• Title/Summary/Keyword: Performance standards

Search Result 2,375, Processing Time 0.026 seconds

Analysis of Clinical Nursing Activities Using Home Hospice Nursing Intervention Standards (가정호스피스 간호중재 표준서에 의한 임상간호활동 분석)

  • Yong, Jin-Sun
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.6
    • /
    • pp.960-972
    • /
    • 2008
  • Purpose: The purpose of this study was to validate the nursing intervention standards of home care to home care setting for a guide in giving quality care to home hospice patients. Methods: The developed nursing standards were applied to 79 home hospice patients at K hospital, C university. Data were collected through the developed nursing intervention standards of home care with 19 selected nursing interventions and 418 associated nursing activities from January to June in 2006. Results: The performance frequency was 509 times for total nursing interventions and 7,815 times for total associated nursing activities. The most frequently used nursing activity was 722 times(9.24%) on teaching prescribed medication, followed by surveillance(718 times, 9.18%), and vital signs & neurologic monitoring nursing intervention(701 times, 8.97%). The highest mean nursing activity performance rate showed on Intravenous therapy(82%), followed by dying care(81%), and vital signs & neurologic monitoring (80%). Among 418 nursing activities, there were three classifications: 168 as core activities, 165 as major, and 85 as accessory activities. Conclusion: The final validated nursing intervention standards can guide home care nurses to perform quality care and contribute to computerized nursing services and request of nursing fees.

  • PDF

Design of performance testing device for heat exhaust ventilation fan (제연용 송풍기의 방염성능 시험장치 설계)

  • Lee, Young-Mo;Kim, Kwang-Yong;Lee, Jae-Yup;Jung, Hyun-Jong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.367-372
    • /
    • 2005
  • This study primarily is concerned with a new device which has been developed following the international standards to measure the ventilation performance at elevated temperature. This device can measure duration of ventilation, performance of electricity, static pressure at elevated temperature and also it is having provision to measure reversible performances during fire hazards. Invented device is closed circuit type system which is best suited for korean industrial environment with low cost and high efficiency. International standards has been compared and performance testing has been major using BS 7346 which is tested by Warrington Fire Research Centre.

  • PDF

Research Trends for Performance, Safety, and Comfort Evaluation of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Ryu, Myong-Jin;Chung, Sun-Ok;Kim, Yong-Joo;Choi, Chang-Hyun;Hong, Soon-Jung;Sung, Je-Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.1
    • /
    • pp.21-33
    • /
    • 2014
  • Background: Significant technological development and changes happened in the tractor industries. Contrariwise, the test procedures of the major standard development organizations (SDO's) remained unchanged or with a little modification over the years, demanding new tractor test standards or improvement of existing ones for tractor performance, safety, and comfort. Purpose: This study focuses on reviewing the research trends regarding performance, safety and comfort evaluation of agricultural tractors. Based on this review, few recommendations were proposed to revise or improve the current test standards. Review: Tractor power take-off power test using the DC electric dynamometer reduced human error in the testing process and increased the accuracy of the test results. GPS signals were used to determine acceleration and converted into torque. High capacity double extended octagonal ring dynamometer has been designed to measure drawbar forces. Numerical optimization methodology has been used to design three-point hitch. Numerous technologies, driving strategies, and transmission characteristics are being considered for reducing emissions of gaseous and particulate pollutants. Engine emission control technology standards need to be revised to meet the exhaust regulations for agricultural tractors. Finite Element Analysis (FEA) program has been used to design Roll-Over Protective Structures (ROPS). Program and methodology has been presented for testing tractor brake systems. Whole-body vibration emission levels have been found to be very dependent upon the nature of field operation performed, and the test track techniques required development/adaptation to improve their suitability during standardized assessment. Emphasizes should be given to improve visibility and thermal environment inside the cab for tractor operator. Tractors need to be evaluated under electromagnetic compatibility test conditions due to large growing of electronic devices. Research trends reviewed in this paper can be considered for possible revision or improvement of tractor performance, safety, and comfort test standards.

A Study on Floor Slip Resistance Standard and Test Method for BF Certification (BF인증을 위한 바닥 마감재 미끄럼 성능기준 및 측정방법에 대한 연구)

  • Shin, Dong-Hong;Seong, Ki-Chang;Park, Kwang-Jae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.75-83
    • /
    • 2019
  • Purpose: There are no clear criteria for slip performance in the BF certification process, so the evaluator relies on subjective judgments depending on the field situation. Physical criteria for determining the slip performance of various floor finishes are not clear. C.S.R., the only criterion currently being used to check slip performance, may raise questions about its coverage, feasibility and reliability. Method: For an analysis of domestic standards and status, KS L 1001, KS M 3510, and KS F 2375. External standards are analyzed for ADA Standard, ANSI Standard, and BS EN Standard. Analyze the test methods and evaluation criteria of O-Y-PSM, BPT, and the dynamic slip resistance test used in these criteria. It also presents an improvement plan for the rational presentation of standards. Results: To date, various kinds of test methods and measuring devices of the slip resistance coefficient have been developed, but there are not many ways to trust useful results related to user safety. Reliability and thoroughly verified test methods and criteria should be used to assess the slip performance of the floor. In order to improve the standard for the evaluation of slip performance in Korea, the existing standard should first be raised to the same level as the overseas standard, and the application of the discriminatory standard should be applied considering the characteristics and usage patterns of each space. Implication: Currently, Korean standards propose various test methods, but the proper use of test methods, scope and assessment criteria are not established, so improvement of the comprehensive standard is necessary.

Verification and Improvement of Structural Behavior Response Performance Evaluation Method for the Standard Establishment of Adhesive Composite Waterproofing Sheets (점착형 복합 방수시트의 표준(안)제정을 위한 구조물 거동대응성능 시험방법 개선 및 검증 평가 연구)

  • Kim, Soo-Yeon;Park, Jong-Sun;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.4
    • /
    • pp.377-386
    • /
    • 2021
  • In April 2019, this study was enacted as a test method for the performance of waterproof layers in an environment where complex deterioration and structural behavior are simultaneously applied, but some existing standards were implemented to point out the errors of the method that should be supplemented. Thus, in establishing standards for (tentative) adhesive waterproofing sheets, field workability and quantification of test results were studied on the structural behavior response performance test methods included as test items. In addition, the performance evaluation of adhesive-type composite waterproof sheets was conducted based on the considered contents to review improvements such as applicability as an item of standard standards and field workability related problems.

Formulation of a New En Score in the Proficiency Test

  • Chul-Young Yi;In Jung Kim;Jong In Park;Yun Ho Kim;Young Min Seong
    • Progress in Medical Physics
    • /
    • v.35 no.1
    • /
    • pp.16-19
    • /
    • 2024
  • A new En score of the proficiency test (PT) is formulated; it is applicable when a correlation exists between the reference and participant's values. Based on the uncertainty propagation rule given in ISO/IEC Guide 98-3 (GUM:1995), the En score covering the correlation case is newly developed for the PT. The new En score will be applied in a future PT organized by the Korea Research Institute of Standards and Science (KRISS) dosimetry team. The new En score will enhance measurement traceability and contribute to improving the quality management system of participants in the KRISS PT by avoiding performance underestimation.

International Standards of Electrical Equipments for Medical Practice (의료용 전기기기에 대한 국제표준 현황)

  • Lee, Tae-Bum
    • The Korean Journal of Health Service Management
    • /
    • v.7 no.3
    • /
    • pp.203-212
    • /
    • 2013
  • Medical devices separated by a committee of the International Electrotechnical Commission IEC TC (Technical Committee) 62 medical electrical equipment being promoted by the International standards. Actually, a lot of standards were existed, but many national and international standards for medical devices were lacking in practical standards that can be applied to their development. Most international standards were focused in electrical and mechanical safety of medical devices. Therefore, there were few practical standards which contain essential performance evaluation. Although medical device regulations do not enforce a fixed lifecycle model, activities are presented in a sequential manner, thus hinting at a waterfall process. Meanwhile, for a decade or more, software teams have benefitted from agile development methods. Several medical device manufacturers have adopted agile practices while keeping development in compliance with regulations, but conflicts arise and decisions have to be taken in favor of agility or formality. However, if there are new practical standards of medical devices, it must be possible to promote the medical devices industry in their nation. To do this, there is a need to develop a new standard could apply to the international market through the analysis of the medical device related technology. Consequently, new standards such as NP (New proposal) or NWIP (New Work Item Proposal) should be developed through international standardization of medical device technology.

A Review on ISO Standards Applicable for a Human Error Tolerant Control Center Design (제어실의 인적오류 예방에 적용 가능한 ISO 표준 검토)

  • Lee, Dhong-Ha
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.161-168
    • /
    • 2011
  • Objective: The aim of this study is to review the ISO(the International Organization for Standardization) standards recommendations on a human error tolerant control room design. Background: ISO TC(Technical Committee) 159 published a variety of international standards on design of mental and physical work, design of displays and controls, and workstation layout design. A proper edition of these standards can be a good resource for a human error tolerant control center design guidelines. Method: Recommendations of ISO TC 159 standards were grouped into arrangement of control suite, layout of control room, layout and dimensions of workstations, design of displays and controls, environmental design, alarm, automation, management system design, procedure and training. Results: It was found that some standards on the design of supervisory control and data acquisition(SCADA), alarm, automation, layout, workload management, and environment can be used for human error prevention guidelines in the control center design. Conclusion: ISO TC 159 standards were not sufficient to cover all the ergonomics area of control center design. Application: Designers can have technical aids from these ISO standards to improve ergonomic performance of their control center.

Assessing Participation in the ISO/IEC Standards Development by Country (ISO/IEC에서의 국가별 무역기술표준 개발 참여 평가)

  • Kim, Na-Young
    • Korea Trade Review
    • /
    • v.44 no.4
    • /
    • pp.87-100
    • /
    • 2019
  • A country's participation in international technical standards development directly relates to its trade competitiveness. Many countries adopt international standards or influence their development process through the ISO/IEC. This study applies the ABCD Model to assess such activities through a constructed ITS index, not only in terms of 'level' of contribution but also in terms of 'process' participation that can give important implications related to the future potential influence of countries in standards development. Having examined seven countries, Korea showed the lowest score implying the need to enhance its performance in both 'international standards adoption' and 'internationalization of domestic standards'. Korea needs to more actively participate in currently on-going standards development processes, establish more offices that improve accuracy in the development, and consider participating in additional committees where domestic interests may potentially be at stake. Although KATS has improved greatly in regards to its relevant activities and database construction, a more active and specific plan must be made to allow its efforts to successfully influence Korea in international standards development. Confronted with strong challenges from directly competing countries in trade like China and Japan that showed better ITS scores, there is a need for Korea to step up its research and participation in this field.

A Study on the Development and Application of Performance Evaluation Model for Defense Standard Improvement Projects (국방규격 개선사업의 성과평가모형 개발 및 적용방안 연구)

  • Lee, Min Cheol;Kim, Young Hyun;Ahn, Young Jun;Kim, Jun Su
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.2
    • /
    • pp.185-202
    • /
    • 2023
  • Purpose: The purpose of this study is to identify key performance evaluation items and factors that are effective and practical for project management of defense standard standard improvement projects, and to develop a quantitative performance evaluation model. Methods: For the development of a performance evaluation model for defense standard improvement projects, we analyzed past major project performance and derived evaluation items and factors. To increase the objectivity and efficiency of project evaluation, we developed an evaluation index that enables relative evaluation of evaluation targets, and calculated the main importance of evaluation items using the Analytic Hierarchy Process (AHP) method based on the main opinions of expert groups. Results: The study resulted in the identification of main performance items for defense standard improvement projects, which were classified into defense standard conformity review performance and defense standard improvement performance items. We also simplified the evaluation model by integrating various evaluation items into similar evaluation factors. Additionally, we developed a quantitative evaluation index that enables relative evaluation of the targets and verified the objectivity and validity of the suggested performance evaluation model by reevaluating it using performance data from past commissioned professional institutions Conclusion: Developing a quantitative evaluation model for defense standard improvement projects is expected to provide a means of measuring the effectiveness of the project, and to be used as a tool to determine the appropriateness and effectiveness of medium and long-term project plans.