• Title/Summary/Keyword: Point Heating System

검색결과 193건 처리시간 0.029초

냉각탑 백연방지의 성능 향상에 관한 실험적 연구 (An Experimental Study on the Cooling Tower of Plume Prevention and Performance Improvements)

  • 정순영;이병천;김성
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.578-584
    • /
    • 2019
  • The occurrence of white plume in the cooling tower is phenomenon that the steam in the air through the cooling tower fan is condensed again by the cold ambient air to become saturated moist air. Accordingly, this can cause many problems like spoiling landscape around the cooling tower, odor of ambient air, falling accident by frozenness in the winter, and traffic accident, etc. This study was to install the heat exchanger in the inside of the cooling tower in order to prevent the white plume phenomenon in the cooling tower without affecting the performance of cooling tower. In addition, this study was to discharge the part of cooling water into the atmosphere through the recirculation of heat exchanger after creating dry air by heating the saturated moist air to the dew point temperature. At that time, this study was to conduct the experimental study in order to secure the optimal design data to prevent the white plume in the cooling tower because it checked the dry·moist temperature and relative humidity in the inside·outside of cooling tower on the moist air, and evaluated the performance of the heat exchanger.

식육포장처리업의 HACCP 운용실태 분석 (Evaluation of HACCP system implementation in meat packaging industry)

  • 강천근;홍종해
    • 한국동물위생학회지
    • /
    • 제36권4호
    • /
    • pp.291-296
    • /
    • 2013
  • The purpose of this study was to determine food safety practices and procedures based on Hazard Analysis Critical Control Point (HACCP) system and to suggest more effective method of HACCP implementation in meat packaging industry in Korea. We used the non-compliance rate of each evaluation item to compare the weak points of prerequisite requirements and HACCP. The prerequisite items related to facility, equipment, and tools showed inadequate level of requirements or unsanitary conditions for proper HACCP operation. A lack of understanding of sanitation standard operation procedures was identified as a fundamental barrier to HACCP implementation. High rate of non-compliance in HACCP items compared to prerequisite requirements signify that small businesses have potential difficulties of applying HACCP due to lack of technical expertise, financial resources for prerequisite requirements, and available personnel to prepare and operate HACCP plan. Also we suggest to revise and minimize current critical control points (CCPs). Time-temperature control of cold-storage rooms for carcasses and final products could be performed by control points of prerequisite requirements. As the occurrence frequency getting lower, metal detector should be replaced by intensified training of sanitary handling and safety procedure. This will be more effective and preventive measures against physical contaminants including metal particles. In conclusion, control point of prerequisite requirement may replace CCP in the plant with simple processing line and no heating process such as meat packaging industry.

실내유입온기의 열유동특성과 고효율 축열에 관한 연구 (A Study on the Heat Flow Characteristics and High Efficiency Thermal Storage of Inflowing Warm Air in the Room)

  • 박이동;정운철;이도영
    • 태양에너지
    • /
    • 제17권2호
    • /
    • pp.13-22
    • /
    • 1997
  • 본 연구에서는 실내로 유입되는 온기와 실내공기사이의 온도차 및 유입속도에 따라 발생되는 부력의 영향 및 실내로 유입된 온기의 혼합특성에 관한 열유동특성을 파악하였다. 혼합도의 정의로부터 임계속도($1.2{\sim}1.6m/s$)전 후로 기하학적영향에 대하여서 혼합과의 관계를 파악할 수 있었다. 그리고 축열표율과의 관계는 속도가 크고 기준온도차가 작을수록 부력의 영향을 적게 받아서 아네모스형, 베인형 모두 높은 축열효율을 나타냈다. 그리고 속도가 클 때는 베인형이 전반적으로 우수한 축열효율을 나타냈다. 따라서 유입속도에 의한 영향이 기준온도차에 의한 영향보다 지배적임을 알 수 있었다.

  • PDF

신축건물 에너지효율관리를 위한 환경 및 에너지모니터링(계측) 방법론 (A Study on the BEMS Installation and performance Evaluation Method for Energy Monitoring(Measuring) of New Building)

  • 권원정;윤지혜;권동명
    • 에너지공학
    • /
    • 제27권2호
    • /
    • pp.32-48
    • /
    • 2018
  • 건물의 에너지사용량을 효율적으로 관리하기 위해서는 에너지의 사용에 대한 모니터링이 우선시 되어야 한다. 건물에서의 에너지사용량은 크게 에너지원별, 용도별, 구역별로 구분하여 관리할 수 있다. 에너지원별이란 건물의 설비를 가동하기 위해 공급되는 전기, 가스, 연료, 지역난방 등을 의미한다. 용도별이란 크게 냉방, 난방, 조명, 급탕, 환기와 같이 5대 용도로 구분할 수 있지만, 5대 용도 안에 포함시키기 어려운 엘리베이터나 전열기기 등은 별로도 분류하는 것을 의미한다. 이 외 구역별은 건물의 사용목적이나 사용용도가 비슷하거나 구분되는 지역을 묶어서 비교 관리 하거나 별도 관리 하는 것을 말한다. 이 밖에 에너지의 효율관리에서는 건물의 에너지사용량에 영향을 주는 온도, 습도와 재실자에 대한 관리가 필요하며, 최근 문제가 되는 미세먼지는 건물의 환기에 직접적인 영향을 주기 때문에 이에 대한 관리도 병행되어야 한다.

환상유로에 있어서 수직고온관의 과도적 냉각과정에 관한 연구 (A study on the transient cooling process of a vertical-high temperature tube in an annular flow channel)

  • 정대인;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.156-164
    • /
    • 1986
  • In the case of boiling on high temperature wall, vapor film covers fully or parcially the surface. This phenomenon, film boiling or transition boiling, is very important in the surface heat treatment of metal, design of cryogenic heat exchanger and emergency cooling of nuclear reactor. Mainly supposed hydraulic-thermal accidents in nuclear reactor are LCCA (Loss of Coolant Accident) and PCM (Power-Cooling Mismatch). Recently, world-wide studies on reflooding of high temperature rod bundles after the occurrence of the above accidents focus attention on wall temperature history and required time in transient cooling process, wall superheat at rewet point, heat flux-wall superheat relationship beyond the transition boiling region, and two-phase flow state near the surface. It is considered that the further systematical study in this field will be in need in spite of the previous results in ref. (2), (3), (4). The paper is the study about the fast transient cooling process following the wall temperature excursion under the CHF (Critical Heat Flux) condition in a forced convective subcooled boiling system. The test section is a vertically arranged concentric annulus of 800 mm long and 10 mm hydraulic diameter. The inner tube, SUS 304 of 400 mm long, 8 mm I.D, and 7 mm O.D., is heated uniformly by the low voltage AC power. The wall temperature measurements were performed at the axial distance from the inlet of the heating tube, z=390 mm. 6 chromel- alumel thermocouples of 76 .mu.m were press fitted to the inner surface of the heating tube periphery. To investigate the heat transfer characteristics during the fast transient cooling process, the outer surface (fluid side) temperature and the surface heat flux are computed from the measured inner surface temperature history by means of a numerical method for inverse problems of transient heat conduction. Present cooling (boiling) curve is sufficiently compared with the previous results.

  • PDF

회주철의 마찰용접 특성에 관한 연구 - 입열량 이론식을 중심으로 - (Friction Weldability of Grey Cast Iron - by the Concept of Friction Weld Heat Input Parameter -)

  • 정호신;방국수
    • Journal of Welding and Joining
    • /
    • 제32권3호
    • /
    • pp.95-101
    • /
    • 2014
  • Joining of grey cast iron by fusion welding has much difficulties for its extremely low ductility and low toughness because of the flake form of the graphite. And the brittle microstructure, i.e. ledeburite may be formed during fusion welding by its rapid cooling rates. By these kinds of welding problem, preheat and post heat treatment temperature must be increased to avoid weld crack or welding problems. In order to avoid these fusion welding problem, friction welding of cast iron was carried out for improving joint soundness, establishing friction welding variables. There is no factor for evaluating friction weldability in continuous drive type friction welding. In this point of view, this study proposed the parameters for calculating friction weld heat input. The results obtained are as follows ; 1. There was a close relationship between tensile strength and flash appearance of friction welded joint. 2. Tensile strength was decreased and flash was severely oxidized as increasing frictional heating time. 3. As increased forging pressure $P_2$, flash had a large crack and tensile strength was decreased. 4. As powdered graphite by rotational frictional force induced flat surface and hindered plastic flow of metal, tensile strength of welded joint was decreased. 5. Heat input for continuous drive type friction welding could be calculated by the factors of $P_1$, $P_2$ and upset distance(${\delta}$).

컴팩트형 VAV 공조기의 성능평가와 경제성 분석에 관한 연구 (A Study on Economic Analysis and Performance Appraisal of Compact Type Variable Air Volume)

  • 김동철;정광섭;김영일
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.44-49
    • /
    • 2015
  • Ceiling cooling and heating system that consider load arrangement and space in the ceiling needs to be developed. Therefore, experimental and economic changes were done to verify the performance of compact type VAV. The test results were as follow. 1) Noise test result, measuring approximately 50.4 dB~56.6 dB (before ceiling in landfill), had a better ceiling deadline than the current measure, about a 10 dB noise reduction, so that the office baseline (40~50 dB) noise was judged to be less than test. 2) For the static pressure test result, taking out an outside hydrostatic 25 mmAq, 24.8 mmAq was measured, respectively, at the point. 3) For the life-cycle cost analysis result, the initial investment cost, maintenance replacement costs, and maintenance costs increased 0.2%, but the energy savings ratio was 19.5% while the whole life cycle savings of 40 years LCC was reduced 11.9%.

연료전지용 열분해 개질기의 이론해석 및 설계연구 (Theoretical Analysis and Study of Design of Autothermal Reformer for Use in Fuel Cell)

  • 강일환;김형만;최갑승;왕학민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.58-63
    • /
    • 2005
  • As fuel cells approach commercialization, hydrogen production becomes a critical step in the overall energy conversion pathway. Reforming is a process that produces a hydrogen-rich gas from hydrocarbon fuels. Hydrogen production via autothermal reforming (ATR) is particularly attractive for applications that demand a quick start-up and response time in a compact size. However, further research is required to optimize the performance of autothermal reformers and accurate models of reactor performance must be developed and validated. The design includes the requirement of accommodating a wide range of experimental set ups. Factors considered in the design of the reformer are capability to use multiple fuels, ability to vary stoichiometry, precise temperature and pressure control, implementation of enhancement methods, capability to implement variable catalyst positions and catalyst arrangement, ability to monitor and change reactant mixing, and proper implementation of data acquisition. A model of the system was first developed in order to calculate flowrates, heating, space velocity, and other important parameters needed to select the hardware that comprises the reformer. Predicted performance will be compared to actual data once the reformer construction is completed. This comparison will quantify the accuracy of the model and should point to areas where further model development is required. The end result will be a research tool that allows engineers to optimize hydrogen production via autothermal reformation.

  • PDF

3차원 적층 집적회로에서 구리 TSV가 열전달에 미치는 영향 (The Effects of Cu TSV on the Thermal Conduction in 3D Stacked IC)

  • 마준성;김사라은경;김성동
    • 마이크로전자및패키징학회지
    • /
    • 제21권3호
    • /
    • pp.63-66
    • /
    • 2014
  • 본 연구에서는 3차원 적층 집적회로 구조에서 Cu TSV를 활용한 열관리 가능성에 대해 살펴보았다. Cu TSV가 있는 실리콘 웨이퍼와 일반 실리콘 웨이퍼 후면부를 점열원을 이용하여 가열한 후 전면부의 온도 변화를 적외선 현미경을 이용하여 관찰하였다. 일반 실리콘 웨이퍼의 경우 두께가 얇아지면서 국부적인 고온영역이 관찰됨으로서 적층 구조에서 층간 열문제의 가능성을 확인할 수 있었다. TSV 웨이퍼의 경우 일반 실리콘 웨이퍼보다 넓은 영역의 고온 분포를 나타내었으며, 이는 Cu TSV를 통한 우선적인 열전달로 인한 것으로 적층 구조에서 Cu TSV를 이용한 효과적인 열관리의 가능성을 나타낸다.

구동 신호 Phasor 제어형 SIT 고주파 공진 인버터 (Drive Signal Phasor Control-Based High Frequency Resonant Inverter Using Power-SIT)

  • 김동희;노채균;김종해;정원영
    • 조명전기설비학회논문지
    • /
    • 제12권1호
    • /
    • pp.51-57
    • /
    • 1998
  • 본 논문은 구동신호 위상제어 기능을 갖는 SIT고주파공진 인버터를 제안하였다. SIT를 이용한 위상제어형인버터는 낮은 스위칭 손실로서 높은 스위칭 주파수의 전력변환을 실현시킬 수 있다. 특히 2단위 인버터의 출력전압을 직렬로 연결하여 높은 출력을 얻을 수 있다. 과전류에 대해서 보호회로를 이용한 시스템의 안정성과 그리고 PLL에 의해 부하변화에 따른 자동추종제어를 실현하였다. 특히 제안된 인버터는 고주파에서도 거의 정현파에 가까우며, 스위칭 주파수 범위는 180∼220〔kHz〕이고, 2〔kW〕의 유도가열에 응용하였다. 본 인버터의 동작 특성에 대해서 이론과 실험결과를 비교 검토하였다.

  • PDF