Automatic Diameter Control System with Long Time-Delay for Crystal Grower (FF - CZ150) (긴 시간지연을 갖는 단결정 실리콘 성장기(Crystal Grower - FF CZ150)의 자동 직경 제어 시스템)

  • Park, Jong-Sik;Kim, Jong-Hun;Yang, Seung-Hyun;Lee, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2089-2092
    • /
    • 2002
  • The PID controller have the simple structure and show the comparatively good control performance. Crystal Grower(FF-CZ150) melt polycrystalline silicon at the temperature of about 1450$^{\circ}C$, then grow it into a single crystalline ingot. The automatic diameter control system of the Crystal Grower has a good performance with only PD control. But it contain the integrator in the plant which has a long time delay. In this paper, we show the secondary approximate model and applies time delay controller which has good performance for the plant with long time delay. It will be able to improve the response characteristic against a standard input and a load disturbance.

  • PDF

Development of Width Control System at Top of Strip for Hot Finishing Mill (열간 사상압연 선단부 폭 제어 시스템 개발)

  • Park, Cheol-Jae;Lee, Duk-Man
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.152-157
    • /
    • 2001
  • This paper presents the design method of the new controller for looper system in hot strip finishing mill. Looper response time is related to the performance of the tension control to reduce the delivery width error. The quality of the hot strip product, especially width deviation at the top of the strip, is influenced greatly by the precision of tension control. In this paper, a new fuzzy PID control system is designed to obtain the fast looper angle response and the high control precision. The computer simulation to verify the performance of the new controller is executed. From the results of the simulation, the tension control can obtain better performance than that of the conventional PID case.

  • PDF

An Effective Control Chart for Monitoring Mean Shift in AR(1) Processes (AR(1) 공정에서의 효과적인 공정평균 관리도)

  • 원경수;강창욱;이배진
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.24 no.67
    • /
    • pp.27-36
    • /
    • 2001
  • A standard assumption when using a control chart to monitor a process is that the observations from the process output are statistically independent. However, for many processes the observations are autocorrelated and this autocorrelation can have a significant effect on the performance of the control chart. In this paper, we consider combined control chart of monitoring the mean of a process in which the observations can be modeled as a first-order autoregressive process. The Shewhart control chart of residuals-EWMA control chart of the observations is considered and the method of combination is recommended. The performance of the proposed control chart is compared with the performance of other control charts using a simulation.

  • PDF

Minimization of Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Condition

  • Park, Yonggyun;Suh, Yongsug;Go, Yuran
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.273-274
    • /
    • 2012
  • This paper investigates control algorithms for a doubly fed induction generator(DFIG) with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Two different control algorithms to compensate for unbalanced conditions are proposed. Evaluation factors of control algorithm are fault ride-through(FRT) capability, efficiency, harmonic distortions and torque pulsation. Zero regulated negative sequence stator current control algorithm has the most effective performance concerning FRT capability and efficiency. Ripple-free control algorithm nullifies oscillation component of active power and reactive power. Ripple-free control algorithm shows the least harmonic distortions and torque pulsation. Combination of zero regulated negative sequence stator current and ripple-free control algorithm control algorithm depending on the operating requirements and depth of grid unbalance presents the most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system.

  • PDF

A minimum energy control of a load-sensing hydraulic servo system

  • Kim, S.D.;Cho, H.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.747-752
    • /
    • 1987
  • The dynamic characteristics of a load-sensing hydraulic servo system are complex and highly unstable. Another property of the system is that the setting value of pump compensator is closely related to energy efficiency as well as control performance of the system. This necessitates the development of an effective control algorithm which guarantees good control performance, stability and energy efficiency. This paper considers a suboptimal PID control for the velocity control problem of the load-sensing hydraulic servo system. The results of simulations studies and experiments show that the proposed suboptimal controller can produce much better control performance than nonoptimal controllers and give effective energy efficiency.

  • PDF

Influence of Memory Intensive Training Program on Cognitive Function, Memory Performance, and Self-Esteem in Elderly People (기억강화프로그램이 노인의 인지기능, 자아존중감과 기억수행에 미치는 영향)

  • Jung, Myung-Sook;Kim, Jeong-Hwa
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.13 no.2
    • /
    • pp.161-170
    • /
    • 2010
  • Purpose: This study was to confirm the influence of memory intensive training program on the elderly people's cognitive function, memory performance, and self-esteem. Method: Using a quasi-experimental or experimental design, 60 elderly aged over 60 years randomly assigned the experimental and control groups completed pretest-post evaluation. The experimental group participated in the memory intensive training program was offered to the participants in the experimental group for three weeks (2times/week). The t-test and $X^2$-test using SAS program. Results: 1) The cognitive function was significantly higher in the experimental group compared to that in the control group (t=3.26, p=.002). 2) The memory performance that included immediate word recall tasks, word recognition tasks and delayed word recall tasks was significantly higher in the experimental group than in the control group (t=5.30, p<.001). The experimental group showed significantly higher scores for memory performance than the control group (t=5.30, p<.001). 3) The self-esteem was higher in the experimental group than in the control group, but there was no significant difference between the two groups (t=1.94, p=.058). Conclusion: The Memory Intensive Training Program could be an effective intervention for improving cognitive function, and memory performance of the elderly people.

Performance Improvement of Air Conditioner Network System using Wireless Sensors Through System Performance Index and Dynamic Power Distribution Control (시스템 성능 지수 및 동적 전력분산 제어를 통한 무선센서를 이용한 에어컨 네트워크 시스템의 성능 개선)

  • Choi, Ho-seek;Kwon, Woo-hyen;Yoon, Byung-keun
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.64-70
    • /
    • 2019
  • Wireless sensors have been developed in numerous ways for enhancing the convenience of installation, management and maintenance of sensors. Energy harvesting wireless sensors, which can collect energy from the external environment for permanent usage without the need of recharging and exchanging batteries, have been developed and employed used in Internet of Things and at various industrial sites. Energy harvesting wireless sensors are significantly affected by the sensor lifespan to sudden variation in the external environment. Furthermore, reduction in the sensor operating timespan can greatly affect the characteristics of the devices connected through a network. In this paper, a system performance index is proposed that can comprehensively evaluate the lifespan of a solar cell wireless sensor, determine the characteristics of devices connected to the associated network, and recommend dynamic power distribution control for improving the system performance index. Improvement in the system performance index was verified by applying the proposed dynamic power distribution control to an air conditioner network system using a solar cell wireless sensor. Obtained results corroborate that the dynamic power distribution control can extend the lifespan of the incorporated wireless sensor and reduce the air conditioner's power consumption.

Development of Multiple RLS and Actuator Performance Index-based Adaptive Actuator Fault-Tolerant Control and Detection Algorithms for Longitudinal Autonomous Driving (다중 순환 최소 자승 및 성능 지수 기반 종방향 자율주행을 위한 적응형 구동기 고장 허용 제어 및 탐지 알고리즘 개발)

  • Oh, Sechan;Lee, Jongmin;Oh, Kwangseok;Yi, Kyongsu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.2
    • /
    • pp.26-38
    • /
    • 2022
  • This paper proposes multiple RLS and actuator performance index-based adaptive actuator fault-tolerant control and detection algorithms for longitudinal autonomous driving. The proposed algorithm computes the desired acceleration using feedback law for longitudinal autonomous driving. When actuator fault or performance degradation exists, it is designed that the desired acceleration is adjusted with the calculated feedback gains based on multiple RLS and gradient descent method for fault-tolerant control. In order to define the performance index, the error between the desired and actual accelerations is used. The window-based weighted error standard deviation is computed with the design parameters. Fault level decision algorithm that can represent three fault levels such as normal, warning, emergency levels is proposed in this study. Performance evaluation under various driving scenarios with actuator fault was conducted based on co-simulation of Matlab/Simulink and commercial software (CarMaker).

Study on Influence of Rotor Temperature Variation on the Performance of Maximum Torque Per Amp Control Strategy (단위 전류당 최대 토크 제어기 성능에 미치는 로터 온도 변화의 영향에 대한 연구)

  • Kwon, Chun-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3110-3114
    • /
    • 2009
  • Rotor temperature variation is a significant issue in the design of induction motor controls. In the literature, numerous studies have mentioned significant performance degradation due to rotor temperature variation unless it is taken into account. However, those studies have mainly focused on field-oriented control in terms of tracking performance. There was little research about the influence of rotor temperature variation on performance particularly in the case of optimal controls such as maximum torque per amp (MTPA) control strategy. This work investigates how to affect the performance of maximum torque per amp (MTPA) control strategy as rotor temperature varies in time. To this end, investigation was carried out in two ways to see whether the objective of MTPA control strategy is achieved regardless of rotor temperature variation. It is to produce a desired torque with the minimum possible stator current at the same time. Laboratory experiment shows that tracking performance and maximum torque per amp condition is significantly affected by rotor temperature variation as rotor temperature varies, thus ending up with performance degradation of MTPA control.

Tracking control for multi-axis system using two-degrees-of-freedom controller

  • Park, Ho-Joon;Lee, Je-Hee;Huh, Uk-Youl
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.380-384
    • /
    • 1996
  • This paper represents an adaptive position controller with the disturbance observer for multi-axis servo system. The overall control system consists of three parts : the position controller, the disturbance observer with free parameters and cross-coupled controller which enhances contouring performance by reducing errors. Using two-degrees-of freedom conception, we design the command input response and the closed loop characteristics independently. The servo system can improve the closed loop characteristics without affecting the command input response. The characteristics of the closed loop system is improved by suppressing disturbance torque effectively with the disturbance observer. Moreover, the cross-coupled controller enhances tracking performance. Thus total position control performance is improved. Finally, the performance of the proposed controller shows that it improves the contouring performance along with the reference trajectory in the XY-table.

  • PDF