• 제목/요약/키워드: Piezo stack

검색결과 33건 처리시간 0.03초

작동 연료온도가 Bypass type 피에조 인젝터의 분사 특성에 미치는 영향 (Effects of Working Fuel Temperature on Injection Characteristics of Bypass Type Piezo Injector)

  • 조인수;이진욱
    • 한국분무공학회지
    • /
    • 제24권2호
    • /
    • pp.66-72
    • /
    • 2019
  • Diesel vehicles suffer from poor starting and running problems at cold temperatures. Diesel vehicles have the characteristic that CO and PM are reduced or similarly discharged when going from low temperature to high temperature. In this study, a bypass type piezo injector for electronic control based common rail injection system was used. Numerical analysis using injector drive analysis model was performed to analyze injector drive and internal fuel flow characteristics according to fuel temperature change. The results show that the rate of density change due to the fuel temperature is proportional, and that the effect of the kinematic viscosity is relatively large between $-20^{\circ}C$ and $0^{\circ}C$. Comparing the results of temperature condition at $0^{\circ}C$ and $20^{\circ}C$, it is considered that the viscosity is more correlated with the needle displacement than the pressure chamber of the delivery chamber.

차세대 고응답 분사용 피에조 인젝터의 노즐유동 및 분무특성에 관한 연구 (A Study on Nozzle Flow and Spray Characteristics of Piezo Injector for Next Generation High Response Injection)

  • 이진욱;민경덕
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.553-559
    • /
    • 2006
  • Most diesel injector, which is currently used in high-pressure common rail fuel injection system of diesel engine, is driven by the solenoid coil energy for its needle movement. The main disadvantage of this solenoid-driven injector is a high power consumption, high power loss through solenoid coil and relatively fixed needle response's problem. In this study, a prototype piezo-driven injector, as a new injector mechanism driven by piezoelectric energy based on the concept of inverse piezo-electric effect, has been designed and fabricated to know the effect of piezo-driven injection processes on the diesel spray structure and internal nozzle flow. Firstly we investigated the spray characteristics in a constant volume chamber pressurized by nitrogen gas using the back diffusion light illumination method for high-speed temporal photography and also analyzed the inside nozzle flow by a fully transient simulation with cavitation model using VOF(volume of fraction) method. The numerical calculation has been performed to simulate the cavitating flow of 3-dimensional real size single hole nozzle along the injection duration. Results were compared between a conventional solenoid-driven injector and piezo-driven injector, both equipped with the same micro-sac multi-hole injection nozzle. The experimental results show that the piezo-driven injector has short injection delay and a faster spray development and produces higher injection velocity than the solenoid-driven injector. And the predicted simulation results with the degree of cavitation's generation inside nozzle for faster needle response In a piezo-driven injector were reflected to spray development in agreement with the experimental spray images.

AMESim기반 CRDi용 인젝터의 2단분사 동적거동 특성해석 (Analysis of Dynamic Characteristics in Two-stage Injection for CRDi Injectors Based on AMESim Environment)

  • 조인수;권지원;이진욱
    • 한국분무공학회지
    • /
    • 제17권2호
    • /
    • pp.57-63
    • /
    • 2012
  • For reduction of CO, NOx and soot emission emitted by diesel diffusion combustion, the authors focused on injection actuator to improve fuel availability inside combustion chamber. In this study, it was investigated the internal dynamic characteristics of two-stage injection with diesel injectors with different driving type for the common rail direct injection by using the AMESim simulation code. The analysis parameter defined such as fuel pressure, injection hole's diameter and driven voltage. As the results, it was shown that the piezo-driven injector had a faster response and had better control capability than the solenoid-driven injector. It was found the piezo-driven injector can be utilized effectively as multiple injector than solenoid-driven injector.

4절링크 기구기반의 회전형 초정밀위치결정기구의 개발 (Development of Rotational Nanoactuator Based on Four-Bar Linkage)

  • 정영훈
    • 한국생산제조학회지
    • /
    • 제23권4호
    • /
    • pp.361-367
    • /
    • 2014
  • Ultra-precision positioning plays a crucial role in emerging technologies such as electronics, bioengineering, optics, and various nanofabrication technologies. As a result, various nanopositioning methods have been presented. In particular, nanopositioning using a flexure mechanism and piezo-electric actuator is one of the most valuable methods because of its friction-free motion and subnanometer-scale motion resolution. In this study, a rotational nanoactuator based on a right-circular flexure mechanism and piezo-electric actuator was developed through a consideration of the kinematics and structural deformation. An experimental setup was constructed to verify the performance expectation. Consequently, it was demonstrated that the developed system had a maximum rotational angle of about 0.01 rad, as well as sufficient linearity with respect to the input voltage.

Detection of the mechanical resonance of a micromechanical cantilever using dynamic flexural measurement technique and its mass sensing application

  • 김학성;윤호열;정운석;유나리;박정호;이상욱
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.447-447
    • /
    • 2011
  • We studied to detect the mass variation using micro mechanical resonator. For measuring the resonance frequency of the micro mechanical system, optical method using laser interference is selected. A simple resonator is prepared by attaching an AFM cantilever on the piezo stack. The piezo stack makes a the cantilever vibrated with its resonance frequency. To change the mass of the resonator, gold was evaporated on the cantilever. We measured how much resonance frequency was changed according to the amount of gold attached on cantilever. This resonator is able to perform the role of a mass sensor and has a resolution of the order of micrograms. The fabrication of the resonator and measurement setup for detecting the mechanical resonance will be introduced in this presentation.

  • PDF

함정용 능동 하이브리드 마운트 개발에 대한 연구 (A Study on Development of an Active Hybrid Mount for Naval Ships)

  • 문석준;지용진;윤정식;최승복;이현엽;김재호;정우진
    • 대한조선학회논문집
    • /
    • 제45권3호
    • /
    • pp.288-295
    • /
    • 2008
  • Passive-type control devices such as resilient mounts and wire rope isolators are generally used for protecting the shipboard equipment from shock loading and for suppressing the mechanical vibration of the equipment in naval ships. To improve the performance of the control device, a new hybrid mount is under development in this study. This mount consists of a passive-type rubber element and an active-type piezo-stack element. It can be expected that the mount has enhanced performance of about 20 dB or more with respect to transmissibility through a series of performance tests of prototype mount.

3차원 미세형상 측정용 탄성힌지 기반 압전구동식 격자 스캐너 (A Piezo-Driven Grating Scanner Based on Flexure Hinges for Measuring 3-Dimensional Microscopic Surface)

  • 최기봉;턴 알렉세이 대성;이재종;김성현;고국원;권순기
    • 제어로봇시스템학회논문지
    • /
    • 제15권8호
    • /
    • pp.798-803
    • /
    • 2009
  • This paper proposes a grating scanner which is driven by a stack-type piezoelectric element. The mechanism of the grating scanner is based on flexure hinges. Using some constraints, the compliant mechanism is designed and then verified by Finite Element Analysis. The designed compliant mechanism is manufactured by wire electro-discharge machining, and then integrated with a stack-type piezoelectric element for actuation and a capacitance displacement sensor for measuring ultra-precision displacement. Experiments demonstrates the characteristics and the performances of the grating scanner using the terms of working range, resonance frequency, bandwidth and resolution. The grating scanner is applicable to a Moire interferometry for measuring 3-dimensional microscopic surface.

Experimental Study on the Performance of a Bidirectional Hybrid Piezoelectric-Hydraulic Actuator

  • Jin, Xiao Long;Ha, Ngoc San;Li, Yong Zhe;Goo, Nam Seo;Woo, Jangmi;Ko, Han Seo;Kim, Tae Heun;Lee, Chang Seop
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권4호
    • /
    • pp.520-528
    • /
    • 2015
  • The piezoelectric-hydraulic actuator is a hybrid device that consists of a hydraulic pump driven by a piezo-stack coupled to a conventional hydraulic cylinder. The actuator is of compact size, but can produce a moderate energy output. Such hybrid actuators are currently being researched and developed in many industrialized countries due to the requirement for high performance and compact flight systems. In a previous study, we designed and manufactured a unidirectional hybrid actuator. However, the blocking force was not as high as expected. Therefore, in this study, we redesigned the pump chamber and hydraulic cylinder and also improved the system by removing the air bubbles. Two different types of piezo-stacks were used. In order to achieve bidirectional capabilities in the actuator, commercial solenoid valves were used to control the direction of the output cylinder. Experimental testing of the actuator in unidirectional and bidirectional modes was performed to examine performance issues related to driving frequency, bias pressure, reed valve thickness, etc. The results showed that the maximum blocking force was measured as 970.2N when the frequency was 185Hz.