• Title/Summary/Keyword: Pipe Noise

Search Result 438, Processing Time 0.036 seconds

A study on the fluid noise in the pipe (파이프 내부의 유동소음에 관한 연구)

  • Hwang, Ki-Soo;Choi, Myung-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1435-1439
    • /
    • 2009
  • Drainage noise with making think about what they do disturbs neighborhoods live under source of noise. elbow pipe built in the house. the general elbow pipe has a rectangular elbow because of easiness when the plan set up or executing. therefore, free falling fluid impacts on the wall of the elbow pipe almost at one point. in this paper, to disperse the potential energy, the shock decentralizes from tiny area to large area. And It is considered how the characteristics change according to the noise of transformed shape of pipe, then researched the effectiveness of transformed pipe configuration.

  • PDF

Analysis for Reducing Vibration Transmitted from the Sea-Water Conveying Pipe to the Hull (선체로 전달되는 해수 이송 배관의 진동 저감 분석)

  • Han, Hyung-Suk;Park, Mi-Yoo;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.145-151
    • /
    • 2008
  • URN(Underwater Radiated Noise) is one of the important performances of the battle ship related to the stealth. The main source of the URN is the structure-borne noise on the hull. And the pipe vibration transmitted to the hull is the main source of the structure-borne noise when the speed of the ship is lower than CIS(Cavitation Inception Speed). In this paper, the vibration isolator(rubber mount) for the pipe system is described in order to reduce the structure-borne noise transmitted to the hull. The vibrations on the sea-water conveying pipes and their supports are measured in order to know how much vibration occurs on those positions. Based on these test results, the improved design of the rubber mount is suggested by the parametric study and is verified numerically with the pipe and hull model.

  • PDF

An Experimental Study on the Propagation of Impulse Noise in the Far Sound Field (원음장에서의 충격성 소음전파에 관한 실험적 연구)

  • 송화영;제현수;이주원;이성태;이동훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.852-855
    • /
    • 2004
  • This experimental study describes the propagation characteristics of the impulse noise emitted from the exit of a straight pipe attached to the open end of a simple shock tube. The sound pressure level and directivity of the impulse noise propagating from the exit of pipe with several different diameters are measured in the far sound fold for the range of the incident shock wave Mach number between 1.07 and 1.26. The experimental results showed that the peak values of impulse noises had a strong dependance on the exit diameter of a pipe and the shock wave Mach number. The impulse noise had the directivity propagating toward to the pipe axis and the characteristics of inverse square law of propagation distance. Moreover, it was shown that the one-third octave band SPL of impulse noise was almost constant regardless of the frequency band.

  • PDF

Reduction of Fire Main Pipe System's Vibration Using Back Flow Prevent Globe Valve (역류방지 글로브 밸브를 이용한 소화 주관계의 진동개선)

  • Park, Mi-You;Han, Hyung-Suk;Lee, Seuk-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.518-523
    • /
    • 2009
  • Main source of URN(Underwater Radiated Noise) which is related to the ship's survivability is divided into two groups. Cavitation is main source of URN when the speed of ship is upper than CIS(Cavitation Inception Speed). But when the speed of ship is lower than CIS, main source of URN is structure-borne noise on the hull which is originated from propulsion system, pump system or transmitted vibration of pipe system. In this paper, to reduce the vibration of discharge pipe and valve system, back flow prevent globe valve and new rubber mount are applied to the ship. As the result of applying new valve and mount, the vibration is reduced drastically.

  • PDF

Reduction of Fire Main Pipe System's Vibration Using Back Flow Prevent Globe Valve (역류방지 글로브 밸브를 이용한 소화 주관계의 진동개선)

  • Park, Mi-You;Han, Hyung-Suk;Lee, Seuk-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.6
    • /
    • pp.599-606
    • /
    • 2009
  • Main source of URN(underwater radiated noise) which is related to the ship's survivability is divided into two groups. Cavitation is the main source of URN when the speed of ship is upper than CIS(cavitation inception speed). But when the speed of ship is lower than CIS, the main source of URN is the structure-borne noise on the hull which is originated from propulsion system, pump system and trnasmitted vibration of the pipe system. In this paper, to reduce the vibration of discharge pipe and valve system, back flow prevent globe valve and new rubber mount are applied to the ship. As the result of applying new valve and mount, the vibration is reduced drastically.

Vibration Analysis of Discharge Pipe with Fluid Pulsation in a Rotary Compressor (유체 맥동을 고려한 압축기 토출 배관의 진동 응답 해석)

  • 서영수;정의봉
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1049-1054
    • /
    • 2002
  • Fluid Pulsation in pipe usually cause several forces and these forces make mechanical vibration and noise. Protecting pipe from mechanical vibration is very important problem because vibration make pipe damage and break. To analyze pipe, we must formulate both the fluid pulsation force and vibration of pipe. In this paper fluid force from pulsation is modeled by Fluid Dynamics and solved by FEM(finite element method). The discharge pipe is also modeled by the FEM with use of 6 dof beam model. The acceleration of discharge pipe is estimated by the suggested method in this paper. The comparision of estimated results with experimental results show good agreement, which verified the validation of this method

  • PDF

Structural Vibration and Noise Characteristics of Pipe Structures (파이프 구조물의 구조진동 및 소음특성)

  • Ryu B.J.;Shin G.B.;Han H.H.;Lee G.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1459-1462
    • /
    • 2005
  • The paper deals with the structural vibration and noise characteristics of pipe structures. In general, A structure bone noise has a great effect on the drain noise of toilets, and depends on the natural frequency of the related structures. In order to measure and to find the relationships between structural vibration and noise of the pipe structures, some experiments have been performed. Through the experiments, impact acceleration signal in time domain and magnitude of transfer function in the frequency domain have been investigated for three kinds of pipes. Transmission loss of pipes depending on the frequency ranges was also found by using small speakers as a sound source.

  • PDF

Reduction of Refrigerant-induced Noise of the Refrigerator by Modification of the Evaporator Inlet Pipe (증발기 입구 배관의 구조 개선을 통한 냉장고 냉매 소음 저감)

  • Kim, Min-Seong;Han, Hyung-Suk;Kim, Tae-Hun;Jeong, Wei-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.10
    • /
    • pp.1012-1020
    • /
    • 2009
  • This research is focused on the experimental study of the noise induced by two-phase refrigerant flow in the evaporator. The two-phase flow in the evaporator has various flow patterns. The effects of two-phase flow pattern's characteristics on the noise of the evaporator are investigated experimentally. The experimental data shows that the generated noise is mainly related to the layout of the pipe and the certain two-phase flow patterns such as the churn and slug flow. Based on these results, we removed the unnecessary vertical pipe and changed the pipe diameter of the evaporator - inlet into small one in order to avoid the intermittent flow condition. The noise level of newly-designed inlet-pipe of the evaporator was measured experimentally by refrigerant-supplying equipment and compared with that of conventional one.

A Study on the Reduction Method of Heavy-weight floor impact sound and Plumbing noise in Decrepit Apartment houses (노후 아파트의 바닥충격음 및 급·배수 소음 저감방안에 관한 연구)

  • Joo, Moon Ki;Han, Myung Ho;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • The noise in apartment buildings are major factor that determine the quality of indoor noise environment. Particularly, the noise from children's running footsteps and plumbing noise have caused the residents who live in decrepit apartment houses to uncomfortable environment. And as time go by, sound performance are getting worse according to the aging of the facilities. So this study deals with the plans to improve the sound performance of decrepit apartment house. To compare the noise reduction, we measured the heavy-weight impact sound level and plumbing noise level before and after changes the measurement conditions. As the results of measurements, the heavy-weight impact sound level were decreased when stiffness reinforcement were installed on slab. Especially the sound level were decreased 2.1-7.6dB in 50-80Hz of low frequency range. Instead of PVC pipe system, cast iron pipe and triple elbow drain pipe systems were installed. Noise level were decreased 15dB(A) in 250Hz. Noise level of pipe system's on the slab is less than under slab one. On the contrary water saving stool showed increasing the noise level.

Structure-Acoustic Coupling Analysis of a Pipe Using the Beam Element (보 요소를 이용한 파이프의 구조-음향 연성해석)

  • 서영수;정의봉;정호경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.282-287
    • /
    • 2004
  • Noise and vibrations in the pipe systems may be arisen from pumps. compressors, etc. The source mechanism is classified with the mechanical and hydraulic. Mechanical vibrations may be excited by the unbalance in rotating machinery. Hydraulic source may be generated in the turbulent flow. The vibro-acoustic behaviour of flexible, fluid-filled pipe system is a very complex and determined by two parameters: the frequency and the mass ratio of fluid and pipe wall. As the frequency increases, the mode number in the pipe increases. The mass ratio is close to one, the structure and the fluid are strongly coupled. In ease the diameter is very small to the length of pipe, the behaviour of pipe is same as a beam. The finite element formulation when the fluid and the structure are coupled is derived by using beam element. The Numerical results are compared with the package (Sysnoise) which is using the shell element.

  • PDF