Strength Performance Evaluation of Threaded Nail Joints of Wooden Retaining Wall Using Pitch Pine (Pinus rigida Miller) Square Timber  

Song, Yo-Jin (Department of Forest Biomaterials Engineering, College of Forest and Environmental Sciences, Kangwon National University)
Kim, Keon-Ho (Department of Forest Biomaterials Engineering, College of Forest and Environmental Sciences, Kangwon National University)
Lee, Dong-Heub (Div. of Environmental Wooden Material Engineering, Dept. of Green Resources Utilization, Korea Forest Research Institute)
Hwang, Won-Joung (Div. of Environmental Wooden Material Engineering, Dept. of Green Resources Utilization, Korea Forest Research Institute)
Hong, Soon-Il (Department of Forest Biomaterials Engineering, College of Forest and Environmental Sciences, Kangwon National University)
Publication Information
Journal of the Korean Wood Science and Technology / v.39, no.1, 2011 , pp. 53-59 More about this Journal
Abstract
A connection was made between a single stretcher and 2 headers with 2 threaded nails (Type-A), and another one between 2 stretchers and 2 headers with 4 threaded nails (Type-B) to use as specimens. Type-C was the stretchers that are connected with 2 threaded nails by half lap joint at end-distance 5D to reinforce Type-B, Type-C1 the stretchers that are connected by half lap joint at end-distance 10D, and Type-C2 with 3 threaded nails at end-distance 10D. Compressive shear strength of Type-C, the supplementation of Type-B, was decreased by 30%, compared with that of Type-B. Those of Type-B and Type-C1 that used longer end-distance than Type-C were about the same, and that of Type-C2 connected with 3 threaded nails was 1.28-times stronger than that of Type-C1. Connection of the retaining wall using existing square timber has a problem between long and short stretchers and 2 headers. So it was investigated in the experiment to replace it. Therefore, if Type-B is replaced with Type-C2 in constructing the retaining wall, the crack and the rupture of timber caused by threaded nail as well as construction period can be reduced, and also it can be expected to increase their own strength.
Keywords
Pinus rigida Miller; wooden retaining wall; half lap joint;
Citations & Related Records
연도 인용수 순위
  • Reference
1 이동흡. 2009. 자연경관을 살리는 친환경 목재 옹벽. 산림조합중앙회 산림지 3월-8월호.
2 이양규, 한중근, 홍기권, 김영기. 2007. 간벌목재를 이용한 옹벽시스템의 안정성 분석. 대한토목학회 학술대회 10: 3518-3521.
3 右城猛. 2000. 新․擁壁の設計法と計算例. 理工図書.
4 花野秀昭. 1997. 治山工事における木材利用について. 治山 42(4): 84-88.
5 京都府森林保全課 治山係. 2000. 京都府における木製治山ダムの實施について. 治山 44(12): 272-276.
6 溝部孝博. 2000. 治山事業における木製型枠の施工事例. 治山 44(12): 277-279.