• Title/Summary/Keyword: Pitch Period

Search Result 188, Processing Time 0.025 seconds

A Study on the Correlation Between Sasang Constitution and Sound Characteristics Used Harmonics and Formant Bandwidth (Harmonics(배음)와 Formant Bandwidth(포먼트 폭)를 이용한 음성특성(音聲特性)과 사상체질간(四象體質間)의 상관성(相關性) 연구(硏究))

  • Park, Sung-Jin;Kim, Dal-Rae
    • Journal of Sasang Constitutional Medicine
    • /
    • v.16 no.1
    • /
    • pp.61-73
    • /
    • 2004
  • This study was prepared to investigate the correlation between Sasang constitutional groups and voice characteristics using voice analysis system(in this study, CSL). I focused on the voice characteristics in terms of harmonics, Formant frequency and Formant Bandwidth. The subjects were 71 males. I classified them into three groups, that is Soeumin group, Soyangin group and Taeumin group. The classification method of Constitution used two ways, QSCCII(Questionnarie for the Sasang Constitution Classification II) and Interview with a specialist in Sasang Constitution. So 71 people were categorized into 31 Soeumin(people), 18 Soyangin(people) and 22 Taeumin(people). Pitch is approximately similar to the fundamental frequency(F0) in voices. Shimmer in dB gives an evaluation of the period-to-period variability of the peak-to-peak amplitude within the analyzed voice sample. FFT(Fast Fourier Transform) method in CSL can display sampled voices into harmonics. H1 is the first peak and h2 is the second peak in the harmonics. The amplitude difference of h1 and h2(h1-h2) can be explained as the speaker's phonation type, And Formant frequency and bandwidth can be explained as the speaker's vocal tract. So I checked the harmonics and Formant frequency and Bandwidth as the voice parameters. First I have captured /e/ voices from all subjects using microphone. And then I analyzed /e/ voices with CSL. Power Spectrum and Formant History is the menu in the CSL which can display harmonics and Formant frequency and bandwidth. The results about the correlation between Sasang Constitutional Groups and voice parameters are as follows; 1. There is no significant amplitude difference of harmonics(h1-h2) among three groups. 2. There is the significant difference between Soeumin Group and Soyangin Group in Formant Frequency 1 and Formant Bandwidth 1(p<0.05). Any other parameters have no significance. I assume that Soyangin Group has clearer and brighter voice than Soeumin Group according to the Formant Bandwidth difference. And I think its result has coincidence with the context of "Dongyi Suse Bowon" and "Sasangimhejinam".

  • PDF

A Study on CFD Analysis to Investigate the Effects of Different Feed Rate into the High Temperature H2SO4 Transferring Pump at Fixed Frequency

  • Choi, Jung-Sik;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.3
    • /
    • pp.304-311
    • /
    • 2014
  • In this study, to apply hydrogen energy to ship engine and to generate effective hydrogen production, we investigated the effects of high temperature $H_2SO_4$ feed rate and cooling water rate to pump parts with fixed frequency needed to reciprocate motion and a simulation was conducted at each condition. In the fixed frequency and cooling water inlet flow rate of 0.5 Hz and 3.9 kg/s, we changed the high temperature $H_2SO_4$ flow rate to 47.46 kg/s (it is 105 % of 45.2 kg/s), 49.72 kg/s (110 %), and 51.98 kg/s (115 %). Also, at 0.5 Hz and 45.2 kg/s of frequency and high temperature $H_2SO_4$ flow, the thermal hydraulic analysis was performed at the condition of 95 % (3.705 kg/s), 90 % (3.51 kg/s), and 85 % (3.315 kg/s). In overall simulation cases, the physical properties of materials are more influential to the temperature increase in the pump part rather than the changes on the feed rate of high temperature $H_2SO_4$ and cooling water. A continuous operation of pump was also capable even if the excess feed of high temperature $H_2SO_4$ of about 15 % or the less feed of cooling water of about 15 % were performed, respectively. When the increasing feed of high temperature $H_2SO_4$ of up to 5 %, 10 %, and 15 % were compared with base flow (45.2 kg/s), the deviation of time period rose to a certain temperature and ranged from 0 to 4.5 s in the same position (same material). In case of cooling water, the deviation of time period rose to a certain temperature and ranged from 0 to 5.9 s according to the decreasing feed changes of cooling water at 5 %, 10 %, and 15 % compared to a base flow (3.9 kg/s). Finally, the additional researches related to the two different materials (Teflon and STS for Pitch and End-plate), which are concerned about the effects of temperature changes to the parts contacting different materials, are needed, and we have a plan to conduct a follow-up study.

Detecting lies through suspect's nonverbal behaviors in the investigation scene (군 수사현장에서 용의자의 비언어적 행동을 이용한 거짓말 탐지)

  • Si Up Kim;Woo Byoung Jhon;Chung Hyun Jeon
    • Korean Journal of Culture and Social Issue
    • /
    • v.12 no.2
    • /
    • pp.101-114
    • /
    • 2006
  • This study was examined the effective nonverbal behavior cues of detecting suspects' lies in the investigation scene. In order to search the suspects who drank the alcohol liquor without a permission, 18 soldiers were interviewed. 8 solders had drunken alcohol and had lied when was asked(lie group). The other 10 soldiers hadn't drunken alcohol and had told the truth(truth group). The mean frequencies of nonverbal behaviors were compared lie group with truth group. The following behaviors were measured by frequency: vocal characteristics (high pitch of voice, speech hesitations, speech error, frequency of pauses, period of pauses, latency period), facial characteristics (gaze, smile, touching face, blinking, facial micro-expression), body movement (illustrators, hand and finger movement, leg and foot movement, head movement, trunk movement, shifting position). As results, this study found that deception cues were periods and frequencies of pause, micro-expression, head movements. The lie group had less periods and frequencies of pause, and more micro-expression, head movements than truth group. But, this study didn't found Othello's error cues.

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Modeling and Controller Design for Attitude Control of a Moving Satellite (이동하는 위성의 자세제어를 위한 모델링 및 제어기 설계)

  • Lee, Woo-Seung;Park, Chong-Kug
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.1
    • /
    • pp.19-29
    • /
    • 2000
  • Because the previous simulation tool for attitude control of satellite was designed for the modeling of rigid body and PD controller, the attitude error can be made more than the limitation value for keeping for communication link, and then the communication link can be lost at moving of satellite. So, for rapid attitude restoration and design of stable and modernized controller, the modelling of rigid body and flexible body structure for moving GEO and LEO satellites were performed. Also the minimum time controller is designed for the rapid restoration of attitude error at communication broken and to minimize the disconnection period from ground communication system during the satellite stationkeeping. The linear regulator is designed using the space state vector that is better than accuracy and stability of PD controller. Firstly the simulation was performed for comparison of the rigid and stability of PD controller. Firstly the simulation was performed for comparison of the rigid and flexible models using PD controller and the case of the pitch angle changing by ground command, and the case of the periodic north-south stationkeeping are performed for the analysis of response characteristics of each controller when the attitude is changed. As a result, the flexible body model represents more sililar results of real situation than the rigid body model. The minimum time controller can restore 7 times rapidly than PD controller for its lost attitude. The linear regulator has several merits for capability of adaptation against the external disturbance, stability and response time. In future, we can check the estimated results using this satellite model and controller for real operation. Futhermore the development of new controller and training can be supported.

  • PDF

Analysis of Clinical and Radiographic Outcome of the Reconstructive Surgery for the Cavovarus Foot Deformity (요내반족 변형에 대한 재건수술의 임상적 및 방사선학적 결과 분석)

  • Jung, Hong-Geun;Park, Jae-Yong;Lee, Dong-Oh;Eom, Joon-Sang;Chung, Seung-Hee
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • Purpose: Reconstructive surgeries for equinocavovarus foot deformities are quite variable, including hind-midfoot osteotomy or arthrodesis, soft tissue procedure, tendon transfers, etc. Comprehensive evaluation of the deformity and its etiology is mandatory for achievement of successful deformity correction. Few studies in this field have been reported. We report on the clinical and radiographic outcome of reconstruction for cavovarus foot deformities. Materials and Methods: The study is based on 16 feet with cavovarus foot deformities that underwent bony and soft tissue reconstructive surgery from 2004 to 2008. We evaluated the etiologies, varieties of surgical procedures performed, pain score, functional scores, and patient satisfaction and measured the radiographic parameters. Results: The average age at the time of surgery was 39.4 years old, with a male/female ratio of 9/4 and an average follow-up period of 23.9 months (range, 12~49 months). The etiologies of the cavovarus deformity were idiopathic 7 feet, residual poliomyelitis 5 feet, Charcot-Marie-Tooth disease 2 feet, and Guillain-Barre syndrome and hemiplegia due to cerebrovascular accident sequela 1 foot each. Lateral sliding calcaneal osteotomies were performed in 12 feet (75%), followed by Achilles tendon lengthening and plantar fascia release in 11 feet (69%), and first metatarsal dorsiflexion osteotomy/arthrodesis and tendon transfer in 10 feet (63%). Visual analogue scale pain score showed improvement, from an average of 4.2 to 0.5 points. American Orthopaedic Foot and Ankle Society ankle-hindfoot score showed significant improvement, from 47.8 to 90.0 points (p<0.05). All patients were satisfied. Ankle range of motion improved from $27.5^{\circ}$ to $46.7^{\circ}$. In radiographic measurements, calcaneal pitch angle improved from $19.1^{\circ}$ to $15.8^{\circ}$, Meary angle from $13.0^{\circ}$ to $9.3^{\circ}$, Hibb's angle from $44.3^{\circ}$ to $37.0^{\circ}$, and tibio-calcaneal axis angle from varus $17.5^{\circ}$ to varus $1.5^{\circ}$ Conclusion: We achieved successful correction of cavovarus foot deformities by performing appropriate comprehensive reconstructive procedures with improved functional, radiographic measures and high patient satisfaction.

The characteristics of nuclear powered submarine and the use of enriched uranium (원자력 추진 잠수함의 특성과 농축우라늄 사용)

  • Jang, Jun-Seop
    • Strategy21
    • /
    • s.41
    • /
    • pp.261-293
    • /
    • 2017
  • Nuclear power is a way of attaining an enormous amount of energy with relatively small amount of resources and after it has been introduced to the submarine since 1954, there are approximately 150 of nuclear powered submarine currently on a mission around the world. This is due to the maneuverability, mountability and covertness of nuclear submarines. However, there are other tasks, not only the high level of nuclear technology that are needed to be dealt with in order to construct nuclear powered submarine. The biggest task of all is to secure the enriched uranium. Accordingly, this research is about the way of enriching and securing the nuclear fuel that are used in the nuclear submarine with the characteristics, merits and demerits of the nuclear submarine. Due to the fact that the pressurized water reactor in South Korea is the reactor that was originally built for the development of nuclear powered submarine, many parts is designed to be suitable for the submarine propulsion. However, in order to apply this to submarine it is needed to consider additional requests such as the position of reactor, accident-coping system, radioactive covering, reactor output adjustment and ship's pitch and roll in order to apply this to submarine. Nuclear submarines have much higher speed based on the powerful propulsion in comparison with diesel-electric submarine and also have bigger loading area. Besides, there is no need to snorkel and they also have advantages in covertness with the multi-noise proof system. The nuclear technology in South Korea has seen the dramatic development since 1962 and in 1998 reached to the level that we have succeeded in the localization of nuclear plant and exported the world-class one-piece small-sized reactor (SMART) to UAE. To operate these reactors, we import the whole quantity of low-enriched uranium and having our own uranium enrich facility is not probable because of the budget and international regulations. With the ROK/US nuclear agreement revised on 2015 November, the enrichment of uranium that are available without special permission has changed up to 20%. According to the assumption that we use the 20% enrichment of Uranium on U.S. virginia class submarine, it is necessary to change the fuel after 11 years and it will cause additional cost of 1 billion dollars. But the replace period by the uranium's enrichment rate is not fixed so that it is possible to change according to the design of reactor. Therefore, I would like to make a suggestion on two types of design concepts of nuclear submarine that can be operated for 30 years without nuclear fuel change by using the 20% enriched uranium from ONNp.First of all, it is possible by increasing the size of reactor by 3 times and it results in the 1,000t increase of the weight. And secondly, it is by designing the one piece reactor to insert devices such as steam turbine, condenser into the inside of nuclear core like the Rubis class submarines of France.

Corpus-based Korean Text-to-speech Conversion System (콜퍼스에 기반한 한국어 문장/음성변환 시스템)

  • Kim, Sang-hun; Park, Jun;Lee, Young-jik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.24-33
    • /
    • 2001
  • this paper describes a baseline for an implementation of a corpus-based Korean TTS system. The conventional TTS systems using small-sized speech still generate machine-like synthetic speech. To overcome this problem we introduce the corpus-based TTS system which enables to generate natural synthetic speech without prosodic modifications. The corpus should be composed of a natural prosody of source speech and multiple instances of synthesis units. To make a phone level synthesis unit, we train a speech recognizer with the target speech, and then perform an automatic phoneme segmentation. We also detect the fine pitch period using Laryngo graph signals, which is used for prosodic feature extraction. For break strength allocation, 4 levels of break indices are decided as pause length and also attached to phones to reflect prosodic variations in phrase boundaries. To predict the break strength on texts, we utilize the statistical information of POS (Part-of-Speech) sequences. The best triphone sequences are selected by Viterbi search considering the minimization of accumulative Euclidean distance of concatenating distortion. To get high quality synthesis speech applicable to commercial purpose, we introduce a domain specific database. By adding domain specific database to general domain database, we can greatly improve the quality of synthetic speech on specific domain. From the subjective evaluation, the new Korean corpus-based TTS system shows better naturalness than the conventional demisyllable-based one.

  • PDF

Strength Performance Evaluation of Threaded Nail Joints of Wooden Retaining Wall Using Pitch Pine (Pinus rigida Miller) Square Timber (리기다 소나무 정각재를 사용한 목재옹벽의 직결나사못 접합부 내력 성능 평가)

  • Song, Yo-Jin;Kim, Keon-Ho;Lee, Dong-Heub;Hwang, Won-Joung;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.53-59
    • /
    • 2011
  • A connection was made between a single stretcher and 2 headers with 2 threaded nails (Type-A), and another one between 2 stretchers and 2 headers with 4 threaded nails (Type-B) to use as specimens. Type-C was the stretchers that are connected with 2 threaded nails by half lap joint at end-distance 5D to reinforce Type-B, Type-C1 the stretchers that are connected by half lap joint at end-distance 10D, and Type-C2 with 3 threaded nails at end-distance 10D. Compressive shear strength of Type-C, the supplementation of Type-B, was decreased by 30%, compared with that of Type-B. Those of Type-B and Type-C1 that used longer end-distance than Type-C were about the same, and that of Type-C2 connected with 3 threaded nails was 1.28-times stronger than that of Type-C1. Connection of the retaining wall using existing square timber has a problem between long and short stretchers and 2 headers. So it was investigated in the experiment to replace it. Therefore, if Type-B is replaced with Type-C2 in constructing the retaining wall, the crack and the rupture of timber caused by threaded nail as well as construction period can be reduced, and also it can be expected to increase their own strength.

Effects of low-dose topiramate on language function in children with migraine

  • Han, Seung-A;Yang, Eu Jeen;Kong, Younghwa;Joo, Chan-Uhng;Kim, Sun Jun
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.7
    • /
    • pp.227-231
    • /
    • 2017
  • Purpose: This study aimed to verify the safety of low-dose topiramate on language development in pediatric patients with migraine. Methods: Thirty newly diagnosed pediatric patients with migraine who needed topiramate were enrolled and assessed twice with standard language tests, including the Test of Language Problem Solving Abilities (TOPs), Receptive and Expressive Vocabulary Test, Urimal Test of Articulation and Phonology, and computerized speech laboratory analysis. Data were collected before treatment, and topiramate as monotherapy was sustained for at least 3 months. The mean follow-up period was $4.3{\pm}2.7months$. The mean topiramate dosage was 0.9 mg/kg/day. Results: The patient's mean age was $144.1{\pm}42.3months$ (male-to-female ratio, 9:21). The values of all the language parameters of the TOPs were not changed significantly after the topiramate treatment as follows: Determine cause, from $15.0{\pm}4.4$ to $15.4{\pm}4.8$ (P>0.05); making inference, from $17.6{\pm}5.6$ to $17.5{\pm}6.6$ (P>0.05); predicting, from $11.5{\pm}4.5$ to $12.3{\pm}4.0$ (P>0.05); and total TOPs score, from $44.1{\pm}13.4$ to $45.3{\pm}13.6$ (P>0.05). The total mean length of utterance in words during the test decreased from $44.1{\pm}13.4$ to $45.3{\pm}13.6$ (P<0.05). The Receptive and Expressive Vocabulary Test results decreased from $97.7{\pm}22.1$ to $96.3{\pm}19.9months$, and from $81.8{\pm}23.4$ to $82.3{\pm}25.4months$, respectively (P>0.05). In the articulation and phonology validation in both groups, speech pitch and energy were not significant, and all the vowel test results showed no other significant values. Conclusion: No significant difference was found in the language-speaking ability between the patients; however, the number of vocabularies used decreased. Therefore, topiramate should be used cautiously for children with migraine.