• 제목/요약/키워드: Pile loading capacity

검색결과 185건 처리시간 0.034초

H-pile의 지지력 특성 및 동역학적 공식의 신뢰도 평가 (Characteristics of Bearing Capacity and Reliability-based Evaluation of Pile-Driving Formulas for H Pile)

  • 오세욱;이준대
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.81-88
    • /
    • 2003
  • Recently, pile foundations were constructed in rough or soft ground than ground of well condition thus it is important that prediction of ultimate bearing capacity and calculation of proper safety factor applied pile foundation design. This study were performed to dynamic loading tests for the thirty two piles at four different construction sites and selected pile at three site were performed to static loading tests and then compare with measured value and value of static and dynamic loading tests. The load-settlement curve form the dynamic loading tests by CAPWAP was very similar to the results obtained from the static load tests. Based on dynamic and static loading tests, the reliability of pile-driving formula were analyzed and then suggested with proper safety factor for prediction of allowable bearing capacity in this paper.

양방향말뚝재하시험의 재하용량 기준 설정을 위한 사례분석 연구 (A study on case analysis for loading capacity standard establishment of bi-directional pile load test (BD PLT))

  • 최용규;서정혜;김상일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.377-384
    • /
    • 2008
  • In the bi-directional pile load test (BD PLT) for pile load test of Mega foundation, loading capacity specification were not specified exactly. Therefore there are so many confusions and variations of maximum 2 times in loading capacity are come out. In this study, specifications of bi-directional pile load test (BD PLT) were considered. Based on cases of the bi-directional pile load test performed in domestic areas, maximum equivalent test load, test load increasing ratio and sufficiency ratio of design load were analyzed. It can be known that the loading capacity specification of bi-directional pile load test must be defined as 1-directional test load that is established as more than 2 times of design load.

  • PDF

동재하시험에 의한 모래자갈층에 근입된 매입말뚝의 지지력 산정 (The Estimation of Bearing Capacity of Auger-drilled Pile in Sand-Gravel by Dynamic Load Test)

  • 최기철;문유호;오원근;천병식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1819-1826
    • /
    • 2007
  • This study results of performed field load test in order to estimate the best pile length assessment and allowable bearing capacity of the pile foundation. End of initial driving(EOID) and restrike of pile dynamic loading tests were performed to calculate allowable bearing capacity of the experimental pile side and results were compared with the allowable bearing capacity estimated by theory. The results of allowable bearing capacity by EOID test is $1.08{\sim}1.21$ in the range of compared to the capacity calculated by the Structure Foundation Design Criterion. Allowable bearing Capacity by restrike of pile dynamic loading test is $1.32{\sim}1.48$ in the range of compared to the Structure Foundation Design Criterion. The Foundation Design Criterion underestimated the pile capacity. If the bearing capacity calculated by Structure Foundation Design Criterion is 100, EOID of pile dynamic loading test is 116, restrike of pile dynamic loading test is 138 for 20m pile used in this experimental.

  • PDF

양방향말뚝재하시험의 재하용량 기준에 관한 연구 (A Study on the Loading Capacity Standard of Bi-directional Pile Load Test (BD PLT))

  • 최용규
    • 대한토목학회논문집
    • /
    • 제28권6C호
    • /
    • pp.379-388
    • /
    • 2008
  • 대형말뚝기초의 양방향 재하시험에서 재하용량 기준이 정확하게 규정되어 있지 않다. 그래서 양방향말뚝재하시험을 수행함에 있어 많은 혼란이 발생하고 있으며 재하용량에서 최대 2배까지의 차이가 나타나고 있다. 본 연구에서는 양방향 말뚝재하시험 기준들을 고찰하였으며, 국내에서 수행된 양방향 말뚝재하시험 사례들에 기초하여 최대등가시험하중, 재하하중 증가비, 재하용량 증가비 및 설계하중 충족비를 분석하였다. 양방향 말뚝재하시험 기준은 1방향 재하용량으로 정의되어야 하며, 1방향 재하용량은 설계하중의 2배 이상 이어야 한다는 것을 알 수 있었다.

유한차분법을 이용한 말뚝의 하중전이특성 및 해석기법 (Analytical Technique and Load Transfer Features on Pile Using Finite Difference Method)

  • 한중근;이재호
    • 한국환경복원기술학회지
    • /
    • 제9권5호
    • /
    • pp.10-21
    • /
    • 2006
  • For analyze of the bearing capacity, skin friction and settlements of pile on axial compressive loading, both Load transfer tests of pile and pile loading test in field have application to commonly before pile installing. A bearing capacity of pile was affected by the characteristics of surrounding ground of pile. Especially, that is very different because of evaluation of settlement due to each soil conditions of ground depths. The ground characteristics using evaluation of bearing capacity of pile through load transfer analysis depends on N values of SPT, and then a bearing capacity of pile installed soft ground and refilled area may be difficult to rational evaluation. An evaluation of bearing capacity on pile applied axial compressive loading was effected by strength of ground installed pile, unconfined compressive strength at pile tip, pile diameter, rough of excavated surface, confining pressure and deformation modules of rock etc and these are commonly including the unreliability due to slime occurred excavation works. Load transfer characteristics considered ground conditions take charge of load transfer of large diameter pile was investigated through case study applied load transfer tests. To these, matrix analytical technique of load transfer using finite differential equation developed and compared with the results of pile load test.

침하량과 압축량을 고려한 말뚝의 설계법 개발을 위한 연구 (A Study for the Development of Pile Design Method Considering Settlement and Compression)

  • 임종석;하혁;정상균
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1287-1294
    • /
    • 2006
  • A pile is compressed with settlements when loading and bearing capacity is altered along relative displacement of pile/soil on settlement and compression. Settlements of pile displaying limit skin friction is different from displaying tip resistance. Therefore, it is an error in traditional method that bearing capacity of pile is estimated from the sum of limit skin fraction and tip resistance. Accordingly, development of design method considering behavior of load-settlement is needed. In this study, we would like to establish the base for development of design method considering bearing capacity altering along displacement on settlement and compression. For this, we established system and substance of design method. And in order to establish relationship of load-settlement of pile on the type of soil, we analyzed and arranged existing database and pile loading test. On design method, settlement is assumed gradually on each capacity level being assumed gradually. Bearing capacity developing on the pile is obtained on each settlement level. Until the obtained bearing capacity will be equal to assumed capacity, this process is continued with increasing settlement. Load-settlement curve for soil classification is sketched in the process computing settlement on assumed capacity. This design method will be materialized by computation program.

  • PDF

모래지반에서 반복수평하중을 받는 항타말뚝의 거동 (Behavior of Laterally Cyclic Loaded Piles Driven into Sand)

  • 백규호;박원우;김영준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.913-922
    • /
    • 2009
  • Fourteen model pile load tests using a calibration chamber and instrumented model pile were preformed to investigate the variation of the behaviors of driven piles in sands with soil and lateral cyclic loading conditions. Results of the model tests showed that the first loading cycle generated more than 70% of the pile head rotation developed for 50 lateral loading cycles. Lateral cyclic loading also made an increase of the ultimate lateral load capacity of piles for $K_0$=0.4 and an decrease for $K_0$ higher than 0.4. Higher portion of the increase or decrease in the ultimate lateral load capacity by lateral cyclic loading was generated for the first loading cycle due to densification of loosening of the soil around the pile by lateral cyclic loading. It was also observed that a two-way cyclic loading caused higher ultimate lateral load capacity of driven piles than a one-way cyclic loading. When the pile was in the ultimate state, the maximum bending moment developed in the pile increased with increasing $K_0$ value of soil and was insensitive to the magnitude and number of lateral cyclic loading.

  • PDF

모래지반에 매입된 날개없는 석션앵커의 인발력에 대한 원심모형실험 (Centrifuge Model Tests on the Pullout Capacity of Embedded Suction Anchor without Flanges in Sand layer)

  • 김경오;김유석;고부현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.517-520
    • /
    • 2005
  • The embedded suction anchor(ESA) is and anchor that is driven by a suction pile. The cross-sectional shape of the ESA anchor is circle. Its diameter is the same as that of the suction pile that is used to drive it into the seafloor. For the installation, the anchor is attached to the tip of the suction pile and then driven as a unit with the pile by and applied suction pressure. Once the ESA anchor reaches the desired depth, the pile is retrieved by applying a positive pressure. Finally, only the ESA anchor remains in the soil layer. This paper presents the results of centrifuge model tests to investigate ESA pullout capacity. The main parameters that have effects on the pullout capacity of ESA may include g-level, embedded depth, direction of loading, and loading point. The results of tests show that the pullout loading capacities increase as the loading point shift toward the tip of the anchors for a given loading direction. They also indicate that the loading point associated with the maximum pullout loading capacity is located at approximately 67 percent of the anchor length from the top for the horizontal load.

  • PDF

단일말뚝 형태의 모형시험을 통한 SCP와 GCP의 극한지지력 비교 (Comparison of Bearing Capacity between SCP and GCP by Unit Cell Model Tests)

  • 김병일;이승원;김범상;유완규
    • 한국지반공학회논문집
    • /
    • 제20권8호
    • /
    • pp.41-48
    • /
    • 2004
  • 이 연구에서는 아직 국내에서는 시공실적이 없는 쇄석다짐말뚝(Gravel Compaction pile)공법의 적용성을 판단하기 위하여 SCP와 GCP의 모형토조시험을 수행하였다. 즉, 원통형 압밀상자(지름 20cm, 높이 40cm)에 치환율 30, 40, 50, 60, 70%로 달리 조성하여 원심력 압밀시험기를 이용하여 압밀시킨 후, 재하시험을 통하여 두 공법의 지지력 특성을 비교 검토하였다. 또한 모형시험을 통해 얻어진 극한지지력을 기존에 제안된 SCP 및 GCP 시공지반의 극한지지력 산정식을 이용한 계산값과 비교하였다. 모형시험 결과 GCP 시공지반이 SCP 시공지반에 비해 지지력 측면에서 더 우수한 것으로 나타났다.

모래지반에 근입된 석션파일의 인발저항력 및 변위거동 분석 (Analysis of Load Capacity and Deformation Behavior of Suction Pile Installed in Sand)

  • 김유석;장연수
    • 한국지반공학회논문집
    • /
    • 제27권11호
    • /
    • pp.27-37
    • /
    • 2011
  • 모래지반에서 석션파일의 최대인발저항력 산정을 위한 일련의 원심모형실험이 수행되었다. 최대인발저항력 산정을 위한 실험인자인 석션파일의 인발각과 인발작용점의 위치에 대하여 실험을 수행하였다. 인발작용점의 경우 75%에서 최대인발저항력이 관찰되었다. 모든 경사각에 대하여 전체파일 높이에서 50%에서 75%사이에 석션파일의 회전각이 변함을 알 수 있었다. 인발각이 증가함에 따라 최대 인발저항력 발생 시까지의 변위가 점점 작아짐을 알 수 있었다. 석션파일의 형상중심의 수직변위를 최대인발저항력이 작용한 시점에서 관찰한 결과 모두 지표 쪽으로 이동한 것을 알 수 있었다.