Browse > Article
http://dx.doi.org/10.7843/kgs.2010.26.6.39

Structural Analysis of CBS (Composite Basement Wall System)-RIB Underground Structures Using Numerical Modeling  

Yoo, Han-Kyu (Dept. of Civil & Environmental Engrg., Hanyang Univ.)
Kim, Yeon-Sung (Dept. of Civil Engrg., Hanyang Univ.)
Publication Information
Journal of the Korean Geotechnical Society / v.26, no.6, 2010 , pp. 39-44 More about this Journal
Abstract
In case of the design method, which is used in the inside and outside of the country, on corrugated multi plate structures, section modulus would be determined by assuming 2-dementioanl equivalent section of those structures. However, it is impossible to consider 3-dimentional effects when 2-dimentional design method is applied since structures are reinforced with a pattern of the 1200, 1600 mm reinforcements except the 800 mm reinforcement. Thus, in this study, technical specification standard is analyzed for the existing corrugated multi plate design methods, and section strengths, moments, and so on of equivalent and practical sections are compared and estimated using 3-dimentional FEM (finite element method) for semicircles and architectural features widely used. Based on the results of that analysis, analytical basis for 3-dimentional design of the CBS-RIB is suggested.
Keywords
CBS-RIB Structures; 3-dimentional Effect factors; Finite element method; Strength; Moment;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Canadian Standards Association, CAN/CSA - S6 - 00 (2001): Canadian Highway Bridge Design Code, Rexdale, Ontario.
2 Duncan, J. M. (1979), "Behaviour and Design of Long-Span Metal Culvert Structures", ASCE Journal of Geotechnical Division, Vol.105, No.3, pp.399-417.
3 포항산업과학연구원 (1998), 파형강판 지중암거의 설계와 시공, pp.69-74.
4 포항산업과학연구원 (2002), 장스팬 파형강판 구조물 실용화 연구, pp.30-42.
5 윤희두 (2003), "콘크리트 충전 파형강판 구조물의 시공단계별 단면력 평가", 석사학위논문, 한양대학교 대학원 토목공학과, pp.30-52.
6 Byrne, P. M., Anderson, D. L., and Jinto, H. (1996), Seismic Anlysis of Large Buried Culvert Structures Transp. Res. Rec., 1541, pp. 133-139.   DOI
7 건설교통부 (2003), 도로공사 표준시방서, pp.154-178.
8 김성곤 (2003), "대골형 파형강판 휨강도에 대한 연구", 석사학위논문, 서울산업대학교 산업대학원 구조공학과, pp.31-45
9 유호연 (2001), "장스팬 파형강판 구조물의 설계법 개발", 석사학위논문, 한양대학교 대학원 토목공학과, pp.26-43.