감육이 존재하고 내압을 받는 T 분기관의 한계하중 평가식

Limit Load Solutions for Piping Branch Junctions with local wall-thinning under Internal Pressure

  • 발행 : 2007.05.30

초록

The present work presents plastic limit load solutions for piping branch junctions with local wall-thinning, based on detailed three-dimensional (3-D) and small strain FE limit analyses using elastic-perfectly plastic materials. Three types of loading are considered; internal pressure, in-plane bending on the branch pipe and in-plane bending on the run pipe. The wall-tinning located on variable area of the piping branch junction is considered. A wide range of piping branch junction and wall-thinning geometries are considered. Comparison of the proposed solutions with FE results shows good agreement

키워드