• Title/Summary/Keyword: Picture Quality

Search Result 506, Processing Time 0.023 seconds

Error Concealment Using Gradient Vectors in H.264 Decoder (H.264 디코더에서 기울기 벡터를 이용한 에러복원 방법)

  • Jeon Sung-Hoon;Yoo Jae-Myeong;Lee Guee-Sang
    • The KIPS Transactions:PartB
    • /
    • v.13B no.3 s.106
    • /
    • pp.197-204
    • /
    • 2006
  • Recent advances in information technology have resulted in rapid growth in the mobile communication. With this explosive growth, reliable transmission and error concealment technique become increasingly important to offer high quality multimedia services. In this paper, we propose an improved BMA(Boundary Matching Algorithm) method using gradient vectors to conceal channel errors in inter-frames of H.264 video images. General BMA method computes the sum of pixel differences of adjacent pixels of the candidate block and its neighbouring blocks, assuming that adjacent pixels have almost the same value. In real images, however, there exist some gradients, which means that the pixel values are increasing or decreasing in a specific direction. In this paper, we develop a precise estimation method of errors in candidates blocks using gradient information and try to recover lost blocks with this technique. Experimental results show the improvement of picture quality about $1{\sim}3dB$ compared to existing methods.

Splicing Techniques in the PES System Layer for the Editing at a GOP Module of The MPEG-2 based Images (MPEG-2 기반영상 GOP 단위 편집을 위한 PES 시스템 영역에서의 스트림 접함 방법)

  • 김동준;최윤식
    • Journal of Broadcast Engineering
    • /
    • v.7 no.4
    • /
    • pp.355-361
    • /
    • 2002
  • In this paper, several methods which guarantee the seamless editing when the splicing is applied to the MPEG-2 system streams are described. In the MPEG-2 system standard, it is recommended that the splicing technique is applied in the Transport Stream(TS) domain. However, in view of the video editing, the splicing at an arbitrary picture unit can not be guaranteed. The splicing in the PES domain is only considered in this paper because the PES is one of the MPEG-2 system streams and this result could be directly extended to the video splicing techniques in the TS or PS domain. Thus. the problems that might occur when different two PES streams are spliced and its effects to the video quality are compared and analyzed. Based on this analysis. several methods that can resolve these problems directly in the PES domain are proposed. Consequently, the computer simulation demonstrates that the splicing at a GOP modulo is guaranteed to have good video quality even without considering the state of the PES packet only if the PES_packet_length field of the PES packet header is used.

Analysis of the Dental Implants MRI Artifacts by Using the ACR Phantom (ACR 팬텀을 이용한 치아 임플란트 자기공명영상 인공물 분석)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.629-635
    • /
    • 2016
  • ACR phantom for quality control of magnetic resonance imaging equipment can evaluate magnetic resonance imaging picture quality through various structures within the phantom. In this study, percent Signal Ghosting and Slice position accuracy of imaging could be analyzed by attaching implant and the wire for correction of tooth using ACR phantom in Head coil of 3.0T equipment. In the T1 weighted imaging of the first slice and the eleventh slice of implant, the slice position accuracy appeared to be good in ingress bandwidth 300, and it was good in ingress bandwidth 130 when wire for correction was attached. Percent Signal Ghosting in the seventh slice of SE T1 weighted imaging, implant and wire for correction added all appeared to be good when ingress bandwidth was 230. It is thought that in case of implant dental prosthesis patients in brain exam using magnetic resonance imaging, optimum image can be obtained by changing ingress bandwidth.

Analysis on DTV Indoor Reception Environments (디지털 TV 실내수신 환경 분석)

  • Suh, Young-Woo;You, Ho-Jin;Park, Min-Ho;Park, Joon-Sung;Kim, Gyu-Young;Seo, Jong-Soo
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.636-650
    • /
    • 2008
  • DTV has a great advantage as compared to Analog TV in picture quality under low reception field strength. Various high quality tuners have been developed to result in much smaller Noise Figure of the receivers and many trials for receiving DTV signal through indoor antenna. In this paper, results of intensive field tests on the indoor reception of DTV are presented. Tests were carried out around Seoul-Gyeonggi Metropolitan area. Commercial directional and omni-directional antennas and 5th generation receiver were used for reception availability tests. The effects of heights, locations, and types of the house as well as the distance to the transmitter on the reception performances are analyzed. Our test results will be applied to improve the indoor reception environment of DTV.

A Study on Decoding Characteristic Analysis of Non-iterative Fractal Image Compression (무반복 프랙탈 영상 압축의 복호 특성 분석에 관한 연구)

  • Kwak No-Yoon
    • Journal of Digital Contents Society
    • /
    • v.5 no.3
    • /
    • pp.199-204
    • /
    • 2004
  • A problem of many fractal image compression algorithms providing good quality at low bit rate is that the decoding time rests on an iterative procedure whose complexity is imag-dependent. This paper proposes an iterative-free fractal image decoding algorithm to reduce the decoding time. In the proposed method, under the encoder previously with the same codebook image as an initial image to be used at the decoder, the fractal coefficients are obtained through calculating the similarity between the codebook image and an input image to be encoded. As the decoding time could be remarkably reduced. For verifying the validity and universality of proposed method, We evaluated and analyzed the performance of decoding time and image quality for a number of still images and a moving picture with different distributed characteristics.

  • PDF

Design and Implementation of CDA Based PACS for Optimized Metadata Extraction (최적화된 메타데이터 추출물 위한 CDA 기반의 의료영상전달시스템 설계 및 구현)

  • Kim Sun-Chil;Cho Hune;Kwak Yun-Sik;Kim Il-Kon;Kim Hwa-Sun
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.5
    • /
    • pp.315-323
    • /
    • 2005
  • The recent development of embodiment technology of the medical images makes most medical institutions introduce PACS in haste. However, while many older HIS and PACS systems are not yet capable of some of the integration, several new systems are moving rapidly in that direction. Typical PACS system architecture begins with the HIS since this is where the correct patient demographic information and in many cases the orders originate. So, PACS developed convenience of users and to satisfy user's demand because of financial limitations and administrator-oriented considerations in the process of development. Therefore, we have developed a CDA (Clinical Document Architecture) based PACS with HIS, by which we can search and refer to the patient's medical images and information with few restrictions of time and space for diagnosis and treatment. Target model of this research limited to 135 of hospital have 200 beds. We'll make more effort to develop the application which insures the better quality and information of medical images. Medical Image History manages the patient's image files and various medical informations like film chart in connection with time. This trial will contribute to the reduction of the financial loss caused by unnecessary devices and improve the quality in the medical services. The demand on the development of the program which refers to the medical data quickly and keeps them stable will be continued by the medical institute. This will satisfy the client's demand and improve the service to the patients in that the program will be modified from the standpoint of the users.

The Improved Deblocking Filter for Low-bit Rate H.264/AVC Video (저해상도 H.264/AVC 비디오를 위한 개선된 디블럭킹 필터)

  • Kwon, Dong-Jin;Ryu, Sung-Pil;Kwak, Nae-Joung;Ahn, Jae-Hyeong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.2
    • /
    • pp.284-289
    • /
    • 2008
  • H.264/AVC among moving picture compression standard is the standard format for high compression rate and reliable video transimission. It generates blocking effects in video due to compressing video using block-based DCT and includes de-blocking filter to reduce blocking effect. Therefore, the filter makes the video over-smoothing and the quality of it is reduced. In this paper, we propose a improved de-blocking filter to solve the demerit. The proposed de-blocking filter redetermine the block boundary strength and apply the comer filtering to eliminate artifacts in low frequency domain. To evaluate the performance, we apply the proposed deblocking filter and exiting method to various video and evaluated the quality of image subjectively and objectively by analyzing the result. The simulation result shows the proposed method preserves the edge of video, reduces blocking effects and improves PSNR than the existing method.

Fast Motion Estimation Using Multiple Reference Pictures In H.264/Avc (H.264/AVC에서 다중 참조 픽처를 이용한 고속 움직임 추정)

  • Kim, Seong-Hee;Oh, Jeong-Su
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5C
    • /
    • pp.536-541
    • /
    • 2007
  • In video coding standard H.264/AVC, motion estimation using multiple reference pictures improves compression efficiency but the efficiency depends upon image content not the number of reference pictures. So, the motion estimation includes a large amount of computation of no worth according to image. This paper proposes fast motion estimation algorithm that removes worthless computation in the motion estimation using multiple reference pictures. The proposed algorithm classifies a block into valid and invalid blocks for the multiple reference pictures and removes the workless computation by applying a single reference picture to the invalid block. To estimate the proposed algorithm's performance, image quality, bit rate, and motion estimation time are compared with ones of the conventional algorithm in the reference software JM 9.5. The simulation results show that the proposed algorithm can considerably save about 38.67% the averaged motion estimation time while keeping the image quality and the bit rate, whose are average values are -0.02dB and -0.77% respectively, as good as the conventional algorithm.

Compression of 3D color integral images using 2D referencing technique (2차원 참조 기법을 이용한 3D 컬러 집적 영상의 압축)

  • Kim, Jong-Ho;Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2693-2700
    • /
    • 2009
  • This paper proposes an effective compression method to utilize the 3D integral image with large amount of data obtained by a lens array in various applications. The conventional compression methods for still images exhibit low performance in terms of coding efficiency and visual quality, since they cannot remove the correlation between elemental images. In the moving picture compression methods, 1D scanning techniques that produce a sequence of elemental images are not enough to remove the directional correlation between elemental images. The proposed method effectively sequences the elemental images from an integral image by the 2D referencing technique and compresses them using the multi-frame referencing of H.264/AVC. The proposed 2D referencing technique selects the optimal reference image according to vertical, horizontal, and diagonal correlation between elemental images. Experimental results show that compression with the sequence of elemental images presents better coding efficiency than that of still image compression. Moreover, the proposed 2D referencing technique is superior to the 1D scanning methods in terms of the objective performance and visual quality.

Comparison of Output and Radiation Quality of X-rays according to the Full-Wave Rectification Method and Dual-Voltage Rectification Method of an X-ray Generator (X선 고전압장치의 전파 및 배전압 정류방식에 따른 X선 출력 및 선질 비교)

  • Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.534-538
    • /
    • 2010
  • X-ray systems for medical treatment use noninvasive procedures. Being capable of locally inspecting the inside of the body, X-ray systems are routinely used for basic diagnosis. X-ray systems to be used for medical purposes were originally made with a gas filled tube inside an induction coil in the initial stages of development but with this approach it becomes difficult to take a satisfactory picture through thick body sections, non invasively. However continued development made it possible to take non-invasive pictures of breasts, blood vessels and other body parts through thick body sections. Recently, high-voltage X-ray generators of more compact size, increased generation efficiency, and sophisticated output control have become possible. All of these features are made possible by the use of a high-frequency output from an inverter and a fast switching semiconductor device. In this paper, we describe a new X-ray generator operating with a resonant inverter in order to reduce switching loss and high frequency noise. In addition, in order to identify the differences amongst types of rectification, we have compared output and the quality of X-ray pictures obtained with full-wave rectification and dual-voltage rectification methods.