• Title/Summary/Keyword: Pin to pin

Search Result 2,304, Processing Time 0.029 seconds

Chip Implementation of 830-Mb/s/pin Transceiver for LPDDR2 Memory Controller (LPDDR2 메모리 컨트롤러를 위한 830-Mb/s/pin 송수신기 칩 구현)

  • Jong-Hyeok, Lee;Chang-Min, Song;Young-Chan, Jang
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.659-670
    • /
    • 2022
  • An 830-Mb/s/pin transceiver for a controller supporting ×32 LPDDR2 memory is designed. The transmitter consists of eight unit circuits has an impedance in the range of 34Ω ∽ 240Ω, and its impedance is controlled by an impedance correction circuit. The transmitted DQS signal has a phase shifted by 90° compared to the DQ signals. In the receive operation, the read time calibration is performed by per-pin skew calibration and clock-domain crossing within a byte. The implemented transceiver for the LPDDR2 memory controller is designed by using a 55-nm process using a 1.2V supply voltage and has a maximum signal transmission rate of 830 Mb/s/pin. The area and power consumption of each lane are 0.664 mm2 and 22.3 mW, respectively.

Experimental Study on the Friction Characteristics of Pin-Bush Bearing Metals for Diesel Engine (디젤엔진용 핀부시 베어링 소재의 마찰특성에 관한 실험적 연구)

  • Kim, Chung-Kyun;Kim, Kyung-Seob
    • Tribology and Lubricants
    • /
    • v.25 no.6
    • /
    • pp.409-413
    • /
    • 2009
  • This paper presents the hardness and friction characteristics of pb-free pin-bush bearing metal, which is manufactured by a centrifugal casting technology. A bronze metal with a high hardness and low friction properties is usually used for Diesel engine pin-bush bearing and high pressure cylinder. Pb-free metal for pin-bush bearings shows a little high hardness of 120 Hv compared with that of a conventional Pb bearing metal of 100~110 Hv. In general, the friction coefficient of pin-bush bearings is affected by a rotating speed and a load for various rubbing contact modes. But a contact load is more influential parameter when the contact rubbing mode transits from a mixed lubrication to a dry friction contact. The experimental result shows that the friction coefficient is more unstable at the dry contact mode compared with that of other two rubbing modes such as oil film contact and mixed friction conditions.

Design and Fabrication of InP/InGaAs PIN Photodiode for Horizontally Integrated OEIC's (수평집적형 광전자집적회로를 위한 InP/InGaAs PIN 광다이오드의 설계 및 제작)

  • 여주천;김성준
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.4
    • /
    • pp.38-48
    • /
    • 1992
  • OEIC(Optoelectronic Integrated Circuit)'s can be integrated horizontally or vertically. Horizontal integration approach is, however, more immune to parasitic and more universally applicable. In this paper, a structural modeling, fabrication and characterization of PIN photodiodes which can be used in the horizontal integration are performed. For device modeling, we build a transmission line model from 2-D device simulation, from which lumped model parameters are extracted. The speed limits of the PIN photodiodes can also be calculated under various structural conditions from the model. Thus optimum design of horizontally integrated PIN photodiodes for high speed operation are possible. Such InGaAs/InP PIN photodiodes for long-wavelength communications are fabricated using pit etch, epi growth, planarization, diffusion and metallization processes. Planarization process using both RIE and wet etching and diffusion process using evaporated Zn$_{3}P_{2}$ film are developed. Characterization of the fabricated devices is performed through C-V and I-V measurements. At a reserve bias of 10V, the dark current is less than 5nA and capacitance is about 0.4pF. The calculated bandwidth using the measured series resistance and capacitance is about 4.23GHz.

  • PDF

Mixed reality visualization in shoulder arthroplasty: is it better than traditional preoperative planning software?

  • Sejla Abdic;Nicholas J. Van Osch;Daniel G. Langohr;James A. Johnson;George S. Athwal
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.2
    • /
    • pp.117-125
    • /
    • 2023
  • Background: Preoperative traditional software planning (TSP) is a method used to assist surgeons with implant selection and glenoid guide-pin insertion in shoulder arthroplasty. Mixed reality (MR) is a new technology that uses digital holograms of the preoperative plan and guide-pin trajectory projected into the operative field. The purpose of this study was to compare TSP to MR in a simulated surgical environment involving insertion of guide-pins into models of severely deformed glenoids. Methods: Eight surgeons inserted guide-pins into eight randomized three-dimensional-printed severely eroded glenoid models in a simulated surgical environment using either TSP or MR. In total, 128 glenoid models were used and statistically compared. The outcomes compared between techniques included procedural time, difference in guide-pin start point, difference in version and inclination, and surgeon confidence via a confidence rating scale. Results: When comparing traditional preoperative software planning to MR visualization as techniques to assist surgeons in glenoid guide pin insertion, there were no statistically significant differences in terms of mean procedure time (P=0.634), glenoid start-point (TSP=2.2±0.2 mm, MR=2.1±0.1 mm; P=0.760), guide-pin orientation (P=0.586), or confidence rating score (P=0.850). Conclusions: The results demonstrate that there were no significant differences between traditional preoperative software planning and MR visualization for guide-pin placement into models of eroded glenoids. A perceived benefit of MR is the real-time intraoperative visibility of the surgical plan and the patient's anatomy; however, this did not translate into decreased procedural time or improved guide-pin position.

Design of Reconfigurable Dual Polarization Patch Array Antenna (재구성 이중편파 패치 배열 안테나 설계)

  • Won Jun Lee;Young Jik Cha
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.463-468
    • /
    • 2023
  • In this paper, we proposed reconfigurable dual polarization patch array antenna that can select two polarizations(Vertical, RHCP) using defected ground structure and Pin diode. The proposed antenna was designed arranging a circular polarization patch antenna implemented with a square microstrip patch and two slots 3x3 at 25.8mm placed, a half-wavelength of 5.8 GHz. Conect the pin diode and the capacitor to the slot diagonally placed on the ground of each antennas, and select polarization using the open/short operating according to the application of DC voltage to the pin diode. As a result of the design, the gain of the antenna is 11.7 dBi at vertical polarization and 11.6 dBic at RHCP. The axial ratio is 20.3 dB at 1.8 dB vertical polarization at RHCP. Mutual Coupling is Maximum to -20.8 dB for vertical polarization and Maximum to -30.1 dB for RHCP.

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF

Observation of Dynamic Movement of Probing Pin on PCB Pad Using Electrical Reliability Test (인쇄회로 기판의 전기검사에서의 미세 탐침과 패드의 동적 거동 현상 관측)

  • Song, Seongmin;Cha, Gangil;Kim, Myungkyu;Jeon, Seungho;Yu, SangSeok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.245-251
    • /
    • 2015
  • In an electrical reliability test of a printed circuit board (PCB), the impact of the micro probing pins on the PCB needs to be checked to ascertain the quality of the circuit. In this study, the impact of the dynamic movement of the probing pin on the pad was observed. As a misaligned pin can exert horizontal force on the pad of the PCB, this study focused on the behavior of a misaligned probing pin. The parameters of observation were the circular and flat edges of the probing pin. The effects of the speed of movement, diameter, and the length of projection of the probing pin were also investigated. The results demonstrated that slippage angle is strongly affected by the shape of the edge of the probing pin, and that projection length is an important factor affecting pin slippage. In contrast, the speed of movement of the probing pin was able to double the slippage angle.

Characteristics of Microwelded BLU CCFL Electrode in Terms of Glass Beading Heat Treatment Temperature (미세 용접된 BLU CCFL 전극의 유리비딩 열처리 온도에 따른 접합부 특성)

  • Kim, Gwang-Soo;Kim, Sang-Duck;Kwon, Hyuk-Dong
    • Journal of Welding and Joining
    • /
    • v.27 no.4
    • /
    • pp.73-78
    • /
    • 2009
  • Characterization of the microweld CCFL electrode for the TFT-LCD backlight unit was carried out in terms of the glass beading heat treatment conditions. We evaluate the weld zone and parent metal of the microweld CCFL electrodes that were exposed to simulated glass beading heat treatment. The CCFL electrode was composed of the cup made with pure Ni, the pin made with pure Mo and the lead wire made with Ni-Mn alloy. Each part of the electrode was assembled together by micro spot welding process and then the assembled electrodes were exposed to simulated glass beading temperatures of $700^{\circ}C,\;750^{\circ}C$ and $800^{\circ}C$. The microstructures of the microweld CCFL electrode were observed by using optical microscope, scanning electron microscope and EDS. Micro-tensile and microhardness test were also carried out. The results indicated that the grain coarsening in the HAZs(heat affected zones) for both the cup-pin weld and pin-lead wire were exhibited and the grain coarsening of the HAZ for the cup and the lead wire was more obvious than the HAZ of the pin. The micro-tensile test revealed that the fracture occurred at the cup-pin weld zone for all test conditions. The fracture surface could be classified into two parts such as pin portion and cup portion including weld nugget. The failure was seemed to be initiated from the boundary between nugget and pin through the weld joint. The result of the microhardness measurement exhibited that the relatively low hardness value, about 105HV was recorded at the HAZ of the cup. This value was about 50% less than that of the original value of the cup. The reduction of the microhardness was considered as the cause of the grain coarsening due to welding process. It was also appeared that there was no change in electric resistance for the standard electrodes and heat treated electrodes.

Estimation of Indent Fracture due to the Moving Process of a Pin on PCB Plate (PCB 판에 대한 핀의 이동 공정에 따른 압입파괴 평가)

  • Kim, Young-Choon;Kim, Choon-Sik;Lee, Hee-Sung;Cho, Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.6967-6972
    • /
    • 2014
  • Assembly using a bolt and nut, and rivet or pin have been used widely for forming mechanical joints. The indent method is an easier process than other manufacturing techniques and the toughness of the material is excellent. On the other hand, there are many cases in which the cracks occur on the manufacturing process as the indent method. Therefore, two kinds of models, in which a pin goes into and out PCB plate in this study were developed using the CATIA program and finite element methods were performed using the ANSYS program. When a pin was passed through a PCB plate in cases 1 and 2, the maximum loads applied to the PCB plate were 79.708N and 90.277N, respectively. When the PCB plate came out of the pin in cases 1 and 2, the maximum loads were 63.783N and 33.75N, respectively. The damage prevention and durability can be improved by applying the study results to the design of real indentation.

Characterization of [011] Poled Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystals by Resonance Method (공진법 기반의 [011] 분극 Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 압전단결정 물성규명)

  • Je, Yub;Sim, Min Seop;Cho, Yohan;Lee, Wonok;Lee, Sanggoo;Lee, Jeong Min;Seo, Hee Seon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.6
    • /
    • pp.466-474
    • /
    • 2021
  • [011] poled ternary Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 (PIN-PMN-PT) single crystals have been investigated for active materials for acoustic transducers because of their high piezoelectric properties in both shear and transverse modes. In order to use [011] poled PIN-PMN-PT single crystals for acoustic transducers, the characterization of full-matrix material properties is required. In this study, full sets of compliance, dielectric, and piezoelectric constants of [011] poled rhombohedral PIN-PMN-PT were measured by a resonance method. Dimensions and geometries of 12 samples were proposed for measuring 17 independent material constants of [011] poled rhombohedral PIN-PMN-PT single crystals. Two sets of samples with different PT concentrations, 0.24PIN-0.49PMN-0.27PT and 0.24PIN-0.46PMN-0.30PT, were fabricated and their material properties were measured. Measured impedance spectra and simulated impedance spectra of the samples were compared to check the accuracy of the measurements.