• 제목/요약/키워드: Piping vibration

검색결과 171건 처리시간 0.038초

Wire Rope형 진동완충장치 설계 (Design of Wire Rope snubbers)

  • 박종범;윤기갑;배병홍;이상국;이승학
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1192-1197
    • /
    • 2000
  • 발전소의 배관계에는 열변형은 허용하되 진동으로 인해 발생하는 응력을 줄이고 과도한 진동 작용시 배관계를 보호하기 위하여 유압식 또는 기계석 snubber가 설치되어 있다. 그러나 이들은 누유 가능성 및 사용수명 측면에서 보수 유지에 많은 경비가 소요된다. 최근 wire rope를 이용한 진동완충기가 도입되어 배관진동 완화에 매우 효과적임이 입증되었고 보수유지가 거의 필요없으므로 경제성도 높으나 고가의 수입가격으로 인해 국산화의 필요성이 절실하다.

  • PDF

4-자유도 배관 관절의 설계 및 동적 거동 예측 (Design and Dynamic Behavior Prediction of a 4-DOF Piping Joint)

  • 이윤용;강환국;이종림;임승철
    • 한국소음진동공학회논문집
    • /
    • 제26권3호
    • /
    • pp.298-307
    • /
    • 2016
  • In the building process of FPSOs(floating production, storage and offloading units) is the increasing demand of high performance piping joints that can be installed on its turret system and maintain smooth and long-term flow of ultra-high pressure crude oil, being subjected to external excitations such as wind and wave on the sea. Following such a trend, in this paper, a new-type piping joint of four effective degrees of freedom has been designed, and its dynamic characteristics predicted through mathematical modeling and computer simulations. Moreover, via an example it was shown how the yaw motion in particular can be independently controlled for future durability test despite strong kinetic couplings.

간극효과를 고려한 증기발생기 전열관의 3차원 유한요소해석 (3-D Finite Element Analyses of Steam Generator Tubes Considering the Gap Effects)

  • 조영기;박재학
    • 한국압력기기공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.51-56
    • /
    • 2011
  • Steam generator is one of the main equipments that affect safety and long term operation in nuclear power plants. Fluid flows inside and outside of the steam generator tubes and induces vibration. To prevent the vibration the tubes are supported by AVB (anti vibration bar). When the steam generator tube contact to AVB, it is damaged by the accumulation of wear and corrosion. Therefore studies are required to determine the effects of the gap between the steam generator tube and AVB. In order to obtain the stress and the displacement distributions of the steam generator tube, three dimensional finite element analyses were performed by using the commercial program ANSYS. Using the calculated the stress and the displacement distributions, the static residual strength of the steam generator tube can be evaluated. The results show that the stress and displacement of the steam generator tube increase significantly compared with the results from a zero-gap model.

적외선 열화상 카메라를 이용한 탄소강관 용접부 결함검출 (Defect Detection of Carbon Steel Pipe Weld Area using Infrared Thermography Camera)

  • 권대주;정나라;김재열
    • Tribology and Lubricants
    • /
    • 제30권2호
    • /
    • pp.124-129
    • /
    • 2014
  • The piping system accounts for a large portion of the machinery structure of a plant, and is considered as a very important mechanical structure for plant safety. Accordingly, it is used in most energy plants in the nuclear, gas, and heavy chemical industries. In particular, the piping system for a nuclear plant is generally complicated and uses the reactor and its cooling system. The piping equipment is exposed to diverse loads such as weight, temperature, pressure, and seismic load from pipes and fluids, and is used to transfer steam, oil, and gas. In ultrasound infrared thermography, which is an active thermography technology, a 15-100 kHz ultrasound wave is applied to the subject, and the resulting heat from the defective parts is measured using a thermography camera. Because this technique can inspect a large area simultaneously and detect defects such as cracks and delamination in real time, it is used to detect defects in the new and renewable energy, car, and aerospace industries, and recently, in piping defect detection. In this study, ultrasound infrared thermography is used to detect information for the diagnosis of nuclear equipment and structures. Test specimens are prepared with piping materials for nuclear plants, and the optimally designed ultrasound horn and ultrasound vibration system is used to determine damages on nuclear plant piping and detect defects. Additionally, the detected images are used to improve the reliability of the surface and internal defect detection for nuclear piping materials, and their field applicability and reliability is verified.

비정상 유동을 포함한 파이프계의 안정성 해석 (Stability Analysis of Piping System Conveying Unsteady Flow)

  • 박철희;이우식;홍성철;김태룡
    • 대한기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1512-1521
    • /
    • 1991
  • 본 연구에서는 유속과 압력등이 시간과 위치의 함수로 표현되는 비정상 유체 가 흐를 때 그 유동 특성이 파이프계에 미치는 영향을 고찰하기 위해 비정상 유동을 포함한 파이프계의 운동방정식을 유도하고 유동 변수가 파이프계의 안정성에 미치는 영향을 연구하였다.

함정탑재 펌프류 장비의 공기음/고체음 저감 사례 연구 (Case study on the reduction of airborne and structure-borne noise of a shipboard pump)

  • 김상렬;김현실;김봉기;김재승;강현주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.411-415
    • /
    • 2007
  • The reduction of airborne and structure-borne noise of a shipboard pump for a navel ship is very important because the noise levels of the pump must not exceed criteria such as MIL-STD. In this paper, several practical examples of reducing the noise levels are presented. The examples show that the inadequate rotor-balancing and shaft-alignment results in the increase of the structure-borne noise on all lower mounts. It is also found that the unequal loading on mounts can cause the dramatically increasing the noise levels on certain local positions. Since the piping system arrangement such as valve location, flexible joint, and elbow location affects on the noise measurement, care must be taken to minimize the unnecessary noise from the piping system.

  • PDF

함정용 펌프의 공기음 및 고체음저감 (Reduction of airborne and structure-borne noise of naval ship pump)

  • 김현실;김재승;강현주;김봉기;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.942-947
    • /
    • 2002
  • In this study, reduction of airborne and structure-borne noise of naval ship pump is presented. Since piping system arrangement such as valve location, flexible joint, pipe diameter and elbow location, discharge basin affect greatly on the noise measurement, care must be taken to minimize the unnecessary noise from the piping system. It is shown that structure-borne noise of the motor with single resilient mount system exceeds criterion. Therefore, it is concluded that double resilient mount system is inevitable. Two kinds of mount is studied for upper mount; spring and rubber type. Although both mounts show good performance at low frequency including rpm frequency, 63Hz, spring mount is found to be inadequate at high frequency, because spring coil acts as a path for SBN.

  • PDF