• Title/Summary/Keyword: Plastic adhesion

Search Result 212, Processing Time 0.027 seconds

Review on Electroless Plating(I) (무전해도금(I))

  • Kim, Man;Kwon, Sik-Chol
    • Journal of the Korean institute of surface engineering
    • /
    • v.19 no.3
    • /
    • pp.121-127
    • /
    • 1986
  • There are many plating methods already commercially employed in te surface technology. One of the plating methods is electroless (chemical) plating, which is deposited by auto-catalytic reduction of metallic ion with the reducing agent in the plating bath. And it has many advantages comparing with electrolytic plating in respect of properties of deposit, such as corrosion resistance, wear resistance, uniformity, hardness, adhesion and so on. So, electroless plating is the fatest growing process in metallization of plastic and electronic industry. The properties and numerous applications of electroless deposits are attracting more and more attention from finish specifies. Many metal finishers are considering set-up of new electroless line in their shops. This review will be beneficial to domestic metal finishers to understand the real status of present electroless plating technology. It will also provide some knowledge on the economic aspect of electroless plating for the commercial application of specific parts.

  • PDF

A Study on the Crack Characteristics of the Syntetic Fiber Reinforced Soil (섬유 보강토의 균열 특성 연구)

  • 송창섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.3
    • /
    • pp.59-65
    • /
    • 1999
  • This study has been performed to confirm the three dimensional effect of the crack reduction and the restrained effect of crack growth for the synthetic fiber reinforced soil. Two types of polyrpropylene fiber and low plastic clay(CL) were used for the test. And the test variable were fiber length and so on. The results of the study were summarized as follows ; 1) The mixing of synthetic fiber was effective in reducing crack growth due to adhesion between soil partlcles and synthetic fiber.l Especially initlal crack was delayed, as compared with the pure soil, for about 1 day in case of mono filament synthetic fiber and for about 1 or 2 days in case of fibrillated syntetic fiber. 2) As the content and length of synthetic fiber were increased , the effect of crack reduction was increased. It was found that 0.5% fibrillated synthetic fiber with 40mm length reinforced soil had about 3 times more effective than natural soils. 3) In case of the same fiber content and fiber length, the fibrillated synthetic fiber has nmore effective than the mono filament synthetic fiber for crack reduction.

  • PDF

Study about cracking reducing of the concrete by utilizing fiber-reinforced admixture (섬유보강재 혼입비율 및 길이에 따른 콘크리트 균열제어에 관한 연구)

  • Kim, Dae-Geon;Choi, Sang-Hwan;Moon, Gyeong-Sik;Jo, Man-Ki;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.144-145
    • /
    • 2014
  • Nowadays, as to increased the workability of the press concrete and decrease the cracking, the fiber-reinforced admixture has been widely used. As the low adhesion force between the paste and fiber-reinforced admixture, it was considered as could not be used in the structure. Even more, as the loss of flowability and the exposure of the fiber, further study is needed. In this study, as the different environment and position of the building, the dosages of the fiber-reinforced admixture has also been changed. The fundamental properties and cracking of fiber-reinforced concrete have been tested.

  • PDF

Acceleration of Integra Incorporation in Reconstruction of Burn Scar Contracture with The Vacuum-Assisted Closure(VAC) (Integra®를 이용한 화상 반흔 구축 재건에 있어 Vacuum-Assisted Closure(VAC)의 유용성)

  • Oh, Suk Joon;Jeon, Man Kyung;Ko, Sung Hoon
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.432-436
    • /
    • 2009
  • Purpose: Negative pressure therapy has been used in various conditions to promote wound healing. It has also been used to secure a skin graft by improving microcirculation and improving tight adhesion between the graft and the recipient bed. To reduce post burn scar contracture and improve aesthetical result, many types of dermal substitutes have been invented and used widely. The goal of this study was evaluate usefulness of the VAC (Kinetic concepts Inc., San Antonio, TX) in improving the take rate and time to incorporation of Integra$^{(R)}$ in reconstruction of burn scar contracture. Methods: A retrospective study was performed from October, 2006 to December, 2008. The VAC was utilized for 11 patients. The average patient's age was 19.7 years (range 5 - 27) and average surface area was $785cm^2$ (range 24 - 1600). The burn scars were excised deep into normal subcutaneous tissue to achieve complete release of the scar, Integra$^{(R)}$ was sutured in place with skin staple와 Steri - strip$^{(R)}$. Then slit incisions were made on silicone sheet only with No.11 blade for effective drainage. The VAC was used as a bolster dressing over Integra$^{(R)}$. Negative - Pressure ranging from 100 to 125 mm Hg was applied to black polyurethane foam sponge trimmed to the appropriate wound size. An occlusive seal over the black polyurethane foam sponge was maintained by a combination of the occlusive dressing, OP - site$^{(R)}$. The VAC dressing changes were performed every 3 or 4 days until adequate incorporation was obtained. The neodermis appeared slightly yellow to orange color. When the Integra$^{(R)}$ deemed clinically incorporated, The VAC was removed and take was estimated with visual inspection. Very thin STSG(0.006 ~ 0.008 inches) was performed after silicone sheet removal. Result: The mean time for clinically assessed incorporation of Integra$^{(R)}$ was 10.00 days (range 9 - 12). The mean dressing change was 3.5 times until take was obtained. In All patients, Integra$^{(R)}$ had successful incorporation in tissue without serious complications. Conclusion: Integra$^{(R)}$ in combination with Vacuum - Assisted Closure(VAC) may be incorporated earlier than conventional dressing method.

Preparation of Hard Coating Solutions using Colloidal Silica and Glycidoxypropyl Trimethoxysilane by the Sol-Gel Method (Sol-Gel 법에 의해 Colloidal Silica와 Glycidoxypropyl Trimethoxysilane으로 부터 하드코팅 용액의 제조)

  • Kim, Dae Hyun;Song, Ki Chang;Chung, Jae Shik;Lee, Bum Suk
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.442-447
    • /
    • 2007
  • In order to improve the surface hardness of transparent plastic films, organic-inorganic hybrid coating solutions were synthesized by the sol-gel method. The coating solutions were prepared by adding GPTMS (glycidoxypropyl trimethoxysilane) to a colloidal silica (12 nm) suspension. PC(polycarbonate) substrates were dipped into the coating solutions and dried at room temperature for 10 min before being cured at $80^{\circ}C$ for 30 min. The effect of the solution pH and GPTMS content was investigated on the properties of coating films. The pencil hardness and adhesion to substrates of the coating films, prepared at acidic condition (pH 4), showed better properties than those at neutral or basic conditions. Also, the pencil hardness and adhesion to substrates of the coating films increased with increasing GPTMS content.

A Comparative Study on Test Methods for Ophthalmic Lens Coatings (안경렌즈 코팅의 평가 방법에 관한 비교 연구)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Ha, Jin-Wook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2006
  • We have surveyed test methods for ophthalmic lens coatings and compared the coating quality of lenses supplied by manufactures. Plastic ophthalmic lenses are produced in increasingly larger volumes. However, their softness have need resistant coatings absolutely essential in most cases. Coating lenses are typically evaluated in physical and chemical properties through random selection from produced lenses. No international standard test methods for ophthalmic lenses exist for issues such as adhesion, abrasion resistance, hardness, chemical and hot water resistance with exception of transmittance. We have learned that there is a great deal of confusion regarding the methods employed in the various tests for ophthalmic coating lenses. For this reason, test methods for ophthalmic lens coatings are needed making all of international or domestic standards available.

  • PDF

Analysis of the Load Carrying Behavior of Shear Connection at the Interface of Encased Composite Beams (매입형 합성보의 전단합성거동에 대한 비교분석)

  • Shin, Hyun Seop;Heo, Byung Wook;Bae, Kyu Woong;Kim, Keung Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.67-79
    • /
    • 2008
  • In this study, a bending test with three encased composite beams were carried out and analyzed using FEM in order to find how chemical adhesion, interface interlock, friction and composite action by shear studs contribute to stiffness, strength and composite action in the interface of encased compo site beams. The test and results of the FEM analysis showed that the difference in the ultimate moment capacity of the composite beams with and without studs is under 10%. The reason is that the effect of chemical adhesion, interface interlock, and friction in the interface on the composite action is so high that the encased beams have a moment capacity above some defined magnitude. Also, the increment of moment capacity up to plastic moment is not large and the increase of linearly proportioned.

Adhesive Performance and Fracture Toughness Evaluation of FRP-Reinforced Laminated Plate (FRP 보강적층판의 접착성능 및 파괴인성평가)

  • Jung, Hong-Ju;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.868-875
    • /
    • 2015
  • In order to replace existing slit type steel plate on the wooden structure joint, the FRP-reinforced laminated plates were produced. Four types of FRP-reinforced laminated plates were produced according to the type of reinforcement and adhesive, and before applying to the joint, the adhesion performance test according to KSF 3021 and KSF 2160 and the Compact Tension (CT) type fracture toughness test specified in ASTM D5045-99 were carried out. As a result of adhesion performance test, all GFRP textile, GFRP sheet, and GFRP Textile-Sheet type FRP-reinforced laminated plates satisfied the requirement of soaking delamination percentage with smaller than 5% based on KS standard. However, aramid type specimen satisfied the standard as the soaking delamination percentage of 4.8% but it did not satisfied the standard as the water proof soaking delamination percentage of 70%. As a result of fracture toughness test, the volume ratio of reinforcement to timber became 23% so that the strength of FRP-reinforced laminated plates increased by two to four times in comparison to the control specimen. It was confirmed that the GFRP Textile-Sheet type specimen was most resistant to the fracture most since the ratio of stress intensity factor compared with that of the control increased to 61% owing to the parallel arrangement of glass fiber to the load. As a result of tensile shear strength test using FRP-reinforced laminated plates and nonmetal dowels, it is about 12% lower than metal connectors.

Surface Modification of Recycled Plastic Film-Based Aggregates for Use in Concrete (폐플라스틱 복합필름 기반 콘크리트용 골재의 표면 개질)

  • Kim, Tae Hun;Lee, Jea Uk;Hong, Jin-Yong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.295-302
    • /
    • 2021
  • Surface modification of recycled plastic film-based aggregates is demonstrated to enhance the interaction between aggregates and cement paste. It is shown that the oxygen(O2) atmospheric pressure plasma(APP) treatment leads to a drastic increase in hydrophilicity. In case of the plasma treatment at 100W of RF power, 15/4sccm of O2/Ar flow rate and 30sec of discharging time, the water contact angle on the aggregates surface decreased from 104.5° to 44.0°. In addition, the contact angle of surface modified aggregates kept in air increased with time elapse. Improvement of hydrophilicity can be explained by the formation of new hydrophilic oxygen functional groups which is identified as C-OH, C-O-C, C=O, -COOH by X-ray photoelectron spectroscopy(XPS) analysis and Fourier-transform infrared spectroscopy(FT-IR). Therefore, it can be concluded that the plasma treatment process is an effective method to improve adhesion of the recycled plastic film-based aggregates and cement paste.

Reinforcement, Thermal and Fire Retardant Improvement of Phenolic Composites by Surface Treatment of CFRP Chip (CFRP Chip 표면처리에 따른 페놀복합재료의 강화, 내열성 및 난연성 향상)

  • Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.13 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • CFRP chip is the byproduct from carbon fiber reinforced plastic (CFRP) processing. CFRP chip is not simply a waste mainly composed of fine carbon fiber and epoxy resin. CFRP chip keeps matrix to maximize their reinforcing effect. To obtain a uniform length of carbon fiber in CFRP chip, chip was chopped ina mortar. CFRP chip should be purified to get better interface adhesion. Epoxy resin on the carbon fiber was removed by $H_2O_2$ surface etching treatment. Optimal dispersion and fabrication conditions of CFRP chip embedded in phenolic resin were determined by thermal stability for fire retardant applications. CFRP chip-phenolic composite exhibits better mechanical and thermal properties than neat phenolic resin. Surface condition of CFRP chip-phenolic composite was evaluated by static contact angle measurement. Contact angle of CFRP chip-phenolic composite was greater than neat phenolic due to heterogeneous condition of fine carbon fibers. From the evaluation for fire retardant (ASTM D635-06) test, thermal stability of CFRP chip-phenolic composite was found to be improved with higher concentration of CFRP chip.