• 제목/요약/키워드: Pipe Junction

검색결과 44건 처리시간 0.027초

T-합류관의 유동특성 (Flow Characteristics of T-junction Pipe)

  • 김명관;배대석;권오붕;양정규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.528-533
    • /
    • 2005
  • This paper presents the study of flows at T-junction pipe with orifices. Experiments were carried out for several flow rates, orifice sizes, and pressure differences. Numerical simulations were also done to get more data for the wide range of flow rates. Experimental results and numerical ones are in a good agreement. Due to the effect of T-junction part, the flow rates at the lateral pipe are greater than those at straight pipe for the same pressure differences. When orifices were added, the effects of T-junction part on the ratio of flow rates and the ratio of loss coefficients reduced.

  • PDF

합류관에서의 손실과 유량 (Energy Loss and Flow Rate at Junction Pipe)

  • 김명관;권오붕
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.39-44
    • /
    • 2005
  • This paper presents the study of flows at T-junction pipe with orifices. Experiments were carried out for several flow rates, orifice sizes, and pressure differences. Numerical simulations were also done to get more data for the wide range of flow rates. Experimental results and numerical ones are in a good agreement. Due to the effect of T-junction part, the flow rates at the lateral pipe are greater than those at straight pipe for the same pressure differences. When orifices were added, the effects of T-junction part on the ratio of flow rates and the ratio of loss coefficients reduced.

  • PDF

유동망 시스템 해석을 위한 경계처리에 대한 보존형 유한체적법 (CONSERVATIVE FINITE VOLUME METHOD ON BOUNDARY TREATMENTS FOR FLOW NETWORK SYSTEM ANALYSES)

  • 홍석우;김종암
    • 한국전산유체공학회지
    • /
    • 제14권1호
    • /
    • pp.35-44
    • /
    • 2009
  • To adequately analyze flows in pipe or duct network system, traditional node-based junction coupling methods require the junction loss which is specified by empirical or analytic correlations. In this paper, a new finite volume junction coupling method using a ghost junction cell is developed by considering the interchange of linear momentum as well as the important wall-effect at junction without requiring any correlation on the junction loss. Also, boundary treatment is modified to preserve the stagnation enthalpy across boundaries, such as pipe-end and the interface between junction and branch. Also, the computational accuracy and efficiency of the Godunov-type finite volume schemes are investigated by tracing the total mechanical energy of rapid transients due to sudden closure of valve at downstream end.

Optimal Design of a Branched Pipe Network with Multiple Sources

  • Lee, Moon-Kyu
    • 대한산업공학회지
    • /
    • 제10권2호
    • /
    • pp.17-27
    • /
    • 1984
  • This paper is concerned with a branched pipe network system which transports some fluids or gas from multiple sources to multiple demand nodes. A nonlinear programming model is proposed for determining junction locations simultaneously with selection of pipe sizes and pump capacities such that the capital and operating costs of the system are minimized over a given planning horizon. To solve the model, a hierarchical decomposition method is developed with the junction location being the primary variable. With some values fixed for the primary, the other decision variables are found by linear programming. Then, using the postoptimality analysis of LP, junction locations are adjusted. We repeat this process until an optimum is approached. A simple example of designing a water distribution network is solved to illustrate the optimization procedure developed.

  • PDF

루프형 히트파이프를 이용한 LED 헤드램프 열적 특성 (LED Headlamp Thermal Characteristics by Looped Heat Pipe)

  • 노형철;박경석;강병도;손성만
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.443-444
    • /
    • 2006
  • The influence of the heat sources on LED junction temperature are Engine room air, Back plate, Electric power device, and so on. LED lamp cooling system is considered to be an important subject fur high light efficiency. Because LED Chip will be problem When LED junction temperature be over $135^{\circ}C$, In this Study, The Looped Heat Pipe System is considered to prevent LED Chip fall. The LHPS is consist of evaporator part, condenser part, heat pipe part. The working fluid of LHPS is HCFC-123. In this study, to prevent LED Chipfall, we study thermal characteristics for Looped Heat Pipe System with LED lamp.

  • PDF

감육이 존재하고 내압을 받는 T 분기관의 한계하중 평가식 (Limit Load Solutions for Piping Branch Junctions with local wall-thinning under Internal Pressure)

  • 류강묵;김윤재;이국희;박치용;이성호;김태룡
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1813-1817
    • /
    • 2007
  • The present work presents plastic limit load solutions for piping branch junctions with local wall-thinning, based on detailed three-dimensional (3-D) and small strain FE limit analyses using elastic-perfectly plastic materials. Three types of loading are considered; internal pressure, in-plane bending on the branch pipe and in-plane bending on the run pipe. The wall-tinning located on variable area of the piping branch junction is considered. A wide range of piping branch junction and wall-thinning geometries are considered. Comparison of the proposed solutions with FE results shows good agreement

  • PDF

유동망 시스템 해석을 위한 유령 정션 기법 (Ghost Junction Method for Flow Network System Analyses)

  • 홍석우;김종암
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.626-629
    • /
    • 2008
  • Numerical predictions on flow phenomena in pipe network systems have been considered as playing an important role in both designing and operating various facilities of piping or duct systems, such as water supply, tunnel or mine ventilation, hydraulic systems of automobile or aircraft, and etc. Traditionally, coupling conditions between junction and connected branches are assumed to satisfy conservation law of mass and to share an equal pressure at junction node. However, the conventional methodology cannot reflect momentum interactions between pipes sufficiently. Thus, a new finite volume junction treatment is proposed both to reflect the interchanges of linear momentums between neighbor branches at junction and to include the effect of wall at junction in present work.

  • PDF

저속 회전 시 배기시스템의 배압이 정숙성에 미치는 영향 (Influence of Back Pressure of an Exhaust System on Quietness at Low-Speed Rotation)

  • 강일석;양성모
    • 한국기계가공학회지
    • /
    • 제18권6호
    • /
    • pp.69-75
    • /
    • 2019
  • In recent years, the driving performance and exhaust sound quality in automobiles have been recognized as important factors, as they maximize the driving fun to fulfil the demands of customers. Therefore, many automobile manufacturers are studying various exhaust pipe shapes to improve sound quality and optimize exhaust pressure. The objective of the exhaust pipe design is to maximize the engine efficiency using optimal exhaust pressure settings. In this study, an exhaust system was fabricated with different junction shapes, and the results were analyzed through various experiments. The exhaust gas pressure acting inside the exhaust pipe was measured using a pressure transducer. Meanwhile, the vibration generated in the vehicle was measured in three axial directions and analyzed. The ground noise generated in the indoor and outdoor of the vehicle was measured, and the noise generated at the maximum output was measured and analyzed.

배관망의 비정상상태 압축성 유동해석을 위한 TVD 와 MOC 방법의 비교 연구 (Comparative study between TVD and MOC methods for the analysis of Unsteady compressible flow in pipe network)

  • 신영섭;사종엽
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2000년도 추계 학술대회논문집
    • /
    • pp.101-108
    • /
    • 2000
  • Pipe network analysis is analyze all of it about pressure and volume flow rate through that are pipeline, junction, regulator and valve etc. In this study is compare TVD with MOC method for analysis of unsteady compressible flow in pipelines. Then, we calculated unsteady compressible flow for pipe network that periodic volume flow rate conditions.

  • PDF