• Title/Summary/Keyword: Plate reinforcement

Search Result 415, Processing Time 0.031 seconds

Design Automation of Slab System by the Finite Element Method (유한요소법을 이용한 슬래브 시스템의 설계자동화)

  • 이성우
    • Computational Structural Engineering
    • /
    • v.4 no.4
    • /
    • pp.79-89
    • /
    • 1991
  • New design method of R/C slab system based on finite element method has been presented. The proposed method can substitute inaccurate existing method, which has limitation in its application, and provide accurate and efficient design results for any type of slab system. Isoparametric plate element used in the slab design has been efficiently formulated to save computational time. Reinforcement has been determined by strength design method and compared with code minimum values. Graphical output through comprehensive contour map for resulting moments and designed steel areas has considerably facilitated design process. Accurate shear results from isoparametric plate element enabled to check punching shear in a proper manner. In addition to strength design criteria, serviceability has also been checked by utilizing newly developed inelastic deflection multiplier method. An example for circular slab with opening showed that the proposed method could be applied to design of irregular slab without any difficulty.

  • PDF

A Study on the Preventive Measures against Local Vibrations of Ships' Deck Panels (선체갑판(船體甲板)의 국부진동(局部振動)에 대한 방진설계(防振設計)에 관한 연구(硏究))

  • K.C.,Kim;H.M.,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 1981
  • To contribute to the preventive measures against local vibrations of ship's deck panels, some investigations into the prediction method of the natural frequency of the vibration of stiffened plates were done. Firstly, an analytical method based on the orthotropic plate analogy and the Rayleigh method using eigenfunctions of the Euler beam was shown, and numerical results of a regularly stiffened plate were compared with experimental results. And then, the method was extended to stiffened plates having one or two irregular stiffeners to obtain an approximate formula showing the relation between the change of the natural frequency and the size of the irregular stiffeners. The latter case was investigated for the purpose of providing a convenient design manual applicable to cure of local resonant vibrations of ships' deck panels by additional reinforcement of one or two stiffeners. In the analytical development the boundary was assumed to be rigidly supported and elastically restrained against rotation. In the experiment, however, only an extreme case i.e. simply supported boundary was investigated. The results of the investigation show that there is a fairly good conformity between the analytical results and the experimental ones in the first case, and that the approximate formula for the second case is confirmed also to be reliable for the design purpose. Considering that actual boundary conditions of deck panels in ship structures lie mostly somewhere between the simple support and the fixed, the authors discussed problems of the joint efficiency at the boundary of deck panels from the viewpoint of the practical application of the formulae.

  • PDF

An Experimental Study on the Flexural Behavior of Reinforced Concrete Columns Strengthened with Wire Rope and T-Shape Steel Plate units (와이어로프와 T형 플레이트에 의해 보강된 RC 기둥의 휨 거동에 대한 실험적 연구)

  • Sim, Jae-Il;Yang, Keun-Hyeok;Oh, Sung-Jin;Byun, Hang-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.153-156
    • /
    • 2008
  • The objective of the present study is to evaluate the flexural behavior of reinforced concrete columns externally strengthened with wire rope and T-shape steel plate units. Three strengened columns and a control unstrengthened column were tested under cyclic lateral load simultaneously subjected to a constant axial load. All columns had same section size, and the arrangement of longitudinal reinforcement and internal hoop. The spacing of wire rope range from 40 ${\sim}$ 80mm, which corresponds from 1.0 ${\sim}$ 0.5, respectively, times the minium amount of hoop specified in seismic design of ACI 318-05. Test results showed that the proposed unbonded-type strengthening procedure is very effective for improving the flexural ductility of reinforced concrete columns.

  • PDF

Variability of Deflections for Reinforced Concrete Flat Plate (철근 콘크리트 플랫 플레이트 처짐의 변동성 평가)

  • Kim, Min Sook;Jo, Eunsun;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.6
    • /
    • pp.543-549
    • /
    • 2014
  • The deflection of reinforced concrete members can be highly variable, due to uncertainties in the characteristics of the concrete. However, current standards do not take this problem into account, instead recommending only the minimum thickness and maximum allowable deflections based on empirical data. This paper is aimed at evaluation deflection variabilities by applying a probabilistic analysis model to a finite element analysis model. To evaluate the variabilities of deflections, a Monte Carlo simulation, which incorporated the eight parameters related to concrete, reinforcement, member size, and tension stiffening. The results showed that lager spans were more sensitive to the deflection due to loads and that as the applied live loads were increases and the slab thickness were decreased, the deflection variability increased.

Flexural Behavior of RC Beams Strengthened with CFRP Plate Using Multi-directional Channel-type Anchorage System (다방향 채널형 단부정착장치를 이용한 CFRP판 보강 RC 보의 휨거동)

  • Hong, Ki Nam;Han, Sang Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.171-180
    • /
    • 2008
  • The aim of this paper is to clarify the structural performance of RC beams strengthened with Carbon Fibre Reinforced Polymer(CFRP) plates using channel-type anchorage system. Twelve RC beams were specifically designed without and with a channel-type anchorage system, which was carefully detailed to enhance the benefits of the strengthening plates. All the twelve beams were identical in terms of their geometry but varied in their internal reinforcement, concrete strength. All the beams were tested under four point bending and extensively instrumented to monitor strains, cracking, load capacity and failure modes. The structural response of all the twelve beams is then critically analyzed in terms of deformability, strength and failure processes. It is shown that with a channel-type anchorage system, a brittle debonding failure of a strengthened beam can be transformed to an almost ductile failure with well-defined enhancement of structural performance in terms of both deformation and strength.

Experimental Study on the Structural Capacity of the U-Flanged Truss Steel Beam (U-플랜지 트러스 보의 구조 내력에 관한 실험 연구)

  • Oh, Myoung Ho;Kim, Young Ho;Kang, Jae Yoon;Kim, Myeong Han
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.113-121
    • /
    • 2018
  • U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars. Upper flange and lower plate are connected by the diagonal lattice bars welded on the upper and lower sides. In this study the structural experiments on the U-flanged truss beams with various shapes of upper flange were performed, and the flexural and shear capacities of U-flanged truss beam in the construction stage were evaluated. The principal test parameters were the shape of upper flange and the alignment space of diagonal lattice bars. In all the test specimens, the peak loads were determined by the buckling of lattice bar regardless of the upper flange shape. The test results have shown that the buckling of lattice bar is very important design factor and there is no need to reinforce the basic u-shaped upper flange. However, the early lattice buckling occurred in the truss beam with upper steel bars because of the insufficient strength and stiffness of upper chord, and the reinforcement in the upper chord is necessary. The formulae of Eurocode 3 (2005) have presented more exact evaluations of lattice buckling load than those of KBC 2016.

Seam Efficiency of Geotextile and Verification of Allowable Bearing Capacity of Soft Ground (토목섬유 봉합효율과 연약지반 허용지지력 현장검증)

  • Cho, Dae-Sung;Chae, Yu-Mi;Kim, Jae-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.7
    • /
    • pp.25-34
    • /
    • 2021
  • Since the dredging reclaimed land consisting of soft ground is very weak in support, the difficult and complex factors should be considered in the design to calculate accurate bearing capacity of soft ground. Recently, various reinforcement construction methods of soft ground have been designed for dredged landfills, but the stabilities are predicted by calculating conventional Meyerhof (1974) equation for trafficability in soft ground. Conventional equations increase economic costs by underestimating bearing capacity of weak ground in order to ensure constructive safety, so a modified equation has been proposed from the literature. The paper attempts to experiment and compute important factors, such as stitching fiber and seam tensile strength of geotextiles, that are not theoretically considered and can be identified in the field. In addition, The evaluation of the bearing capacity of the modified equation is verified to be stable for trafficability through the plate bearing test performed on site.

Structural Analysis of CBS (Composite Basement Wall System)-RIB Underground Structures Using Numerical Modeling (수치해석을 통한 강합성 빔보강 지하 구조물의 거동분석)

  • Yoo, Han-Kyu;Kim, Yeon-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.6
    • /
    • pp.39-44
    • /
    • 2010
  • In case of the design method, which is used in the inside and outside of the country, on corrugated multi plate structures, section modulus would be determined by assuming 2-dementioanl equivalent section of those structures. However, it is impossible to consider 3-dimentional effects when 2-dimentional design method is applied since structures are reinforced with a pattern of the 1200, 1600 mm reinforcements except the 800 mm reinforcement. Thus, in this study, technical specification standard is analyzed for the existing corrugated multi plate design methods, and section strengths, moments, and so on of equivalent and practical sections are compared and estimated using 3-dimentional FEM (finite element method) for semicircles and architectural features widely used. Based on the results of that analysis, analytical basis for 3-dimentional design of the CBS-RIB is suggested.

Study on application case of reinforce building shallow foundation for soil stabilized materials using circulating resources (순환자원 활용 지반안정재의 건축물 얕은기초 보강 적용사례 연구)

  • Song, Sang-Huwon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.457-462
    • /
    • 2022
  • This study is about the case applied of a shallow foundation reinforcement method for a low/mid-rise building where a relatively small load is applied by using a soil stabilized material that utilizes recycled resources. First, laboratory mixing test was conducted for four mixing ratios in order to derive the optimal mixing ratio in the field. Using the derived optimal mixing ratio, it was applied as a shallow foundation for the building in the field. The field application method used a simple process of compaction by the soil mixedure with the original soil and the soil stabilized material in the field. After field application, a plate bearing test was performed on one original ground and two improved ground to confirm the allowable bearing capacity. As a result of checking the bearing capacity, it was found that sufficient bearing capacity was exhibited.Therefore, it was confirmed that it can be used as a shallow foundation for the building.

Using DQ method for vibration analysis of a laminated trapezoidal structure with functionally graded faces and damaged core

  • Vanessa Valverde;Patrik Viktor;Sherzod Abdullaev;Nasrin Bohlooli
    • Steel and Composite Structures
    • /
    • v.51 no.1
    • /
    • pp.73-91
    • /
    • 2024
  • This paper has focused on presenting vibration analysis of trapezoidal sandwich plates with a damaged core and FG wavy CNT-reinforced face sheets. A damage model is introduced to provide an analytical description of an irreversible rheological process that causes the decay of the mechanical properties, in terms of engineering constants. An isotropic damage is considered for the core of the sandwich structure. The classical theory concerning the mechanical efficiency of a matrix embedding finite length fibers has been modified by introducing the tube-to-tube random contact, which explicitly accounts for the progressive reduction of the tubes' effective aspect ratio as the filler content increases. The First-order shear deformation theory of plate is utilized to establish governing partial differential equations and boundary conditions for the trapezoidal plate. The governing equations together with related boundary conditions are discretized using a mapping-generalized differential quadrature (GDQ) method in spatial domain. Then natural frequencies of the trapezoidal sandwich plates are obtained using GDQ method. Validity of the current study is evaluated by comparing its numerical results with those available in the literature. After demonstrating the convergence and accuracy of the method, different parametric studies for laminated trapezoidal structure including carbon nanotubes waviness (0≤w≤1), CNT aspect ratio (0≤AR≤4000), face sheet to core thickness ratio (0.1 ≤ ${\frac{h_f}{h_c}}$ ≤ 0.5), trapezoidal side angles (30° ≤ α, β ≤ 90°) and damaged parameter (0 ≤ D < 1) are carried out. It is explicated that the damaged core and weight fraction, carbon nanotubes (CNTs) waviness and CNT aspect ratio can significantly affect the vibrational behavior of the sandwich structure. Results show that by increasing the values of waviness index (w), normalized natural frequency of the structure decreases, and the straight CNT (w=0) gives the highest frequency. For an overall comprehension on vibration of laminated trapezoidal plates, some selected vibration mode shapes were graphically represented in this study.