• Title/Summary/Keyword: Plan index

Search Result 835, Processing Time 0.028 seconds

제주도 서부지역의 지하수 오염취약성 작성 연구

  • Lee Yong-Du;Song Hui-Gyeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.316-318
    • /
    • 2006
  • The purpose of this research is to write out vulnerability for western area in Jeju island by using drastic method which is the most frequently utilized among the writing techniques of underground water vulnerability. In case of aquifer, it was divided into two types, gravel layer or not and rated. And soil media was rated two kinds of method. Plan 1 is concerned with only soil class and plan 2 is concerned with soil class and gravels (or rocks), Vadose zone was rated differently according to the ratio of gravel layer. In case of plan 1, the scope of drastic index is from the minimum 77 to the maximum 176, on the other hand, plan 2, the scope of drastic index is from the minimum 79 to the maximum 182. In case of using the water quality data of Nitrate from 1994 to 2004, Pearson correlation coefficient are 0.164(Plan 1) and 0.124(Plan 2) and Spearman correlation coefficient are 0.132(Plan 1) and 0.113.

  • PDF

A Study on the Improvement Method of the Local Safety Level Index in Basic Local Governments (기초지방자치단체의 지역안전지수 향상방안 연구)

  • Song, Changyoung
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.211-222
    • /
    • 2020
  • Purpose: The purpose of the Improvement method of Local Safety Level Index in guideline of disaster safety master plan. Method: This research will establish disaster safety management system strategy through consistency analysis of law, safety innovation master plan and international safety cities index regarding disaster safety and proposes guideline of disaster safety master plan which includes that includes regional characteristics and disaster management measures by sector. Result: Establish detailed policies applying the disaster safety master plan guideline to improve the local safety level index in 'G'-basic local government. Conclusion: In this study, basic local government will Strengthen the disaster response capacity by improving the local safety level index.

A Study on the Efficiency Evaluation for the School Facilities - Focused on the architectural planning evaluation - (노후화 학교시설의 개축성능 평가에 관한 연구 - 건축 계획적 평가를 중심으로 -)

  • Kim, Seung-Je
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.12 no.6
    • /
    • pp.56-67
    • /
    • 2005
  • The purpose of this study is to give the detailed evaluation index which is considered by reconstruction and repair for the school facilities on the ground of the efficiency evaluation result in each plan through analyzing the school facilities to every case classified into the evaluation index such as the school site plan, the site plan, the floor plan. On this study through the detailed evaluation index each case to the school facilities is to get the result of the efficiency evaluation. Through analysing the result, to make an alternative plan of the school facilities which are fit in both the new educational process and the educational state is to give it as a guide.

Risk based Value Index Evaluation Model for Modular Design Alternatives in Plant Construction Projects (플랜트 건설사업의 모듈러 설계대안별 RVI 평가 모델)

  • Kang, Hyun Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.5
    • /
    • pp.98-107
    • /
    • 2022
  • The purpose of this study is to suggest a model for evaluation of a risk based value index for modular design alternatives in plant construction projects. Accordingly, 1) Setting the basic project cost and the scope to apply the module, 2) Evaluating the importance, easiness, and effectiveness index for Engineering, Procurement, Fabrication, transportation, and construction work, 3) Estimating the total project cost by analyzing the risk reserve Step, 4) Comparing the effectiveness index and total project cost for each modular design alternative, it was composed of the steps of deriving RVI. To verify such a model, Plan-A, which applied a module to one process, and Plan-B, which applied a module to three processes, were composed to evaluate RVI.

A Study on Prospective Plan Comparison using DVH-index in Tomotherapy Planning (토모 테라피 치료 시 선량 체적 히스토그램 표지자를 이용한 치료계획 비교에 관한 연구)

  • Kim, Joo-Ho;Cho, Jeong-Hee;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Yoon, Jong-Won;Kim, Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.113-122
    • /
    • 2007
  • Purpose: We proposed the method using dose-volume Histogram index to compare prospective plan trials in tomotherapy planning optimization. Materials and Methods: For 3 patients in cranial region, thorax and abdominal region, we acquired computed tomography images with PQ 5000 in each case. Then we delineated target structure and normal organ contour with pinnacle Ver 7.6c, after transferred each data to tomotherapy planning system (hi-art system Ver 2.0), we optimized 3 plan trials in each case that used differ from beam width, pitch, importance. We analyzed 3 plan trials in each region with isodose distribution, dose-volume histogram and dose statistics. Also we verified 3 plan trials with specialized DVH-indexes that is dose homogeneity index in target organ, conformity index around target structure and dose gradient index in non-target structures. Results: We compared with the similarity of results that the one is decide the best plan trial using isodose distribution, dose volume histogram and dose statistics, and the another is using DVH-indexes. They all decided the same plan trial to better result in each case. Conclusion: In some of case, it was appeared a little difference of results that used to DVH-index for comparison of plan trial in tomotherapy by special goal in it. But because DVH-index represented both dose distribution in target structure and high dose risk about normal tissue, it will be reasonable method for comparison of many plan trials before the tomotherapy treatments.

  • PDF

A Improvement Study on the Medical Information Protection Using Personal Information Management System(PIMS) : Focus on medical practitioners (개인정보보호관리체계(PIMS)를 이용한 의료정보보호 개선 방안 연구 : 의료기관 종사자를 중심으로)

  • Min, Kyeongeun;Kim, Sungjun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.3
    • /
    • pp.87-109
    • /
    • 2016
  • This study intends to present an effective and efficient development plan about the information protection of medical institutions, by establishing the improvement plan about Personal Information Management System(PIMS) appropriate to the characteristics of medical information focusing on medical institutions generating and using domestic medical information, and doing an empirical study on medical information protection plan. For this, in view of the medical characteristics of the existing Information Security Management System(ISMS), the study presented a study model appropriated to medical institutions based on Personal Information Management Systems index specialized for personal information, and through this, presented the vulnerability diagnosis and vulnerability improvement plan. Based on ISMS index, it designed an improvement index of personal information protection management about each index. The study conducted a survey for executives and employees about PIMS. Accordingly, it presented vulnerability diagnosis items of the current management system indexes from the viewpoint of the people who establish and mange the personal information protection about patients' medical information targeting executives and employees who serve at hospitals and can access medical information.

Selection of radiation treatment plan technique at breast cancer operating technique (유방암 수술기법에 따른 방사선치료계획 기법의 선택)

  • Kim, Jeong-Ho;Bae, Seok-Hwan;Kim, Ki-Jin;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.125-130
    • /
    • 2015
  • Techniques, using physical wedge filter and using dynamic wedge filter and FIF(Field in Field) and ISCT(Irregular Surface Compensating Technique), have been developed according to progress of radiation therapy of breast cancer. Measurement of dose was done to judge the usefulness of technique using three cases, non tissue loss after breast conserving operating and tissue loss after breast conserving operating and mastectomy. Dose indexes of breast tissue, CI (Conformity Index), HI (Homogeneity Index) and QOC (Quality of Coverage), dose index of skin, or dose indexes of lung, volume of 50 percent dose and 20 percent dose were estimated and compared. Using dynamic wedge filter is useful plan at non tissue loss allowing for high dose of lung. FIF and ISCT are useful plan at tissue loss. ISCT is useful plan at mastectomy. Henceforth, we need to apply to valid plan and body type and thorax size.

Clinical Analysis of Inverse Planning for Radiosurgery ; Gamma Knife Treatment Plan Study (방사선 수술 역방향 치료계획 유용성 평가)

  • Jin, Seong Jin;Je, Jae Yong;Park, Cheol Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.343-348
    • /
    • 2015
  • The purpose of this study is a comparison of forward planning(FP) and inverse planning(IP) of a radiosurgery procedure. 10 patients of acoustic schwannoma MR image were used for treatment plan. FP-1,2 and IP were established under the same condition. FP and IP were compared by number of shot, conformity index(CI), paddic conformity index(PCI), gradiant index(GI) and treatment time. On average the treatment plan produced by IP tool provided an improved or similar CI, PCI, GI and reduced treatment time as compared to the FP (CI;FP-1:0.85, FP-2:0.86, IP:0.94, PCI;FP-1:0.79, FP-2:0.81, IP:0.78, GI;FP-1:2.94, FP-2:2.94, IP:3.01). The inverse planning system provides a clinically useful plan while reducing the planning time and treatment time.

A Study on developing advancement indexes of a urban logistics plan in Incheon Metropolitan City (인천시 도시물류계획 효율적 운영을 위한 개선지표 개발)

  • Chung, Tae-Won
    • Journal of Navigation and Port Research
    • /
    • v.35 no.8
    • /
    • pp.683-689
    • /
    • 2011
  • Urban logistics plan of the previous cargo distribution law has changed into city logistics plan of logistics policy law in which its contents adjusted into direction to improve logistics industries, economic well-being and lifestyle conditions of the city. But the city logistics planning didn't include yet a systematic backbone that plans a vision, performs propelled plan to realize it, and then gives feedback through scientific evaluation indexes. In this context, this paper reviews the previous logistics plans and helps operating and managing a efficient city logistics plan a mid-long term through representative index development required to establish city logistics plan.

Dosimetric Evaluation of an Automatically Converted Radiation Therapy Plan between Radixact Machines

  • Lee, Mi Young;Kang, Dae Gyu;Kim, Jin Sung
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.153-162
    • /
    • 2020
  • Purpose: We aim to evaluate the accuracy and effectiveness of an automatically converted radiation therapy plan between Radixact machines by comparing the original plan with the transferred plan. Methods: The study involved a total of 20 patients for each randomly selected treatment site who received radiation treatment with Radixact. We set up the cheese phantom (Gammex RMI, Middleton, WI, USA) with an Exradin A1SL ion chamber (Standard Imaging, Madison, WI, USA) and GAFCHROMIC EBT3 film (International Specialty Products, Wayne, NJ, USA) inserted. We used three methods to evaluate an automatically converted radiation therapy plan using the features of the Plan transfer. First, we evaluated and compared Planning target volume (PTV) coverage (homogeneity index, HI; conformity index, CI) and organs at risk (OAR) dose statistics. Second, we compared the absolute dose using an ion chamber. Lastly, we analyzed gamma passing rates using film. Results: Our results showed that the difference in PTV coverage was 1.72% in HI and 0.17% in CI, and majority of the difference in OAR was within 1% across all sites. The difference (%) in absolute dose values was averaging 0.74%. In addition, the gamma passing rate was 99.64% for 3%/3 mm and 97.08% for 2%/2 mm. Conclusions: The Plan transfer function can be reliably used in appropriate situations.