Reduction of Refrigerant-induced Noise of the Refrigerator by Modification of the Evaporator Inlet Pipe |
Kim, Min-Seong
(부산대학교 대학원 기계공학부)
Han, Hyung-Suk (국방기술품질원) Kim, Tae-Hun (LG전자 냉장고 사업부) Jeong, Wei-Bong (부산대학교 기계공학부) |
1 | Christopher, E. B., 1995, “Cavitation and Bubble Dynamics,” Oxford University Press |
2 | Choi, S. W., Hwang, W. G., Seol, S. Y., Im, H. E. and Kim, S. S., 2004, “A Study on Reduction of Refrigerant Noise in Household Refrigerator,” Proceedings of the KSNVE Annual Autumn Conference 2004, pp. 1062-1066 |
3 | Hirakuni, S., 2004, “Noise Reduction Technology Caused by Refrigerant Two-phase Flow for Room Air Conditioner,” Japanese J. Multiphase Flow, Vol. 18, No. 1, pp. 23-30 |
4 | Lee, S. Y., Kim, B. J. and Kim, M. H., 1993, “Two-phase Flow Heat Transfer,” Daeyoung-Sa |
5 | Park, J. H., Chang, E. Y. and Park, Y. S., 1996, “Definition and Improvement of the Sound which was Generated by Bubbles at the Accumulator of the Evaporator,” Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 6, No. 4, pp. 513-519 |
6 | Minnaert, W. K., 1933, “On Musical Air Bubbles and the Sound of Running Water,” Phil. Mag.16, pp. 235-248 DOI |
7 | Strasberg, M., 1955, “Gas Bubbles as Sources of Sound in Liquids,” The Journal of the Acoustical Society of America, Vol. 28, No. 1, pp. 20-26 DOI |
8 | Baker, 1954, “Design of Pipe Lines for Simultaneous Flow of Oil and Sas,” Oil and Gas Journal, Vol. 53, pp.185-190 |
9 | Taitel, Y. and Dukler, A. E., 1976, “A Model for Predicting Flow Regime Transitions in Horizontal and Near Horizontal Gas-liquid Flow,” AIChE Journal, Vol. 22, pp. 47-55 DOI ScienceOn |
10 | Hashizume, K., 1983, “Flow Pattern and Void Fraction of Refrigerant Two-phase Flow in a Horizontal Tube,” Bulletin of the JSME, Vol. 26, pp. 1597-1602 DOI ScienceOn |
11 | Hewitt, G. F. and Roberts, D. N., 1969, “Studies of Two-phase Flow Patterns by Simultaneous Flash and X-Ray Photography,” AEREM2159 |
12 | Oshimowo, T. and Charles, M. E., 1974, “Vertical Two-phase Flow. Part1, Flow pattern Correlations,” Can, J. Chem. Eng., Vol. 52, pp. 25-35 DOI ScienceOn |
13 | Tomomi UMEDA, 1993, “Reduction of Noise Caused by Gas-liquid Two-phase Refrigerant Flow through an Expansion Valve,” JSME, Vol. 59, No. 557, pp. 243-248 DOI |
14 | Tatsumi KANNON, 1997, “Study on Noise Caused by Slug Flow through a Capillary Tube,” JSME, Vol. 63, No. 611, pp. 2392-2397 DOI |
15 | Han, H. S., Shigeo, A., Mo, J. Y., Lee, J. K. and Song, Y. J., 2006, “Analyzing for Refrigerant Induced Noise for Split Type Air Conditioner Indoor Unit,” Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 16, No. 3, pp. 240-246 DOI ScienceOn |