• Title/Summary/Keyword: Point defect

Search Result 492, Processing Time 0.027 seconds

A Study on Defect Diagnostics of Gas-Turbine Engine on Off-Design Condition Using Genetic Algorithms (유전 알고리즘을 이용한 탈 설계 영역에서의 항공기용 가스터빈 엔진 결함 진단)

  • Yong, Min-Chul;Seo, Dong-Hyuck;Choi, Dong-Whan;Roh, Tae-Seong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.3
    • /
    • pp.60-67
    • /
    • 2008
  • In this study, the genetic algorithm has been used for the real-time defect diagnosis on the operation of the aircraft gas-turbine engine. The component elements of the gas-turbine engine for consideration of the performance deterioration consist of the compressor, the gas generation turbine and the power turbine. Compared to the on-design point, the teaming data has been increased 200 times in case off-design conditions for the altitude, the flight mach number and the fuel consumption. Therefore, enormous learning time has been required for the satisfied convergence. The optimal division has been proposed for learning time decrease as well as the high accuracy. As results, the RMS errors of the defect diagnosis using the genetic algorithm have been confirmed under 5 %.

Reconstruction of a scalp defect due to cochlear implant device extrusion using a temporoparietal fascia flap and a split-thickness skin graft from the scalp

  • Kang, Jae Kyoung;Lee, Jae Seong;Suh, Michelle;Lim, Gil Chae;Shin, Myoung Soo;Yun, Byung Min
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.5
    • /
    • pp.319-323
    • /
    • 2019
  • Cochlear implant extrusion, which is a common complication of cochlear implants, is generally repaired by a well visualized soft-tissue flap. A 61-year-old female patient with a medical history of schizophrenia who had a skin ulcer that caused cochlear implant extrusion, but that would be a stronger statement was referred to our department for removal of the implant and reconstruction of the resultant scalp defect. Accordingly, the broad defect was covered via rotation of a temporoparietal fascia flap (TPFF) using the superficial temporal artery, with the pedicle in the preauricular region as the pivot point. Coverage of TPFF was achieved with a split-thickness skin graft using the scalp as the donor site, which led to a quick recovery after the operation and satisfactory results in terms of aesthetics. This case suggests that a TPFF might be used as a flexible flap with low donor site morbidity for reconstructing cases of cochlear implant extrusion accompanied by a large full-layer scalp defect.

Are critical size bone notch defects possible in the rabbit mandible?

  • Carlisle, Patricia L.;Guda, Teja;Silliman, David T.;Hale, Robert G.;Baer, Pamela R. Brown
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.2
    • /
    • pp.97-107
    • /
    • 2019
  • Objectives: Small animal maxillofacial models, such as non-segmental critical size defects (CSDs) in the rabbit mandible, need to be standardized for use as preclinical models of bone regeneration to mimic clinical conditions such as maxillofacial trauma. The objective of this study is the establishment of a mechanically competent CSD model in the rabbit mandible to allow standardized evaluation of bone regeneration therapies. Materials and Methods: Three sizes of bony defect were generated in the mandibular body of rabbit hemi-mandibles: $12mm{\times}5mm$, $12mm{\times}8mm$, and $15mm{\times}10mm$. The hemi-mandibles were tested to failure in 3-point flexure. The $12mm{\times}5mm$ defect was then chosen for the defect size created in the mandibles of 26 rabbits with or without cautery of the defect margins and bone regeneration was assessed after 6 and 12 weeks. Regenerated bone density and volume were evaluated using radiography, micro-computed tomography, and histology. Results: Flexural strength of the $12mm{\times}5mm$ defect was similar to its contralateral; whereas the $12mm{\times}8mm$ and $15mm{\times}10mm$ groups carried significantly less load than their respective contralaterals (P<0.05). This demonstrated that the $12mm{\times}5mm$ defect did not significantly compromise mandibular mechanical integrity. Significantly less (P<0.05) bone was regenerated at 6 weeks in cauterized defect margins compared to controls without cautery. After 12 weeks, the bone volume of the group with cautery increased to that of the control without cautery after 6 weeks. Conclusion: An empty defect size of $12mm{\times}5mm$ in the rabbit mandibular model maintains sufficient mechanical stability to not require additional stabilization. However, this defect size allows for bone regeneration across the defect. Cautery of the defect only delays regeneration by 6 weeks suggesting that the performance of bone graft materials in mandibular defects of this size should be considered with caution.

Forehead Island Flap For Nasal Reconstruction (이마 섬피판을 이용한 코재건술)

  • Lee, Keun-Cheol;Kwon, Yong-Seok;Jung, Ki-Hwan;Han, Jae-Jung;Park, Jung-Min;Kim, Seok-Kwun
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.199-204
    • /
    • 2005
  • The nose is the most prominent area of the face, therefore susceptible to trauma and skin cancer. When small sized defect is in nasal tip, it results in disturbance of the facial harmony even if replantation, composite graft, skin graft or median forehead flap has been used for the reconstruction. So it is needed that the best method reconstruction is performed according to the degree of defect or deformity. And at the same time the physiology and anatomy of nose were clarified and its aesthetic subunits were employed. How can we cover the about 3 cm sized nasal defect in nasal tip with cartilage exposure? At first, we can think forehead island flap is most appropriate. We performed 7 cases of the forehead island flap for reconstruction of the defect in nasal tip(4 cases: cancer, 3 cases: trauma) from March, 2001 to August, 2004. This result was satisfactory in the point of texture, color, donor scar, and there were no complication such as wound disruption, infection, flap atrophy, and hematoma. The advantages of forehead island flap are: 1) No injury of deep vessel and nerve, 2) control of shape and volume, 3) Short operation time, 4) primary closure of donor site, 5) one stage operation. Also, forehead island flap can cover the defect in nose where skin graft and local flap can not cover. But, operator always must take care for flap congestion and donor site scar. We thought forehead island flap is one of the best option of reconstruction of nasal tip defect.

Segmented Ulnar Transposition to Defect of Ipsilateral Radius in the Forearm (전완골 분절의 전위 이식술)

  • Chung, Duke-Whan;Han, Soo-Hong;Lee, Jae-Hoon;Kwon, Boo-Kyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.2
    • /
    • pp.125-132
    • /
    • 2007
  • Introduction: Ulna is nearly equal to radius in function and bony architecture and strength in forearm. But in lower extremity, fibula is 1/5 of tibia in anatomic and functional point so we can find fibula transposition is commonly used in defect of tibia. We cannot find other article about segmental forearm bone transposition in man. The purpose of this study was to report our clinical and functional result of undergoing segmented transposition of ipsilateral ulna with its own vascular supply in defect of radius in 6 cases. Material and method: From June 1994 to October 2007, 7 segmented bone transpositional grafts in forearm were performed in Kyung Hee Medical Center. The distribution of age was from 20 years old to 73 years old. There was male in 6 cases and female in 1 case. The causes of operation were giant cell tumor in 1 case and traumatic origin in 6 cases; it was nonunion in 2 cases and fracture with severe comminution in 4 cases. Ipsilaterally segmented ulna keeping its own vascular supply was transported to defect of radius in severe traumatic patients and one patient whose tumor in radius had been excised. Transported ulna was fixed to proximal and distal radius remnants by plate and screw. In one case with giant cell tumor, transported ulna was connected to radius across wrist joint as wrist joint fusion. Joint preserving procedures were performed in 6 cases with crushing injury of radius. Results: We could obtain solid bony union in all cases and good functional results. The disadvantage was relative shortening of forearm, but we could overcome this problem. Conclusion: We think that ipsilateral segmented ulna transposition keeping its own vascular supply to radius can be perfomed with one of procedures in cases with wide defect in radius.

  • PDF

A Study on Sensor Data Analysis and Product Defect Improvement for Smart Factory (스마트 팩토리를 위한 센서 데이터 분석과 제품 불량 개선 연구)

  • Hwang, Sewong;Kim, Jonghyuk;Hwangbo, Hyunwoo
    • The Journal of Bigdata
    • /
    • v.3 no.1
    • /
    • pp.95-103
    • /
    • 2018
  • In recent years, many people in the manufacturing field have been making efforts to increase efficiency while analyzing manufacturing data generated in the process according to the development of ICT technology. In this study, we propose a data mining based manufacturing process using decision tree algorithm (CHAID) as part of a smart factory. We used 432 sensor data from actual manufacturing plant collected for about 5 months to find out the variables that show a significant difference between the stable process period with low defect rate and the unstable process period with high defect rate. We set the range of the stable value of the variable to determine whether the selected final variable actually has an effect on the defect rate improvement. In addition, we measured the effect of the defect rate improvement by adjusting the process set-point so that the sensor did not deviate from the stable value range in the 14 day process. Through this, we expect to be able to provide empirical guidelines to improve the defect rate by utilizing and analyzing the process sensor data generated in the manufacturing industry.

Coordinate Measuring Technique based on Optical Triangulation using the Two Images (두장의 사진을 이용한 광삼각법 삼차원측정)

  • 양주웅;이호재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.76-80
    • /
    • 2000
  • This paper describes a coordinate measuring technique based on optical triangulation using the two images. To overcome the defect of structured light system which measures coordinate point by point, light source is replaced by CCD camera. Pixels in CCD camera were considered as virtual light source. The overall geometry including two camera images is modeled. Using this geometry, the formula for calculating 3D coordinate of specified point is derived. In a word, the ray from a virtual light source was reflected on measuring point and the corresponding image point was made on the other image. Through the simulation result, validation of formula is verified. This method enables to acquire multiple points detection by photographing.

  • PDF

Electronic Structure and Magnetism of Fe Monolayer with Periodic Defects (주기적 결함을 가진 철 단층의 전자구조와 자성)

  • Landge, Kalpana K.;Bialek, Beata;Lee, Jae-Il
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.5
    • /
    • pp.161-164
    • /
    • 2009
  • The effect of periodic vacancies to the magnetism of the Fe monolayer was investigated by calculating the electronic structures using the full-potential linearized augmented plane wave method within the GGA approximation. We considered four types of vacancies, point defect, I type, + type, and H type which are consisted of one, three, five and seven vacant sites, respectively. We found that the Fe atoms nearest to the vacancy have the largest magnetic moment in each system, and the value of magnetic moment of the atom was increased as the number of vacancy site is increased. The value of the largest magnetic moment in the systems of point defect, I type, + type, and H type are 3.08, 3.09, 3.15, and 3.30 bohr magnetons, respectively.