuracy of the lasers was also evaluated. The volume CT dose indices for the head phantom were 22.26 mGy and 23.70 mGy, and those for body phantom were 12.30 mGy and 12.99 mGy for the first and second CT simulators, respectively. HU accuracy, noise, and homogeneity for the first CT simulator were -0.2 HU, 4.9 HU, and 0.69 HU, respectively, while those for second CT simulator were 1.9 HU, 4.9 HU, and 0.70 HU, respectively. Five air-filled holes with a diameter of 1.00 mm were used for assessment of spatial resolution and a low contrast object with a diameter of 6.4 mm was clearly discernible by both CT scanners. Both CT simulators exhibited comparable performance and are acceptable for clinical use.