• 제목/요약/키워드: Plasma-Solution System

검색결과 122건 처리시간 0.028초

Si and Mg doped Hydroxyapatite Film Formation by Plasma Electrolytic Oxidation

  • Park, Seon-Yeong;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.195-195
    • /
    • 2016
  • Titanium and its alloys are widely used as implants in orthopedics, dentistry and cardiology due to their outstanding properties, such as high strength, high level of hemocompatibility and enhanced biocompatibility. Hence, recent works showed that the synthesis of new Ti-based alloys for implant application involves more biocompatible metallic alloying element, such as, Nb, Hf, Zr and Mo. In particular, Nb and Hf are one of the most effective Ti ${\beta}-stabilizer$ and reducing the elastic modulus. Plasma electrolyte oxidation (PEO) is known as excellent method in the biocompatibility of biomaterial due to quickly coating time and controlled coating condition. The anodized oxide layer and diameter modulation of Ti alloys can be obtained function of improvement of cell adhesion. Silicon (Si) and magnesium (Mg) has a beneficial effect on bone. Si in particular has been found to be essential for normal bone and cartilage growth and development. In vitro studies have shown that Mg plays very important roles in essential for normal growth and metabolism of skeletal tissue in vertebrates and can be detected as minor constituents in teeth and bone. The aim of this study is to research Si and Mg doped hydroxyapatite film formation by plasma electrolytic oxidation. Ti-29Nb-xHf (x= 0, 3, 7 and 15wt%, mass fraction) alloys were prepared Ti-29Nb-xHf alloys of containing Hf up from 0 wt% to 15 wt% were melted by using a vacuum furnace. Ti-29Nb-xHf alloys were homogenized for 2 hr at $1050^{\circ}C$. Each alloy was anodized in solution containing typically 0.15 M calcium acetate monohydrate + 0.02 M calcium glycerophosphate at room temperature. A direct current power source was used for the process of anodization. Anodized alloys was prepared using 270V~300V anodization voltage at room. A Si and Mg coating was produced by RF-magnetron sputtering system. RF power of 100W was applied to the target for 1h at room temperature. The microstructure, phase and composition of Si and Mg coated oxide surface of Ti-29Nb-xHf alloys were examined by FE-SEM, EDS, and XRD.

  • PDF

Spark plasma sintering of UO2 fuel composite with Gd2O3 integral fuel burnable absorber

  • Papynov, E.K.;Shichalin, O.O.;Belov, A.A.;Portnyagin, A.S.;Buravlev, I.Yu;Mayorov, V.Yu;Sukhorada, A.E.;Gridasova, E.A.;Nomerovskiy, A.D.;Glavinskaya, V.O.;Tananaev, I.G.;Sergienko, V.I.
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1756-1763
    • /
    • 2020
  • The paper studies spark plasma sintering (SPS) of industrially used UO2-based fuel containing integral fuel burnable absorber (IFBA) of neutrons Gd2O3. Densification dynamics of pristine UO2 powder and the one added with 2 and 8 wt% of Gd2O3 under ultrasonication in liquid has been studied under SPS conditions at 1050, 1250, and 1450 ℃. Effect of sintering temperature on phase composition as well as on O/U stoichiometry has been investigated for UO2 SPS ceramics. Sintering of uranium dioxide added with Gd2O3 yields solid solution (U,Gd)O2, which is isostructural to UO2. SEM with EDX and metallography were implemented to analyze the microstructure of the obtained UO2 ceramics and composite UO2-Gd2O3 one, particularly, open porosity, defects, and Gd2O3 distribution were studied. Microhardness, compressive strength and density were shown to reduce after addition of Gd2O3. Obtained results prove the hypothesis on formation of stable pores in the system of UO2-Gd2O3 due to Kirkendall effect that reduces sintering efficiency. The paper expands fundamental knowledge on pros and cons of fuel fabrication with IFBA using SPS technology.

다검출기 유도결합 플라즈마 질량분석기를 이용한 경주 입실, 장항리 단층 파쇄대 충진 탄산염암 맥의 $^{230}Th/^{234}U$ 비평형 연대측정 ($^{230}$ Th/$^{234}$ U disequilibrium dating of fracture-filling carbonate veins from the Ipsil and Janghangri fault zones, Gyeongju, Korea by multiple collector inductively coupled plasma mass spectrometry)

  • 정창식;최만식;김현철;임상복
    • 암석학회지
    • /
    • 제10권3호
    • /
    • pp.148-156
    • /
    • 2001
  • 경북 경주시 인근의 제4기 추정단층 중 입실단층과 장항리단층의 파쇄대를 충진하고 있는 탄산염암맥을 대상으로 다검출기 유도결합 플라즈마 질량분석기를 이용한 $^{230}$ $Th^{234}$ U 비평형 연대를 측정하였다. 완전히 녹인 시료로부터 공침과 이온교환화학을 통해 간편하게 U, Th을 단체분리하였는데 회수율은 Th 80%, U 70% 정도였다. 이 부분으로부터 기기 조건이 최적화된 다검출기 유도결합 플라즈마 질량분석기를 이용하여 $^{234}$ $U^{238}$ $U^{230}$ $Th^{232}$ Th비를 분석하였고 U/Th비는 처리하지 않은 시료로부터 직접 분석하였다. 분석 결과 입실 단층의 탄산염암 맥은 $^{234}$ U-$^{230}$ Th 시차평형에 도달하여 기존의 ESR 연대측정 결과를 지지하였으며 쇄설성 부분이 보정된 장항리단층 탄산염암 맥의 $^{230}$$Th^{234}$ /U 비평형 연대는$ 48\pm$41 ka로서 파쇄대의 최소 형성시기를 지시한다.

  • PDF

WETTABILITY AND DRUG DELIVERY OF FUNCTIONALLY GRADED NANO-MICRO POROUS TITANIUM SURFACE

  • Yun, Kwi-Dug;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.307-319
    • /
    • 2008
  • STATEMENT OF PROBLEM: It is known that an anodic oxidation technique, one of the methods for the implant surface treatment, remarkably increased surface area, enhanced wettability and accelerated the initial bone healing. Purpose: This study was performed to evaluate the wettability of anodized titanium surface which has a nanotubular structure, to assess osseointegration after the placement of implant with nano-size tubes on tibia of rats and to analyze quantitatively transferable rhBMP-2 on each surface. MATERIAL AND METHOD: Four different kinds of surface-treated titanium discs (polished (machined surface) group, micro (blasting surface) group, nano (anodizedmachined surface) group, and nano-micro (anodized-blasting surface) group) were fabricated (n=10). Three different media were chosen to measure the surface contact angles; distilled water, plasma and rhBMP-2 solution. After a single drop (0.025 $m{\ell}$) of solution, the picture was taken with the image camera, and contact angle was measured by using image analysis system. For the test of osseointegration, 2 kinds of anodized surface (anodized-machined surface, anodized-blasting surface) implants having 2.0 mm in diameter and 5.0 mm in length inserted into the tibia of Wistar rats. After 3 weeks, tibia were harvested and the specimens were stained with hematoxylin and eosin for histological analysis. To test the possibility of drug delivery, after soaking sample groups in the concentration of 250 ng/$m{\ell}$l of rhBMP-2 for 48 hours, the excess solution of rhBMP-2 were removed. After that, they were lyophilized for 24 hours, and then the rhBMP-2 on the surface of titanium was resolved for 72 hours in PBS. All the extracted solution was analyzed by ELISA. One-way analysis of variance (ANOVA) was performed on the data. RESULTS: The wettability is improved by anodic oxidation. The best wettability was shown on the nano-micro group, and it was followed by nano group, micro group, and polished group. In the histological findings, all implants showed good healing and the new bone formation were observed along the implant surface. After 3 days, nano-micro group delivered the most amount of rhBMP-2, followed by nano group, micro group, and polished group. CONCLUSION: It indicated that anodic oxidation on blasting surface produce functionally graded nano-micro porous structure and enhance hydrophilicity of the surface and osseointegration. The findings suggest that the nano-micro porous structure could be a useful carrier of osteogenic molecules like rhBMP-2.

SB-31의 Glycyrrhizin을 지표로 한 Rat과 Rabbit에서의 약물동태 및 심혈관계에 대한 효과 연구 (Pharmacokinetics of Anticancer Agent SB-31 in Rats & Rabbits and the Cardiovascular Effect on the Isolated Perfused Rat Heart & Blood Coagulation)

  • 강원구;박용순;이동흠;권광일
    • 한국임상약학회지
    • /
    • 제8권2호
    • /
    • pp.122-132
    • /
    • 1998
  • SB-31 which contains Pursatilla, Licoris and Ginseng extracts was recently proved as an anticancer agent. In a preclinical effort to be applied this drug to human, pharmacokinetics of SB-31 was carried out in rats and rabbits. Glycyrrhizin(GZ), a saponin of Licoris was used as a standard ingradient for the pharmacokinetics of SB-31. The rat's blood, bile and urine samples were serially collected in femoral vein, common bile duct and bladder, respectively, after bolus i.v. injection at a dose of 1 or 1/5 ampul/rat and rabbit's blood samples from the marginal ear vein at a dose of 1 or 3 amp./rabbit. GZ and glycyrrhetic acid(GA), a major metabolite of GZ in the physiological samples were analysed by HPLC with UV detection. The decline of GZ in plasma concentration was generally biexponential at each dose. GZ was almost completely recovered in bile within 18 hour. GA wasn't detected in the samples with UV detector. In the rat, Vss and Kel at a dose of 1 and 1/5 ampul of SB-31 were $98.06\pm6.07\;ml,\;0.33\pm0.05\;hr^{-1}\;and\;65.46\pm11.19\;ml,\;0.68\pm0.25\;hr^{-1}$, respectively. Those in rabbits at a dose of 3 and 1 ampul of SB-31 were $235.24\pm30.72\;ml,\;0.13\pm0.36\;hr^{-1}\;and\;341.32\pm28.58\;ml,\;0.27\pm0.04\;hr^{-1}$, respectively. 'WinNonlin' was utilized for the compartmental analysis. A two-compartment model was chosen as the most appropriate pbarmaco-kinetic model. The data were best described by using a weighting factor of $1/y^2$. To evaluate the effect of SB-31 on cardiovascular system, serially diluted SB-31 was directly injected into coronary artery in the isolated perfused rat heart and the effect of PSF, PSH, saponins of Pursatilla, and SB-31 on PT, APTT of healthy human plasma was examined. Except the positive inotropic effect of ten times diluted solution of SB-31, there was no significant effect on LVDP, (- dp/dt)/(+dp/dt), heart rate and coronary flow in comparision with that of vehicle. SB-31 had no effect on PT but slightly delayed APTT about $6.9{\sim}11.5\%$. There was no significant effect of PSF and PSH on PT & APTT. Conclusively, SB-31 did not show any notable toxic effects on cardiovascular system.

  • PDF

Bile Acid Inhibition of N-type Calcium Channel Currents from Sympathetic Ganglion Neurons

  • Lee, Hye-Kyung;Lee, Kyoung-Hwa;Cho, Eui-Sic
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제16권1호
    • /
    • pp.25-30
    • /
    • 2012
  • Under some pathological conditions as bile flow obstruction or liver diseases with the enterohepatic circulation being disrupted, regurgitation of bile acids into the systemic circulation occurs and the plasma level of bile acids increases. Bile acids in circulation may affect the nervous system. We examined this possibility by studying the effects of bile acids on gating of neuronal (N)-type $Ca^{2+}$ channel that is essential for neurotransmitter release at synapses of the peripheral and central nervous system. N-type $Ca^{2+}$ channel currents were recorded from bullfrog sympathetic neuron under a cell-attached mode using 100 mM $Ba^{2+}$ as a charge carrier. Cholic acid (CA, $10^{-6}M$) that is relatively hydrophilic thus less cytotoxic was included in the pipette solution. CA suppressed the open probability of N-type $Ca^{2+}$ channel, which appeared to be due to an increase in (no activity) sweeps. For example, the proportion of sweep in the presence of CA was ~40% at +40 mV as compared with ~8% in the control recorded without CA. Other single channel properties including slope conductance, single channel current amplitude, open and shut times were not significantly affected by CA being present. The results suggest that CA could modulate N-type $Ca^{2+}$ channel gating at a concentration as low as $10^{-6}M$. Bile acids have been shown to activate nonselective cation conductance and depolarize the cell membrane. Under pathological conditions with increased circulating bile acids, CA suppression of N-type $Ca^{2+}$ channel function may be beneficial against overexcitation of the synapses.

Fabrication of Large Area Transmission Electro-Absorption Modulator with High Uniformity Backside Etching

  • Lee, Soo Kyung;Na, Byung Hoon;Choi, Hee Ju;Ju, Gun Wu;Jeon, Jin Myeong;Cho, Yong Chul;Park, Yong Hwa;Park, Chang Young;Lee, Yong Tak
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.220-220
    • /
    • 2013
  • Surface-normal transmission electro-absorption modulator (EAM) are attractive for high-definition (HD) three-dimensional (3D) imaging application due to its features such as small system volume and simple epitaxial structure [1,2]. However, EAM in order to be used for HD 3D imaging system requires uniform modulation performance over large area. To achieve highly uniform modulation performance of EAM at the operating wavelength of 850 nm, it is extremely important to remove the GaAs substrate over large area since GaAs material has high absorption coefficient below 870 nm which corresponds to band-edge energy of GaAs (1.424 eV). In this study, we propose and experimentally demonstrate a transmission EAM in which highly selective backside etching methods which include lapping, dry etching and wet etching is carried out to remove the GaAs substrate for achieving highly uniform modulation performance. First, lapping process on GaAs substrate was carried out for different lapping speeds (5 rpm, 7 rpm, 10 rpm) and the thickness was measured over different areas of surface. For a lapping speed of 5 rpm, a highly uniform surface over a large area ($2{\times}1\;mm^2$) was obtained. Second, optimization of inductive coupled plasma-reactive ion etching (ICP-RIE) was carried out to achieve anisotropy and high etch rate. The dry etching carried out using a gas mixture of SiCl4 and Ar, each having a flow rate of 10 sccm and 40 sccm, respectively with an RF power of 50 W, ICP power of 400 W and chamber pressure of 2 mTorr was the optimum etching condition. Last, the rest of GaAs substrate was successfully removed by highly selective backside wet etching with pH adjusted solution of citric acid and hydrogen peroxide. Citric acid/hydrogen peroxide etching solution having a volume ratio of 5:1 was the best etching condition which provides not only high selectivity of 235:1 between GaAs and AlAs but also good etching profile [3]. The fabricated transmission EAM array have an amplitude modulation of more than 50% at the bias voltage of -9 V and maintains high uniformity of >90% over large area ($2{\times}1\;mm^2$). These results show that the fabricated transmission EAM with substrate removed is an excellent candidate to be used as an optical shutter for HD 3D imaging application.

  • PDF

Development of liquid target for beam-target neutron source & two-channel prototype ITER vacuum ultraviolet spectrometer

  • Ahn, B.N.;Lee, Y.M.;Dang, J.J.;Hwang, Y.S.;Seon, C.R.;Lee, H.G.;Biel, W.;Barnsley, R.;Kim, D.E.;Kim, J.G.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.421-422
    • /
    • 2011
  • The first part is about development of a liquid target for a neutron source, which is designed to overcome many of the limitations of traditional beam-target neutron generators by utilizing a liquid target neutron source. One of the most critical aspects of the beam-target neutron generator is the target integrity under the beam exposure. A liquid target can be a good solution to overcome damage to the target such as target erosion and depletion of hydrogen isotopes in the active layer, especially for the one operating at high neutron fluxes with no need for water cooling. There is no inherent target lifetime for the liquid target neutron generator when used with continuous refreshment of the target surface exposed to the energetic beam. In this work, liquid target containing hydrogen has been developed and tested in vacuum environment. Potentially, liquid targets could allow a point neutron source whose spatial extension is on the order of 1 to $10{\mu}m$. And the second is about the vacuum ultraviolet (VUV) spectrometer which is designed as a five-channel spectral system for ITER main plasma measurement. To develop and verify the design, a two-channel prototype system was fabricated with No. 3 (14.4 nm~31.8 nm) and No. 4 (29.0 nm~60.0 nm) among the five channels. For test of the prototype system, a hollow cathode lamp is used as a light source. The system is composed of a collimating mirror to collect the light from source to slit, and two holographic diffraction gratings with toroidal geometry to diffract and also to collimate the light from the common slit to detectors. The two gratings are positioned at different optical distances and heights as designed. To study the appropriate detector for ITER VUV system, two different electronic detectors of the back-illuminated charge coupled device and the micro-channel plate electron multiplier were installed and the performance has been investigated and compared in the same experimental conditions. The overall system performance was verified by measuring the spectrums.

  • PDF

수종의 광중합기에 의한 복합레진 중합시 미세누출에 관한 연구 (MICROLEAKAGE IN RESIN COMPOSITE POLYMERIZED WITH VARIOUS LIGHT CURING UNITS)

  • 박성진;김대업;이광희
    • 대한소아치과학회지
    • /
    • 제32권4호
    • /
    • pp.604-610
    • /
    • 2005
  • 현재 광중합 복합레진은 치아의 수복을 위하여 많이 사용되며 복합레진이 많이 사용되는 만큼 광중합을 위한 광중합기도 다양하게 사용된다. 하지만 광중합기에 따른 복합레진의 미세누출은 아직 연구대상이다. 본 연구의 목적은 광중합기에 따라 발생하는 미세누출에 대한 평가를 하는 것으로 최근에 개발된 광중합기의 중합능력을 전통적 인 할로겐 광중합기와 비교하는 것이다. 전통적으로 사용되어지던 저출력 할로겐 광중합기(Optilux 360), 일반 플라즈마 아크 광중합기(Flipo). 저발열 플라즈마 아크 광중합기 (Aurys), 고출력 LED 광중합기 (Freelight 2)를 사용하였다. 건전한 유구치에 와동을 형성한 후 복합레진(Z100)을 동일한 레진 접착제 (Scotchbond Multi-Purpose)를 사용하여 충전한 후 각 광중합기를 이용하여 복합레진을 중합시켰다. 광중합기의 광조사 시간은 제조사에서 복합레진의 광중합을 위해 권장하는 시간으로 Optilux 360은 40초, Flipo는 5초, Aurys는 9초, Freelight 2는 20초간 조사하였다. Optilux 360만 광강도의 변화가 없는 광조사 방식이며 그 외 광중합기들은 광강도가 광조사 중에 증가되는 soft-start 광조사 방식이다. 각 시편을 증류수에 24시간 보관 후 열 순환을 1000회 시행한 후 2% methylene blue용액으로 색소침투를 시켰으며 각 시편을 절단하여 색소침투 정도를 점수화시켜 다음과 같은 결론을 얻었다. 미세누출을 각 점수화하였을 때 Aurys가 평균 0.95로 가장 낮은 값을 보였고 Freelight 2(1.05), Flipo(1.25), Optilux 360(1.30)의 순이었다. 하지만 각 광중합기군 간의 값에서는 통계학적인 유의성은 관찰되지 않았다(P>0.05).

  • PDF

레이저 유도 충격파를 이용한 첨단 약물전달시스템 개발 (New Drug Delivery System Based on a Laser-Induced Shockwave)

  • 한태희;이현희;;여재익
    • 대한기계학회논문집B
    • /
    • 제34권1호
    • /
    • pp.67-71
    • /
    • 2010
  • 1 GW/$cm^2$ 이상의 고강도의 레이저 빔을 얇은 금속 호일의 한 점에 집중시키면, 레이저 삭마현상에 의해 발생된 충격파가 금속 호일 안으로 전파하게 된다. 이 충격파는 금속 호일의 반대 면에서 팽창파로 반사되고, 그 과정에서 금속 호일에 급격한 변형이 일어난다. 이 때, 금속 호일의 반대 면에 미세한 마이크로 단위 크기의 입자들을 코팅하면, 금속의 순간적인 변형으로 인해 입자들이 큰 운동량을 얻으며 가속되어 빠른 속도로 튕겨져 나가게 되는데 이것이 바이오리스틱 약물 전달의 원리이다. 이번 연구에서는 바이오리스틱 시스템의 제어성, 안정성, 효율을 향상시키고자 컨파인 조건을 변화시키며, 인체의 연한 조직을 모사하는 3% 젤라틴 용액으로의 침투 모습을 파악하였다. 사용한 컨파인 매질은 BK7 유리, 물, 그리고 초음파젤(RHAPAPHRM Co. Ltd)이다. 실험결과, 컨파인 매질과 그 두께를 조절함으로써 마이크로 입자들의 침투 양상을 제어할 수 있음을 확인하였다.