• Title/Summary/Keyword: Peak Temperature

Search Result 3,069, Processing Time 0.027 seconds

The Dielectric Properties due to the Temperature and Applied Voltage of Oriented Polypropylene Film Irradiated by $^{60}/Co-${\gamma}$$ ($^{60}/Co-${\gamma}$$선으로 조사된 이축연신 폴리프로필렌 필림의 온도 및 전압에 따른 유전특성)

  • 홍진웅;이수원;김왕곤
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.48-55
    • /
    • 1994
  • In this paper, It is studied that the variation of the dielectric absorption of the specimen according to the change with $^{60}$ Co-${\gamma}$ ray irradiation dose of the influence of temperature and applied voltage. In order to investigate the effect of irradiated oriented polypropylene film, we have observed dielectric properties within the temporature range of 30~130 ($^{\circ}C$) and voltage range of 100~250 (V). As for the dependency of temperature by tan $\delta$, the $\alpha$ peak which appears at high temperature increases accordingly to the increment of irradiation dose which is contributed by the crystal region and moves towards the high temperature. The $\beta$ peak which appears the orientation by dipoles and molecular motions in the amorphous region at low temperature. For the dependency of voltage by tan $\delta$ at low temperature, the peak of the tan $\delta$ shifts accordingly to the increment of irradiation dose towards the high temperature region.

  • PDF

PL Study on the Oxygen-Plasma-Treated ZnO Thin Film (산소 플라즈마 처리 후 ZnO 박막에 대한 PL 연구)

  • Cho, Jae-Won;Rhee, Seuk-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.12
    • /
    • pp.992-995
    • /
    • 2011
  • The optical properties of ZnO thin film, being treated by O-plasma, have been studied using Photoluminescence(PL) spectroscopy with the change of temperature from 10 K to 290 K. Two characteristic peaks were identified at 10 K : 3.357 eV($D^{\circ}X$) and 3.324 eV(TES). The peak of $D^{\circ}X$ is believed to be due to neutral donor bound excitons where the donor is in the ground state. However, the TES(Two Electron Satellite) peak indicates the excited state of the donor(excitation energy was ~30 meV). The donor binding energy was estimated to be 44 meV, which indicates the possible presence of the neutral donor bound excitons at RT. The thermal effect including thermal broadening was identified from temperature evolution of the spectrum. Both the peak intensity and the peak energy have decreased as the temperature increases. As the temperature approaches to RT, the two peak merges into one broad peak, which is considered a combination of multiple peaks having different physical origins.

Thermal Analysis of Mg Hydride by Sievert's Type Automatic Apparatus (Sievert's type 자동장치에 의한 마그네슘 수소화합물의 열분석)

  • Han, Jeong Seb;Park, Kyung Duck
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.12
    • /
    • pp.1123-1129
    • /
    • 2010
  • In order to apply the Sievert's type automatic apparatus to thermal analysis of hydrogen absorbing materials, the dehydrogenation of the Mg-H system was investigated. As the initial wt% of hydrogen was increased to 4.4, the peak temperature of evolution rate shifted to higher temperature. However, with the initial wt% of hydrogen higher than 4.4, peak temperature of evolution rate did not change. The peak temperatures of evolution rate obtained by automatic apparatus were almost the same as those measured by a manual apparatus. As the heating rate was increased, the peak temperatures increased; the peak temperatures for heating rates 1, 2 and 3 K/min were 664, 687 and 702 K, respectively. The activation energy for the decomposition of Mg hydride was 101 kJ/mol. The Sievert's type automatic apparatus can be successively applied to the thermal analysis of metal hydride.

Analysis of the spectral characteristics of white light-emitting diodes under various thermal environments

  • Jeong, Su-Seong;Ko, Jae-Hyeon
    • Journal of Information Display
    • /
    • v.13 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • An empirical functional form was suggested for the analysis of the emission spectrum of high-power light-emitting diode (LED) consisting of a sharp blue peak from the LED chips and a broad yellow peak from the phosphor layer. The peak positions, half widths, shape parameters, and amplitudes of these two peaks were reliably obtained as a function of the temperature, and the results were discussed qualitatively in relation with the junction temperature. The adoption of an inert liquid was found to have significantly reduced the LED temperature and the color shift of the emitted light. The phenomenological approach used in this study may be helpful in the simulation of the LED spectrum under various thermal conditions, and may thus be helpful in the improvement of the device performance.

Thermal Analysis of LaNi5 Hydride by Volumetric Method (부피법 자동장치를 이용한 LaNi5 수소화합물의 열분석 장치개발)

  • HAN, JEONG-SEB;KIM, SUNJUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.25-31
    • /
    • 2018
  • To apply Sievert's type apparatus to thermal analysis of hydrogen absorption materials, the dehydrogenation of $LaNi_5$ system was investigated. As the initial wt% of hydrogen was increased from 0.44 to 1.24 wt%, the peak temperature of evolution rate shifted to higher temperature. However, with the initial wt% of hydrogen higher than 0.95 wt%, the peak temperature of evolution rate did not change. As the heating rate was increased, the peak temperature increased; the peak temperatures for heating rates 0.5, 1.0 and 1.5 K/min were 262.2, 264.1, and 265.9 K respectively. The Sievert's type automatic apparatus can be successively applied to the thermal analysis of $LaNi_5$ hydride.

Development of Reduction Methods of Thermal Stresses Due to Hydration Heat (수화열에 의한 균열 저감 공법에 관한 연구)

  • Yang, Jo-Kyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1705-1710
    • /
    • 2008
  • In this paper, a program for simulating hydration heat and stresses was developed. And an effective methods were proposed for reduction of hydration heat stresses using flyash and steel fiber. It was shown that flyash replacement made reduction of peak temperature due to hydration heat. However, the effectiveness of reduction of tensile stress was not as good as it of peak temperature. Not only peak temperature but also tensile stress were reduced by the addition of steel fiber.

Effects of Thermal Properties and Water Retention Characteristics of Permeable Concrete Pavement on Surface Temperature (투.보수성 시멘트 콘크리트 포장의 열물성 및 수분보유특성이 표면온도에 미치는 영향)

  • Ryu Nam-Hyang;Yoo Byung-Rim
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.1 s.114
    • /
    • pp.21-36
    • /
    • 2006
  • This study was undertaken to analyze the effects of pavement thermal properties and water retention characteristics on the surface temperature of the gray permeable cement concrete pavement during the summer. Following is a summary of major results. 1) The hourly surface temperature of pavement could be well predicted with a heat transfer model program that incorporated the input data of major meteorological variables including solar radiation, atmospheric temperature, dew point, wind velocity, cloudiness and the evaporation rate of the pavements predicted by the time domain reflectometry (TDR) method. 2) When the albedo was changed to 0.5 from an arbitrary starting condition of 0.3, holding other variables constant, the peak surface temperature of the pavement dropped by 11.5%. When heat capacity was changed to $2.5\;kJm^{-3}K^{-1}\;from\;1.5\;kJm^{-3}K^{-1}$, surface temperature dropped by 8.0%. When daily evaporation was changed to 1 mm from 2 mm, temperature dropped by 5.7%. When heat conductivity was changed to $2.5\;Wm^{-1}K^{-1}\;from\;1.5\;Wm^{-1}K^{-1}$, the peak surface temperature of the pavement fell by 1.2%. The peak pavement surface temperature under the arbitrary basic condition was $24.46^{\circ}C$ (12 a.m.). 3) It accordingly became evident that the pavement surface temperature can be most effectively lowered by using materials with a high albedo, a high heat capacity or a high evaporation at the pavement surface. The glare situation, however, is intensified by raising of the albedo, moreover if reflected light is absorbed into surrounding physical masses, it is changed into heat. It accordingly became evident that raising the heat capacity and the evaporative capacity may be the moot acceptable measures to improve the thermal characteristics of the pavement. 4) The sensitivity of the surface temperature to major meteorological variables was as follows. When the daily average temperature changed to $0^{\circ}C\;from\;15^{\circ}C$, holding all other variables constant, the peak surface temperature of the pavement decreased by 56.1 %. When the global solar radiation changed to $200\;Wm^{-2}\;from\;600\;Wm^{-2}$, the temperature of the pavement decreased by 23.4%. When the wind velocity changed to $8\;ms^{-1}\;from\;4\;ms^{-1}$, the temperature decreased by 1.4%. When the cloudiness level changed to 1.0 from 0.5, the peak surface temperature decreased by 0.7%. The peak pavement surface temperature under the arbitrary basic conditions was $24.46^{\circ}C$ (12 a.m.)

A study on the structural changes and the TSC characteristics of epoxy composites cured with acid-anhydride (산무수물 경화된 에폭시 복합체의 구조변화와 TSC특성에 관한 연구)

  • 왕종배;이준웅
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.32-41
    • /
    • 1994
  • In this study, the TSC spectroscopy has been applied to investigate the influence of structural change due to a process of curing reaction on the electrical properties of epoxy composites cured with acid-anhydride. Five TSC peaks appeared in -160-250[.deg.C]: in the low temperature region below glass transition temperature(T$\_$g/), three relaxation mode peaks due to action of side chains, substitution group or terminal groups have been observed, a peak associated with T$\_$g/, appeared in 110[.deg. C] and p peak due to ionic space charges located in 150[.deg.C]. Each peak was separated into elementary peaks by the partial polarization procedure, and the distribution of activation energy and relaxation time were analized to clearify the origin of each peak. Also, overaboundantly added hardener separated a .betha. peak near 10[.deg. C] into two peaks of .betha.$\_$1/(10.deg. C) and .betha.$\_$2/(20.deg. C) according to increasement of forming field, and the separated hardener was oxidated thermally with increasing surrounding temperatures. The expansion of the free volume need in molecular motion and the reduction of the structural packing density through thermal oxidation process increased TSC between .alpha. peak and .betha. peak and decreased T$\_$g/.

  • PDF

Statistical Analyses of the Flowering Dates of Cherry Blossom and the Peak Dates of Maple Leaves in South Korea Using ASOS and MODIS Data

  • Kim, Geunah;Kang, Jonggu;Youn, Youjeong;Chun, Junghwa;Jang, Keunchang;Won, Myoungsoo;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.1
    • /
    • pp.57-72
    • /
    • 2022
  • In this paper, we aimed to examine the flowering dates of cherry blossom and the peak dates of maple leaves in South Korea, by the combination of temperature observation data from ASOS (Automated Surface Observing System) and NDVI (Normalized Difference Vegetation Index) from MODIS (Moderate Resolution Imaging Spectroradiometer). The more recent years, the faster the flowering dates and the slower the peak dates. This is because of the impacts of climate change with the increase of air temperature in South Korea. By reflecting the climate change, our statistical models could reasonably predict the plant phenology with the CC (Correlation Coefficient) of 0.870 and the MAE (Mean Absolute Error) of 3.3 days for the flowering dates of cherry blossom, and the CC of 0.805 and the MAE of 3.8 for the peak dates of maple leaves. We could suppose a linear relationship between the plant phenology DOY (day of year) and the environmental factors like temperature and NDVI, which should be inspected in more detail. We found that the flowering date of cherry blossom was closely related to the monthly mean temperature of February and March, and the peak date of maple leaves was much associated with the accumulated temperature. Amore sophisticated future work will be required to examine the plant phenology using higher-resolution satellite images and additional meteorological variables like the diurnal temperature range sensitive to plant phenology. Using meteorological grid can help produce the spatially continuous raster maps for plant phenology.

Regeneration of Burner Type Diesel Particulate Trap System Through Active Exhaust Gas Feeding (배기 가스 유량 제어를 이용한 버너방식 디젤 입자상물질 제거 장치의 재생)

  • 김재업;박동선;이만복;김응서
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 1997
  • The key point that guarantees the durability of the ceramic monolith filter is to lower peak temperature and temperature gradient inside filter during regeneration. The control of the exhaust gas flow rate into the filter, by the bypass technique of the exhaust gas, enables the gas temperature in filter to be constant for regeneration. A couple of methods, which are the ON/OFF and PID control of the bypass valve, were used for feedback control of the gas temperature. These techniques showed that the ceramic filter was regenerated perfectly under the peak temperature and peak temperature gradient limitations for durability.

  • PDF