• 제목/요약/키워드: Pet Hospital

검색결과 556건 처리시간 0.021초

Significantly Low Effective Dose from 18FDG PET/CT Scans Using Dose Reducing Strategies: "Lesser is Better"

  • uz Zaman, Maseeh;Fatima, Nosheen;Zaman, Areeba;Zaman, Unaiza;Tahseen, Rabia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권7호
    • /
    • pp.3465-3468
    • /
    • 2016
  • Background: Fluorodeoxyglucose ($^{18}FDG$) PET/CT imaging has become an important component of the management paradigm in oncology. However, the significant imparted radiation exposure is a matter of growing concern especially in younger populations who have better odds of survival. The aim of this study was to estimate the effective dose received by patients having whole body $^{18}F$-FDG PET/CT scanning as per recent dose reducing guidelines at a tertiary care hospital. Materials and Methods: This prospective study covered 63 patients with different cancers who were referred for PET/CT study for various indications. Patients were prepared as per departmental protocol and 18FDG was injected at 3 MBq/Kg and a low dose, non-enhanced CT protocol (LD-NECT) was used. Diagnostic CT studies of specific regions were subsequently performed if required. Effective dose imparted by 18FDG (internal exposure) was calculated by using multiplying injected dose in MBq with coefficient $1.9{\times}10^{-2}mSv/MBq$ according to ICRP publication 106. Effective dose imparted by CT was calculated by multiplying DLP (mGy.cm) with ICRP conversion coefficient "k" 0.015 [mSv / (mG. cm)]. Results: Mean age of patients was $49{\pm}18$ years with a male to female ratio of 35:28 (56%:44%). Median dose of 18FDG given was 194 MBq (range: 139-293). Median CTDIvol was 3.25 (2.4-6.2) and median DLP was 334.95 (246.70 - 576.70). Estimated median effective dose imparted by $^{18}FDG$ was 3.69 mSv (range: 2.85-5.57). Similarly the estimated median effective dose by low dose (non-diagnostic) CT examination was 4.93 mSv (range: 2.14 -10.49). Median total effective dose by whole body 18FDG PET plus low dose non-diagnostic CT study was 8.85 mSv (range: 5.56-13.00). Conclusions: We conclude that the median effective dose from a whole body 18FDG PET/CT in our patients was significantly low. We suggest adhering to recently published dose reducing strategies, use of ToF scanner with CT dose reducing option to achieve the lower if not the lowest effective dose. This would certainly reduce the risk of second primary malignancy in younger patients with higher odds of cure from first primary cancer.

FDG 사용 시 Dose Calibrator에 따른 SUV에 미치는 영향 (The Effect of Using Two Different Type of Dose Calibrators on In Vivo Standard Uptake Value of FDG PET)

  • 박영재;방성애;이승민;김상언;고길만;이경재;이인원
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.115-121
    • /
    • 2010
  • 방사성핵종과 방사능을 측정하는 dose calibrator의 서로 다른 두개의 기기에서 F-18 FDG을 각각 측정하고, 이 측정값에 의한 인체 내 SUV (Standard Uptake Value)에 미치는 영향은 없는지에 대하여 알아보고자 하였다. 이 연구에서 두개의 다른 dose calibrator는 CRC-15 Dual PET, CRC-15R을 사용하였다. 각 dose calibrator에서 F-18 FDG를 2 mL 주사기 3개에 볼륨 1 mL, 2 mL, 3 mL를 만들어 각각 초기 radio activity를 측정한 후 4시간 30분(270분)까지 30분 간격으로 radio activity를 각각 측정하고 기록한다. 초기 radio activity 값을 기준으로 방사선붕괴 공식으로 산출된 값(decay factor)과 dose calibrator로 측정된 값 간의 직선성을 단순선형을 통하여 분석하였다. CRC-15 Dual PET에서 가장 이상적인 값에 가까운 측정값을 볼륨을 기준으로 하여, CRC-15R에서 측정된 값을 최적화하기 위한 선형회귀식을 회귀분석을 통하여 구한다. 선형회귀식의 산출값을 적용하여 PET/CT 검사를 시행한 50명을 대상으로 lung, liver, region 부위에 ROI을 그려 SUV를 구한다. CRC-15 Dual PET, CRC-15R에서 측정한 radio activity와 그 값을 이용한 SUV를 paired t-test로 통계적으로 유의한 차이가 있는지 알아보았다. CRC-15 Dual PET과 CRC-15R에서 측정한 radio activity의 상관분석결과 1 mL의 경우 상관성을 보여주는 r값은 r=0.999이었으며, 회귀분석에 위한 선형식은 y=1.0345x+ 0.2601이었다. 2 mL의 경우 r=0.999이며, 선형회귀식은 y=1.0226x+0.1669이었다. 3 mL의 경우 r=0.999이며, 선형회귀식은 y=1.0094x+0.1577이었다. 각 세 가지 볼륨에서 얻어진 선형회귀식의 산출 값을 이용하여 구한 lung, liver, region 부위에 ROI의 SUV에서의 차이는 1 mL의 경우, lung, liver, region은 (p<0.0001)로 t-test 결과 모두 유의한 차이가 있었다. 2mL의 경우, lung (p<0.002), liver, region은 ROI의 SUV에서 유의한 차이(p<0.0001)를 보였다. 또한 3 mL의 경우, lung(p<0.044), liver, region의 유의한 차이(p<0.0001)가 있었다. F-18 FDG 검사에서 사용되는 두 개의 dose calibrator CRC-15 Dual PET, CRC-15R의 radioactivity에 대한 측정치에서는 상관관계의 차이가 없다는 것을 알 수 있었다. 그러나 이 두 값을 통해 SUV는 인체 내의 uptake 정도에 있어서는 유의한 차이를 보인다는 것을 알 수 있었다. 따라서 이 두개의 dose calibrator를 사용함에 있어서, 이 두 값이 인체 내 SUV의 차이를 고려하여 사용하여야 할 필요성이 요구된다.

  • PDF

전신 PET/CT 영상에서 조영제 영향의 보정 유.무에 따른 SUV 평가 (The Evaluation of SUV Using with and without Correction for Effect of Contrast Media in Whole Body PET/CT Imaging)

  • 남소라;손혜경;임한상;박훈희;조효민;이창래;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.246-251
    • /
    • 2006
  • 본 연구의 목적은 전신 PET/CT영상에서 조영제의 영향에 대한 보정 유 무가 SUV (standard uptake value)에 미치는 영향을 평가하는 것이었다. 영상획득은 GE DSTe PET/CT 시스템을 사용하였으며, 간질환(hepatocellular carcinoma, HCC)과 신장질환(renal cell carcinoma, RCC)이 있는 환자를 대상으로 하여 영상을 평가하였다. 영상 평가는 조영제에 의한 영향을 보정한 영상과 보정하지 않은 영상에서 각각 동일한 위치에 같은 크기의 관심영역을 설정한 후 각 관심영역으로부터 구한 SUV를 비교함으로써 수행하였다. HCC 환자의 경우 조영제에 의한 영향의 보정 유 무에 따른 평균 SUV의 차이는 $1.5{\pm}1.2%$이었고, 최대 4.3%의 SUV 차이를 나타내었다. RCC 환자의 경우 평균 SUV의 차이는 $1.0{\pm}0.9%$이었고, 최대 1.9%의 SUV 차이를 나타내었다. 조영제를 사용한 PET/CT 영상에서 조영제에 의한 영향을 보정하지 않았을 경우는 조영제에 의한 영향을 보정해준 경우에 비해 상대적으로 높은 SUV를 나타내었다. 본 연구의 결과는 HCC 환자와 RCC 환자의 경우 조영제에 의한 영향을 보정한 경우와 보정하지 않은 경우 SUV에 큰 차이를 보이지는 않았으나, 향후 보다 많은 수의 HCC 환자와 RCC 환자를 대상으로 한 추가적인 연구가 필요할 것이라고 생각한다. 또한 다른 질환을 가진 환자의 경우에 대해서도 조영제가 SUV에 미치는 영향을 평가하는 것은 매우 유용하리라 생각한다.

  • PDF

폐소공포증 환자의 핵의학 영상검사에 관한 연구 (Study of Nuclear medical imaging tests patient of Claustrophobia)

  • 강용길;홍진웅;양한준;박성수;이귀원;김긍식
    • 대한디지털의료영상학회논문지
    • /
    • 제15권1호
    • /
    • pp.55-59
    • /
    • 2013
  • Patients who had claustrophobia tend to feel fear when they were scanned by an MRI, CT, PET-CT, or using a gamma camera scan. In this paper, claustrophobic patients were tested to find effective ways by changing patient's positions. For this paper, PET-CT scan in patients who had claustrophobia were used in the prone position. Prone position helped to maintain stable position and to get a h0igh quality of inspection without failure. Thus, as claustrophobic patients were requested taking prone position, they could feel comfortable. In a confined space, prone position for the claustrophobic patients who had a fear of the PET-CT examination would be expected to reduce the failure rate of inspection.

  • PDF

반려동물 질병예측서비스 및 통합관리 어플리케이션 (Pet Disease Prediction Service and Integrated Management Application)

  • 표기두;이동영;정원세;권오준;한경숙
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.133-137
    • /
    • 2023
  • 본 논문에서는 반려동물 AI 진단, 동물병원 찾기, 스마트 가계부, 커뮤니티 기능을 하나로 모은 '반려동물 종합관리 어플리케이션'을 개발하였다. 해당 어플리케이션은 여러 기능을 각각의 다른 어플리케이션으로 사용해야 하는 사용자의 불편함을 해소할 수 있으며, 사진을 통해 쉽게 반려동물 AI 진단 서비스를 이용할 수 있고, 크롤링을 이용한 동물병원 정보 제공과 주변의 동물병원 찾기, OCR 텍스트 추출 기법으로 영수증을 스캔할 수 있는 스마트 가계부, 어플리케이션 사용자 간의 커뮤니티 기능을 지원한다. 본 어플리케이션을 사용함으로써 반려동물의 건강, 소비내역 등 양육에 필요한 정보를 하나의 시스템으로 관리할 수 있게 된다.

핵의학 융합영상의 표준섭취계수 차이에 관한 연구 (Study on the Difference of Standardized Uptake Value in Fusion Image of Nuclear Medicine)

  • 김정수;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.553-560
    • /
    • 2018
  • PET-CT and PET-MRI which integrates CT using ionized radiation and MRI using phenomena of magnetic resonance are determined to have the limitation to apply the semi-quantitative index, standardized uptake value (SUV), with the same level due to the fundamental differences of image capturing principle and reorganization, hence, their correlations were analyzed to provide their clinical information. To 30 study subjects maintaining pre-treatment, $^{18}F-FDG$ (5.18 MBq/㎏) was injected and they were scanned continuously without delaying time using $Biograph^{TM}$ mMR 3T (Siemens, Munich) and Biograph mCT 64 (Siemens, Germany), which is an integral type, under the optimized condition except the structural differences of both scanners. Upon the measurement results of $SUV_{max}$ setting volume region of interest with evenly distributed radioactive pharmaceuticals by captured images, $SUV_{max}$ mean values of PET-CT and PET-MRI were $2.94{\pm}0.55$ and $2.45{\pm}0.52$, respectively, and the value of PET-MRI was measured lower by $-20.85{\pm}7.26%$ than that of PET-CT. Also, there was a statistically significant difference in SUVs between two scanners (P<0.001), hence, SUV of PET-CT and PET-MRI cannot express the clinical meanings in the same level. Therefore, in case of the patients who undergo cross follow-up tests with PET-CT and PET-MRI, diagnostic information should be analyzed considering the conditions of SUV differences in both scanners.

신경 베체트병 1례: 신경학적 증상과 뇌 PET, SPECT, MRI 소견의 비교 (A Case of Neuro-Behest's Disease: Comparison of Neurological Symptoms with PET, SPECT, and MRI Findings)

  • 김진욱;안민;김소연;김영중;조민구;이권전;임상무;홍성운;최창운
    • 대한핵의학회지
    • /
    • 제32권6호
    • /
    • pp.534-541
    • /
    • 1998
  • We describe a 27-year-old man who developed gait disturbance and dysarthria 2 years after the onset of cardinal symptoms of Behcet's disease. Positron emission tomography with $^{18}F$-fluorodeoxyglucose revealed severe hypometabolisrn in the cerebellum, in accordance with cerebellar symptoms and signs of the patient. However, single-photon emission tomography with $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD did not disclose significant perfusion abnormalities in the brain. Routine brain magnetic resonance imaging did not show signal abnormalities. The findings of imaging studies compared with neurological manifestations of the patient are discussed.

  • PDF

Primary Pelvic Peritoneal Yolk Sac Tumor in the Post-Pubertal Female: a Case Report with Literature Review

  • Kim, Myojeong;Lee, Eun Ji;Hwang, Jiyoung;Hong, Seong Sook;Chang, Yun-Woo;Oh, Eunsun;Nam, Bo Da;Choi, Inho;Kim, Jeong Sig
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권4호
    • /
    • pp.367-373
    • /
    • 2019
  • Yolk sac tumors are rare malignant germ cell neoplasms that usually arise from the gonads. Extragonadal yolk sac tumors (EGYSTs) frequently occur in the mediastinum in post-pubertal females. EGYSTs in the pelvis are extremely rare, and to date, only thirteen cases have been reported in the English literature. Among them, the primary EGYST of the pelvic peritoneum in post-pubertal females has only been reported in ten cases. The present case describes a 26-year-old female diagnosed with primary peritoneal yolk sac tumor located in the rectouterine pouch. We report clinical and tumor imaging features, including ultrasound, computed tomography (CT), magnetic resonance images (MRI), positron emission tomography-computed tomography (PET-CT), and present a review of the literature.

Current Radiopharmaceuticals for Positron Emission Tomography of Brain Tumors

  • Jung, Ji-hoon;Ahn, Byeong-Cheol
    • Brain Tumor Research and Treatment
    • /
    • 제6권2호
    • /
    • pp.47-53
    • /
    • 2018
  • Brain tumors represent a diverse spectrum of histology, biology, prognosis, and treatment options. Although MRI remains the gold standard for morphological tumor characterization, positron emission tomography (PET) can play a critical role in evaluating disease status. This article focuses on the use of PET with radiolabeled glucose and amino acid analogs to aid in the diagnosis of tumors and differentiate between recurrent tumors and radiation necrosis. The most widely used tracer is $^{18}F$-fluorodeoxyglucose (FDG). Although the intensity of FDG uptake is clearly associated with tumor grade, the exact role of FDG PET imaging remains debatable. Additionally, high uptake of FDG in normal grey matter limits its use in some low-grade tumors that may not be visualized. Because of their potential to overcome the limitation of FDG PET of brain tumors, $^{11}C$-methionine and $^{18}F$-3,4-dihydroxyphenylalanine (FDOPA) have been proposed. Low accumulation of amino acid tracers in normal brains allows the detection of low-grade gliomas and facilitates more precise tumor delineation. These amino acid tracers have higher sensitivity and specificity for detecting brain tumors and differentiating recurrent tumors from post-therapeutic changes. FDG and amino acid tracers may be complementary, and both may be required for assessment of an individual patient. Additional tracers for brain tumor imaging are currently under development. Combinations of different tracers might provide more in-depth information about tumor characteristics, and current limitations may thus be overcome in the near future. PET with various tracers including FDG, $^{11}C$-methionine, and FDOPA has improved the management of patients with brain tumors. To evaluate the exact value of PET, however, additional prospective large sample studies are needed.

18F-FDG PET를 이용한 미세먼지 노출에 따른 쥐(rat)의 뇌 활성도 변화 (Changes in Brain Activity of Rats due to Exposure to Fine Dust Using 18F-FDG PET)

  • 조윤호;조규상;이왕희;최재호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.225-232
    • /
    • 2022
  • Fine dust threatens human health in various forms, depending on the particle size, such as by causing respiratory, cardiovascular, and brain diseases, after entering the body via the lungs. The aim of this study was to correlate fine dust exposure with changes in brain blood flow in Sprague Dawley rats by using micro-positron emission tomography and elucidate the possibility of developing cerebrovascular diseases caused by fine dust. The subjects were exposured to an average fine dust (particulate matter 2.5) of 206.2 ± 7.74 to ten rats four times a day, twice a day for 90 min. Before the experiment, they were maintained at NPO to the maximize the intake of 18F-fluorodeoxy glucose(18F-FDG) and minimize changes in the 18F-FDG biomass depending on the ambient environment and body temperature of the rats. PET images were acquired in the list mode 40 min after injecting 18F-FDG 44.4 MBq into the rats tail vein using a micro-PET scanner pre and post exposure to fine dust. We found that the whole brain level of 18F-FDG standardized uptake value in rats averaged 5.21 ± 0.52 g/mL pre and 4.22 ± 0.48 g/mL post exposure to fine dust, resulting in a statistically significant difference. Fine dust was able to alter brain activity after entering the body via the lungs in various forms depending on the particle size.