Analysis on the Surface Luminance of Outdoor Lighting by Viewing Distance (경관조명의 시점거리별 표면휘도 특성분식)

  • Choi, Yoon-Seok;Jeong, In-Young;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.18-25
    • /
    • 2006
  • Existing outdoor lighting evaluation methods for the city beautification at night, the measurements are limited by one point to analyze the photometric data. However, this methods could not represent the diversity of photometric result from the distance. This study aims to propose the new outdoor lighting evaluation method of structure surface luminance in accordance with the measuring distance. For the purpose, the field measurement and simulation of an illuminated structure were conducted by CS-100, Digital Photometry Instrument ProMetric 1400, and the Lightscape v 3.2 from the distance of 100[m], 300[m], 500[m]. The result shows that evaluation of the surface luminance by the distance should be measured from about 100[m] of an illuminated object for getting the familiar result from computer simulation.

Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model (실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석)

  • Baik, Seung Heon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

Light Factor Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 주광조도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.23-31
    • /
    • 2007
  • This study aims to evaluate the illuminance performance of sloped light guide with automated venetian blind systems. For the purpose, a mock-up model was constructed as a prototype of Korean office building with $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and south facing side-window mounted between the clerestory window($2.0m^2$) and the view window($5.6m^2$). The light guide of 1.28m deepth and $29^{\circ}$ tilted angle, is covered with 0.6mm galvanized steel sheet and 97% reflective film. To protect the room from low solar angle, a blind systems, 0.15m deepth and $30^{\circ}$ automated slat angle was installed. To assess illuminance performance, the totally 37 measuring points for illuminance were monitored. For the detailed analysis, photometric sensors were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point) respectively. The performance was measured under clear sky and is monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons of light factor and uniformity are discussed.

An Analysis of the Somatotype of Elderly Women (노인여성의 측면체형 분석)

  • 최인순
    • Journal of the Korean Society of Costume
    • /
    • v.34
    • /
    • pp.19-36
    • /
    • 1997
  • through Sid View Silhouette The purpose of this study was to pro-vide basic information for elderly women's clothing construction and to develop dress forms that can reflect the charac-teristics of their bodies. The subjects were 251 elderly women aged from 60 to 81. Data were collected from 34 photographic measurements of each subject and analyzed by factor analysis cluster analysis analysis of variance. The results were as follows: 1. A decrease in height the bustline drops as age increase. From a lateral view point most of the subjects have straight posture with protruding ab-domens but the somatotype gradually bends bends forward with age. 2) Five factors were extracted from photometric measurement which explain 81.0% of variance. 3 Through cluster analysis using 5 fac-tor scores four types were categorized. Type I was turning over somatotype Type II was swayback somatotype Type III was straight somatotype Type IV was bending somatotype according to its po-sition to the relative plumb liner and their side view contour.

  • PDF

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

Interior Light Environment and Building Energy Performance Analysis of LED Lamp Installed in Office Building (LED램프를 적용한 사무소 건물의 실내조명환경 및 에너지 성능분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.77-85
    • /
    • 2010
  • In this paper, A new integrated energy simulation results of LED lamp are presented to use it effectively in the office buildings. Generally LED lamp has many advantages in comparison with a general lamp such as long life and no pollution problem like the mercury. It also is excellent in color rendering and small consumption electric power. However LED lamp has some disadvantages to compare to general fluorescent lamp. It is small light flux about 50[%] and narrow light distribution than fluorescent lamp. Therefore, to apply LED lamp in an office building, the illuminance distribution with an environment analysis and cooling, heating and light energy has to be analyzed. The purpose of this study is to analyze light environment, light, cooling and heating energy simulation in office building.

Luminance Assessment of Outdoor Lighting for Advertisements at Night (옥외광고용 발광조명의 야간휘도분포 분석)

  • Shin, Hwa Young;Lee, Jong Soo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.65-72
    • /
    • 2009
  • Lighting for outdoor advertising is very common feature of building facades as they provide the information and commercial identification. As the interest of improving street beautification more widely, application of various lighting technologies has been develop for advertisement such as electric sign board and signage. Furthermore, the installation of higher sign luminance than needed has many negative consequences, including higher energy consumption and light pollution. There are now no standard for outdoor advertisements in terms of luminance, and installation of indiscreet outdoor advertisement without luminance consideration is becoming more commonplace. This study was to evaluate the luminous characteristics of outdoor advertising as a function of sign and building facade luminance, luminance ratio. Data were collected on 8 electric sign boards, 20 internally illuminated, externally illuminated, neon, and channel letter signs and 4 commercial areas. Photometric measurements were taken by CS-100(Minolta) and ProMetric-1400(Radiant Imaging) for various sign modes and sign design. Also luminance of building facades were analyzed according with CIE standard of maximum obtrusive light permitted for exterior lighting installations. The findings are as follows; (1) There were excessive luminance of electric sign boards that could affect adjacent building facade and night sky luminance. (2) Sings that are externally illuminated providing an inappropriate amount of light on to the outer surface of the sign caused higher building facade luminance and potential of unnecessary glare.