Reduction of airborne and structure-borne noise of naval ship pump

함정용 펌프의 공기음 및 고체음저감

  • 김현실 (한국기계연구원 음향연구그룹) ;
  • 김재승 (한국기계연구원 음향연구그) ;
  • 강현주 (한국기계연구원 음향연구그) ;
  • 김봉기 (한국기계연구원 음향연구그) ;
  • 김상렬 (한국기계연구원 음향연구그룹)
  • Published : 2002.05.01

Abstract

In this study, reduction of airborne and structure-borne noise of naval ship pump is presented. Since piping system arrangement such as valve location, flexible joint, pipe diameter and elbow location, discharge basin affect greatly on the noise measurement, care must be taken to minimize the unnecessary noise from the piping system. It is shown that structure-borne noise of the motor with single resilient mount system exceeds criterion. Therefore, it is concluded that double resilient mount system is inevitable. Two kinds of mount is studied for upper mount; spring and rubber type. Although both mounts show good performance at low frequency including rpm frequency, 63Hz, spring mount is found to be inadequate at high frequency, because spring coil acts as a path for SBN.

Keywords