• 제목/요약/키워드: Pitting Resistance

검색결과 212건 처리시간 0.029초

오스테나이트 스테인리스강 용접부의 응력부식 거동에 미치는 용접 방법의 영향 (The effect of welding methods on the stress corrosion behavior of the welded austenitic stainless steel)

  • 백신영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.42-50
    • /
    • 1995
  • To study the effect of welding methods on the Stress Corrosion Cracking (SCC) behavior of welded AISI type 316L and 304 austenitic stainless steel, the Slow Strain Rate Technique(SSRT) has been adopted in the boiling 45 wt% $MgCl_2$ solution. The results are as follows. 1) Welded sections are more susceptible than base metal in SCC, and the rank of SCC, and the rasistance in welding method is TIG, MIG, $CO_2$ and ARC. 2) The Ultimate tensile strength(UTS) and the strain of both base metal and welded joint are reduced as decreasing extension rate. 3) The SCC resistance of 316L base metal and welded sections are superior than that of 304. 4) The tendency of pitting and the SCC suseptibility are agreed well, and the SCC site is welded deposit section in 316L whereas HAZ in 304.

  • PDF

Galvanic Corrosion of AZ31 Mg Alloy Contacting with Copper

  • Phuong, Nguyen Van;Moon, Sungmo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.151.1-151.1
    • /
    • 2017
  • This work studied the corrosion behavior of AZ31 Mg alloy galvanically coupled with Cu during immersion in 0.1 and 0.5 M NaCl solutions by in-situ observation and galvanic corrosion current measurement using a zero resistance ammeter. The corrosion behavior of AZ31 Mg alloy was also studied by salt spray test. The average galvanic corrosion density during 2 h immersion in 0.1 NaCl solution was found to decrease as an exponential function with increasing the surface area ratios between AZ31:Cu or with increasing the distance between AZ31 and Cu. The corrosion of electrodeposited Cu on AZ31 Mg alloy was concentrated at the area next to Cu (about 5 mm for immersion test and 2 mm for salt spray test) and pitting corrosion was accelerated at the area beyond the severely corroded area by the galvanic coupling effect.

  • PDF

AGMA 규격에 의한 기어 해석용 S/W 개발에 관한 연구 (A Study on Gear S/W Development Based on AGMA Specifications)

  • 신중호;권순만;황정건;김종찬;김창현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.391-392
    • /
    • 2006
  • Gears are essential and useful elements which power is transmitted from a source to a driven equipment. Therefore, it is very important to design gears correctly. Two important points in the gear design procedures are capacities of the gears's bending strength and pitting resistance. This paper deals with two subjects about spur and helical gears : analyzing for strength and wear capacities, and design of face width. Also, this paper proposes the analytical program which is developed for computer aided design and analysis This program is based on the American Gear Manufactures Association(AGMA) Standards.

  • PDF

Precursor Events in Environmentally Assisted Cracking Behaviour of Light Metals

  • Raja, V.S.
    • Corrosion Science and Technology
    • /
    • 제15권4호
    • /
    • pp.153-158
    • /
    • 2016
  • Light metal alloys of Mg, Ti, and Al undergo environmentally assisted cracking (EAC). Passive film breakdown and pitting are not only precursor events for stress corrosion, but can accelerate hydrogen evolution that is responsible for hydrogen embrittlement. This is clearly demonstrated in the case of Mg and Ti alloys. The so-called innocuous precipitates, which do not directly participate in either alloy strengthening or EAC can be effective precursors for initiating EAC. This aspect is highlighted using high strength aluminium alloys. Such behaviours lead to a paradigm shift in the design of alloys with resistance to EAC.

탄화규소/7091알루미늄 복합재료의 부식거동 (Corrosion Behavior of Silicon Carbide/7091 Aluminum Matrix Composites)

  • 강우승
    • Corrosion Science and Technology
    • /
    • 제11권4호
    • /
    • pp.108-111
    • /
    • 2012
  • The effects of volume fraction (15-30%) of SiC particulate reinforcements on the corrosion behavior of SiCp/7091 Al composites in the 3.5% NaCl solution were studied by electrochemical techniques and scanning electron microscopy. The results showed that the amount of SiC particulate reinforcements did not cause much difference in the corrosion behavior of SiCp/7091 Al composites but the corrosion rate was proportional to the amount of SiCp reinforcement. And numerous pits and severe dissolution of the matrix was observed probably due to the discontinuities and galvanic effects between Al matrix and SiC reinforcements.

Determining Factors for the Protectiveness of the Passive Film of FeCrN Stainless Steel Formed in Sulfuric Acid Solutions

  • Ha, Heon-Young;Lee, Tae-Ho
    • Corrosion Science and Technology
    • /
    • 제12권4호
    • /
    • pp.163-170
    • /
    • 2013
  • In NaCl solutions acidified with $H_2SO_4$, Fe20Cr1.1N alloy showed enhanced pitting corrosion resistance than Fe20Cr alloy. An XPS analysis revealed that the passive film of Fe20Cr1.1N alloy contained higher cationfraction of Cr than that of Fe20Cr alloy, and nitrogen was incorporated into the film. In addition, it was found that the passive film of Fe20Cr1.1N alloy was thinner and had higher oxygen vacancy density than that of Fe20Cr alloy. Based on these observations, it was concluded that the chemical composition was the determining factor for the protectiveness of the passive film of Fe20Cr based alloy in dilute $H_2SO_4$ solution.

마이크로 드로플릿 셀 기법을 이용한 예민화 된 304 스테인리스강의 미세전기화학 특성 (Micro-electrochemical Characteristics of Sensitized 304 Stainless steel Using Micro-droplet cell Techniques)

  • 김규섭;이재봉
    • Corrosion Science and Technology
    • /
    • 제9권6호
    • /
    • pp.300-309
    • /
    • 2010
  • The influences of sensitization on localized corrosion resistance of 304 stainless steel, were investigated, using micro-dropletcell techniques. Micro-droplet cell allows one to align the micro-electrode to the desired spot of the working electrode and measure directly local current with the potentiodynamic polarization, linear polarization and a.c. impedance. Micro-electrochemical tests were carried out inside of the grain and on grain boundaries separately. It was found that sensitization decreased the pitting potential, increasing corrosion current density around grain boundaries. Galvanic current density was also measured between grain and grain boundaries.

은의 부식 및 변식에 미치는 전해질 용액에 따른 ICCP 전압의 영향 (Effect of ICCP Potential with Electrolyte on Corrosion and Discolor of Silver)

  • 신병현;김도형;정원섭
    • 한국표면공학회지
    • /
    • 제53권5호
    • /
    • pp.207-212
    • /
    • 2020
  • Silver is an inexpensive precious metal and is used in various jewelry in Asia. Although silver has high potential, it has corrosion resistance that is vulnerable to boiling sulfuric acid and nitric acid. So, silver research is needed to prevent the corrosion with environment. But silver corrosion is not studied. sulfuric acid make the uniform corrosion and chloride ion make the pitting corrosion. ICCP inhibits the corrosion because it offset electrons. This study used a potential from - 4 V to 4 V to check the effect of potential. Corrosion rate is lowet at -1 V.

Sintered Duplex Stainless Steels Corrosion Properties

  • Dobrzanski, L.A.;Brytan, Z.;Grande, M. Actis;Rossob, M.;Park, Woo-Young;Kim, Cheol-Su
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.583-584
    • /
    • 2006
  • This work presents mechanical properties and corrosion resistance of duplex stainless steels obtained through powder metallurgy starting from austenitic, martensitic powders by controlled addition of alloying elements in the right quantity to obtain the chemical composition of the structure similar to biphasic one. In the mixes preparations the Schaffler's diagram was taken into consideration. Prepared mixes of powders have been sintered in a vacuum furnace with argon backfilling. After sintering rapid cooling was applied using nitrogen. Corrosion properties have been studied through electrochemical methods in 1M NaCl.

  • PDF

Electrochemical corrosion behavior of atmospheric-plasma-sprayed copper as a coating material for deep geological disposal canisters

  • Sung-Wook Kim;Gha-Young Kim;Young-Ho Lee;Jun-Hyuk Jang;Chung-Won Lee;Jeong-Hyun Woo;Seok Yoon
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4032-4038
    • /
    • 2023
  • Cu, which exhibits excellent corrosion resistance in underground environments, has been investigated as a canister material for use in the deep geological disposal of spent nuclear fuels. In this study, the technical viability of atmospheric plasma spraying for producing Cu-coated canisters was investigated. A high-purity Cu film (millimeter scale) was deposited onto a stainless-steel substrate using a plasma gun with a shroud structure. Potentiodynamic polarization studies revealed that the Cu film exhibited a sufficiently low corrosion rate in the groundwater electrolyte. In addition, no pitting corrosion was observed on the Cu film surface after accelerated corrosion studies. A prototype cylindrical Cu film was fabricated on a 1/20 scale on a stainless-steel tube to demonstrate the scalability of atmospheric plasma spraying in producing Cu-coated canisters.