• 제목/요약/키워드: Phase averaging

검색결과 124건 처리시간 0.03초

ANALYSIS OF TWOPHASE FLOW MODEL EQUATIONS

  • Jin, Hyeonseong
    • 호남수학학술지
    • /
    • 제36권1호
    • /
    • pp.11-27
    • /
    • 2014
  • In this paper, we propose closures for multi-phase flow models, which satisfy boundary conditions and conservation constraints. The models governing the evolution of the fluid mixing are derived by applying an ensemble averaging procedure to the microphysical equations characterized by distinct phases. We consider compressible multi species multi-phase flow with surface tension and transport.

위상 보상과 가중치 평균을 이용한 의료 초음파 신호의 주파수 특성 추출 방법 (Extraction Method of Ultrasound Spectral Information using Phase-Compensation and Weighted Averaging Techniques)

  • 김형석;이준환
    • 한국정보통신학회논문지
    • /
    • 제14권4호
    • /
    • pp.959-966
    • /
    • 2010
  • 정량적 초음파 분석(Quantitative Ultrasound Analysis)은 반향된 초음파 신호의 짧은 시간 간격의 주파수 성분을 추출하여 개별 초음파 지수의 값을 예측한다. 따라서 반향 신호의 정확한 주파수 특성 추출은 분석의 정확도와 정밀도 향상에 기본이 된다. 본 논문에서는 초음파 지수의 정량적인 예측 및 분석에 이용할 수 있는, 짧은 시간 간격의 반향 신호의 주파수 특성 추출 방법을 제안한다. 제안된 알고리듬은 인접한 반향 초음파 신호간의 위상 차이를 보상하고, 동일 반향 깊이를 가지는 작은 영역의 신호를 가중치 평균함으로써 보다 정확한 주파수 특성을 추출한다. 컴퓨터 모의 실험을 통한 수치 분석 결과, 제안된 알고리듬은 일반적인 주파수 추출 알고리듬보다 정확한 예측 결과를 보였으며, 예측 결과의 정밀도도 10% 이상 향상되었다.

A Novel Scheme for Sliding-Mode Control of DC-DC Converters with a Constant Frequency Based on the Averaging Model

  • He, Yiwen;Xu, Weisheng;Cheng, Yan
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2010
  • A new scheme for sliding-mode control (SMC) of DC-DC converters with a constant switching frequency is proposed. The scheme is based on the averaging model and the output signal of the controller is $d^+$ or $d^-$ instead of the on or off signal of a direct sliding-mode (SM) controller or the continuous signal d = $u_{eq}$ of an indirect SM controller. Two approaches using the new scheme are also proposed and the design procedures for a buck converter are given in detail. The first approach called constant $d^+$ and $d^-$ SMC is simple, cost effective and dynamically fast. In order to improve the dynamic characteristics of the reaching phase and to alleviate chattering, the second approach called reaching law SMC is also presented. Analyses and simulation results demonstrate the feasibility of the proposed scheme.

고속순차 최소자승법에 의한 선형위상 유한응답 여파기의 설계 (Fast Sequential Least Squares Design of FIR Filters with Linear Phase)

  • 선우종성
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1987년도 학술발표회 논문집
    • /
    • pp.79-81
    • /
    • 1987
  • In this paper we propose a fast adaptive least squares algorithm for linear phase FIR filters. The algorithm requires 10m multiplications per data point where m is the filter order. Both linear phase cases with constant phase delay and constant group delay are examined. Simulation results demonstrate that the proeposed algorithm is superior to the LMS gradient algorithm and the averaging scheme used for the modified fast Kalman algorithm.

  • PDF

주기적 선회실속이 발성하는 축류홴의 3차원 유동구조 (Three Dimensional Flow Structure under Rotating Stall in an Axial Flow Fan)

  • 강창식;신유환;김광호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.105-110
    • /
    • 2002
  • Experimental study was conducted to reveal the instability such as leakage flow and rotating stall in an axial flow fan. For this study, unsteady total pressure probe and multi-hole pressure probe were specially designed for measuring the flow field upstream and downstream of rotor. The measured pressure signal was analyzed by Single and Double Phase Locked Averaging Technique. From the result of total pressure fields at inlet and outlet of the rotor, the useful information on the structure of the stall cell in radial direction was provided. Also, detailed flow measurements were carried out with a specially designed high frequency multi-hole pressure probe, providing some insight to the leakage flow and their interation.

  • PDF

전력 손실 평균화 기법에 의한 3상 전압형 인버터의 소손 모드에 관한 연구 (A Study of Failure Mode for 3 Phase VSI by Power Loss Averaging Technique)

  • 조수억;박성준
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.575-580
    • /
    • 2010
  • This paper is to design an optimum power conversion device for the system required for development of a low cost 3-phase power inverter. For this purpose, in order to meet with endurance required by the industry, failure mode is standardized to guarantee lifetime of a power semiconductor by monitoring real time power loss and to facilitate failure mode analysis. As normality of heat loss of a power semiconductor is identified remaining in a certain range by comparing heat rise slope between that is calculated by using average current or average loss and that is measured at a heat sink, its feasibility is confirmed by experiment.

상태변수평균화법에 의한 삼상ICB회로 해석 (Analysis of the Three Phase Inductor-Converter Bridge Circuit by Means of State-Space Averaging Method)

  • 박민호;홍순찬;오수홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.394-398
    • /
    • 1988
  • In this paper, the time-averaged behavior of the three-phase Inductor-Converter Bridge (ICB) circuit has been analyzed by using the state-space averaging method. The results are in closed form far from the results obtained by using the Fourier series. Therefore, the computational difficulties of the infinite Fourier series can be avoided and the results derived in this paper are available especially in real time control. Unlike the SFC, $S^{4}LCL$, DFC and other circuits which have time varying switching intervals for a constant time-averaged value of coil voltage, the ICB circuits operate with a clock-driven sequence of gate pulses which have constant switching intervals.

  • PDF

축류송풍기의 실속셀 거동에 관한 실험적 연구 (Experimental Study on the Behavior of Stall Cell in an Axial Flow Fan)

  • 신유환;김광호;강창식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.643-646
    • /
    • 2002
  • Experimental study was conducted to reveal the flow mechanism under rotating stall in an axial flow fan. For this study unsteady pressure was measured using high frequency pressure transducers mounted on the casing wall of rotor passage and total pressure fields were measured at the rotor upstream and downstream. The measured pressure signal was analyzed by Wavelet Transform and Double Phase Locked Averaging Technique. From the result of unsteady pressure field of the casing wall, one period of rotating stall was divided into three zones and the flow characteristics on each zone were described in detail. The pressure field was also analyzed in terms of the pressure distribution along pressure side and suction side of blade tip. From the result of total pressure fields at inlet and outlet of the rotor, the useful information on the characteristics of the stall cell in radial direction was provided.

  • PDF

51-위상 출력 클록을 가지는 CMOS 위상 고정 루프 (A CMOS Phase-Locked Loop with 51-Phase Output Clock)

  • 이필호;장영찬
    • 한국정보통신학회논문지
    • /
    • 제18권2호
    • /
    • pp.408-414
    • /
    • 2014
  • 본 논문에서는 125 MHz 목표 주파수의 51-위상 출력 클록을 가지는 전하 펌프 위상 고정 루프(PLL)를 제안한다. 제안된 위상 고정 루프는 51-위상 클록을 출력하면서 최대 동작 주파수를 확보하기 위해 세 개의 전압 제어 발진기(VCO)를 사용한다. 17 단의 지연 소자는 각각의 전압 제어 발진기를 구성하며, 51-위상 클록 사이의 위상 오차를 줄이는 저항 평준화 구조는 세 개의 전압 제어 발진기를 결합시킨다. 제안된 위상 고정 루프는 공급전압 1.0 V의 65 nm 1-poly 9-metal CMOS 공정을 사용한다. 동작 주파수 125 MHz에서 시뮬레이션된 출력 클록의 peak-to-peak 지터는 0.82 ps이다. 51-위상 출력 클록의 차동 비선형성(DNL)과 적분 비선형성(INL)은 각각 -0.013/+0.012 LSB와 -0.033/+0.041 LSB이다. 동작 주파수 범위는 15 ~ 210 MHz이다. 구현된 위상 고정 루프의 면적과 전력 소모는 각각 $580{\times}160{\mu}m^2$과 3.48 mW이다.

다상화 dc/dc converter의 모델링 및 해석 (A Modeling and Analysis of Poly-phase dc/dc Converter)

  • 김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.512-515
    • /
    • 1991
  • The advantages of poly-phase converter are to be able to reduce the ripple current and to lessen the weight of power inductors. This paper is derived the equivalent circuit, dc of and ac modeling circuit of a 3-phase multiple buck converter by using state space representation and averaging techniche. Futhermore, it is represented the equivalent circuits according to the duty cycle.

  • PDF