• 제목/요약/키워드: Peak Detector

검색결과 323건 처리시간 0.025초

A Current-mode peak detector circuit

  • Riewruja, V.;Linthong, A.;Kaewpoonsuk, A.;Guntapong, R.;Supaph, S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.512-512
    • /
    • 2000
  • In this article, a current mode peak detector circuit is presented. The simple circuit configuration comprises four MOS transistors and one external capacitor. The realization method is suitable fur fabrication using CMOS technology and all transistors are operated in their saturation region. The proposed circuit exhibits a very low drop rate and provides high accuracy, high-speed and wide dynamic range. The proposed circuit has very low power dissipation and operates using a single 2.5V supply. Simulation results confirmed the characteristic of the proposed circuit are also included.

  • PDF

All-Synthesizable 5-Phase Phase-Locked Loop for USB2.0

  • Seong, Kihwan;Lee, Won-Cheol;Kim, Byungsub;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권3호
    • /
    • pp.352-358
    • /
    • 2016
  • A 5-phase phase-locked loop (PLL) for USB2.0 applications was implemented by using an all-synthesis technique. The length of the time-to-digital converter for the fine phase detector was halved by the operation of a coarse phase detector that uses 5-phase clocks. The maximum time difference between the rising edges of two adjacent-phase clocks was 6 ps at 480 MHz. The PLL chip in a 65-nm process occupies $0.038mm^2$, consumes 4.8 mW at 1.2 V. The measured rms and peak-to-peak output jitters are 8.6 ps and 45 ps, respectively.

PENELEOPE 시뮬레이션을 이용한 동축 HPGe 검출기의 거리 및 외부 접촉 층 두께 변화 연구 및 검증 (Research and Verification of Distance and Dead Thickness Changes of Coaxial HPGe Detectors using PENELEOPE Simulation)

  • 장은성;민병인
    • 한국방사선학회논문지
    • /
    • 제17권2호
    • /
    • pp.175-184
    • /
    • 2023
  • 검출기의 실제 모양과 제조사에서 제공한 데이터를 기준으로 Penelope simulation을 통해 검출기 모양을 구현하며 측정치에서 얻은 효율을 기준으로 하여 적합한 사층 두께에 적용하였다. 검출기의 simulation 된 전체에너지피크 효율 채널수와 crystal의 Outside contact layer가 전체에너지피크 효율에 미치는 영향을 결정 하기위한 효율 계산은 Penelope Code를 사용하여 0.3, 0.5, 0.7, 1.0, 1.2 ,1.4 mm의 다양한 사층 두께에 대해 수행하였다. 외부 접촉 사층 두께가 5배 증가하였을 때, 59.50 keV의 경우 전체에너지피크 효율이 약 36% 감소하였으며, 1836.01 keV 경우 10% 감소하였다. 또한 10배 증가할수록 59.54 keV의 경우 FEP 효율이 약 20% 감소하였으며, 1836.01 keV 경우 7% 감소하였음을 확인하였다. Penelope simulation된 전체에너지피크 효율 채널은 사층 증가에 따라 기하급수적으로 감소한다. 또한, 총 효과 곡선은 0.3 - 1.4 mm 사층 두께 영역에서 3.5% 미만의 상대적 차이로 잘 일치함을 확인하였다. 그러나 비균질 사층이 몬테카를로 모델에서 여전히 매개변수라는 것을 알 수 있었다.

A comparative study of ultra-trace-level uranium by thermal ionization mass spectrometry with continuous heating: Static and peak-jumping modes

  • Lee, Chi-Gyu;Park, Ranhee;Park, Jinkyu;Lim, Sang Ho
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1532-1536
    • /
    • 2020
  • For ensuring nuclear safeguards, we report the analytical signal-detection performance of thermal ionization mass spectrometry (TIMS) with continuous heating for the measurement of isotopic ratios in samples containing ultra-trace amounts of uranium. As methods for detecting uranium signals, peak-jumping mode using a single detector and static mode using multiple detectors were examined with U100 (10% 235U-enriched) uranium standard samples in the femtogram-to-picogram range. Uranium isotope ratios, n(235U)/n(238U), were measured down to levels of 1 fg and 3 fg in static and peak-jumping modes, respectively, while n(234U)/n(238U) and n(236U)/n(238U) values were measured down to levels of 100 fg in both modes. In addition, the dependency of the 238U signal intensity on sample quantity exhibited similar tendencies in both modes. The precisions of the isotope ratios obtained in the static mode over all sample ranges used in this study were overall slightly higher than those obtained in peak-jumping mode. These results indicate that isotope ratio measurements by TIMS with continuous heating are almost independent of the detection method, i.e., peak-jumping mode or static mode, which is characteristic of isotope-ratio measurements using the TIMS method with continuous heating. TIMS with continuous heating is advantageous as it exhibits the properties of multiple detectors within a single detector, and is expected to be used in various fields in addition to ensuring nuclear safeguards.

전 에너지 흡수 피크 분석용 GUI 기반 교육용 프로그램 개발 (A Development of GUI Full-Energy Absorption Peak Analysis Program for Educational Purpose)

  • 손종완;신명석;이혜정;정경수;정민수;김상년
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.69-75
    • /
    • 2009
  • 교육적 목적으로 감마선 검출기 계통의 특성에 대한 정보를 세밀하게 얻기 위하여, Delphi코드를 이용하여 전 에너지 흡수 피크 스펙트럼을 편리하게 분석할 수 있는 그래픽 사용자 인터페이스 방식의 컴퓨터 프로그램을 개발하였다. 피크는 4개의 비선형 모양함수를 사용하여 최소제곱법으로 적합하였다. 이들 4개의 비선형함수 속에 들어있는 12개의 계수값들을 사용자 인터페이스 화면에서 결정하는 과정을 상세히 서술하였다. 개발된 프로그램을 HPGe 검출기에서 측정된 1 $\mu$Ci 밀봉 점선원 $^{137)Cs$ 661KeV 감마선의 피크분석에 적용하여 계수값 탐색의 예를 예시하였다.

Analysis of Cationic Surfactants in Cosmetics By Reverse phase Ion-Pair Chromatigraphy with Suressed Conductivity Detector and UV Detector

  • Jong-Keun Choi;Jae
    • 대한화장품학회지
    • /
    • 제23권3호
    • /
    • pp.161-167
    • /
    • 1997
  • Determination of several cationic surfactants in cosmetics has been investigated. Reverse phase ion pair chromatography was used to identify and quantitate cationic surfactants. Cationic surfactants analyzed in this experiment were cetylpyridium chloride, stearyltrimetylammonium chloride, bezalkonium chloride, benzyldicethylcetylammonium chloride, and bihenyltrimethyl ammonium chloride. The separation was achieved on a reverse phase coumn with 10mM HCl-acetonitrile eluent. In this condition, the most of cationic surfactants with exception of CPC and CTAC respectively with suppressed conductivity detector and UV detector connected in series. The calibration curves obtained by plotting the peak areas of the cationic surfactants were linear at levels ranging from 0.005 to 0.1% correlation coefficient, r=0.9988. The detection limits were 1 to 5ppm in sample solution. The average recoveries of cationic surfactants added to hair treatment cream and hair rinse in three to five experiments were 96.7 105.2% and relative standard deviations were 1.1-3.8%. The case that there were CPC and CTAC in same solution was also tested. CPC and CTAC which couldn't be separated on reverse phase column were quantitated with suppressed conductivity detector and UV detector connected in series. Recovery of CPC and CTAC were 101.6 and 89.2% respectively. The proposed method was applied to the determination of cationic surfactants in commercial hair treatment cream.

  • PDF

이동통신용 RF 신호 검파기 설계 (A Design of the RF Signal Detector for Mobile Communication)

  • 안정식;김계국
    • 한국컴퓨터정보학회논문지
    • /
    • 제9권4호
    • /
    • pp.185-189
    • /
    • 2004
  • 본 논문에서는 이동통신 장치에 사용되는 다이오드 검파기와 로그 칩형 검파기를 설계하고 이를 서로 비교하여 그들의 용도를 명확히 제시하였다. 다이오드 검파기는 입력 신호의 세기 $-40dBm{\sim}-10dBm$의 변화에 대하여 $0{\sim}0.7V$의 검출 전압이 측정되었으며, 이것은 미세한 신호변화를 검출하기에 적합한 특성을 갖는다. 그리고 로그 칩형 검파기는 입력전력 $-65dBm{\sim}0dBm$의 변화에 대하여 $1.5V{\sim}4.5V$의 출력 전압을 얻었으며, 대체로 넓은 동작범위를 나타내고 있다. 따라서 로그 칩형 검파기는 넓은 입력 신호전력에 대하여 좁은 검출 전압이 측정되어, 그것의 감도가 둔감하게 나타나므로 피크전력 측정에 적합함을 알 수 있다.

  • PDF

식품포장재내 비휘발성 잠재 이행물질들의 스크리닝을 위한 이차원크로마토 그래피와 범용검출기의 이용 (The Use of the Online Two-dimensional Liquid Chromatography Coupled with a Universal Detector for the Screening of Non-volatile Potential Migrants in Food Packaging Materials)

  • 윤찬석;이근택
    • 한국포장학회지
    • /
    • 제16권1호
    • /
    • pp.9-18
    • /
    • 2010
  • For screening test of the non-volatile compounds which migrate from food packaging materials into foodstuffs, the traditional high performance liquid chromatography (HPLC) systems suffer from the lack of universal detector with high sensitivity and universality and high efficiency HPLC separation column which provides complete separation of complex mixtures into all individual substances. In this work, the use possibility of online two-dimensional liquid chromatography (2D-LC) system coupled with a charged aerosol detector (CAD), a universal detector, was reviewed. 2D-LC system permits to improve peak capacity and resolving power for complex mixtures. Charged aerosol detector (CAD) offers a new feasibility for detection of any non-volatile compounds with high sensitivity and constant response factor in a calibration range. The combination of size exclusion chromatography (SEC) and normal phase HPLC (NP-HPLC) is most frequently used for the separation of the natural and synthetic polymers which are mainly used as raw materials for the manufacture of food packaging materials. However, there is no commercial software available for data acquisition and handling and therefore the quantification in 2D-LC analysis is still rare.

  • PDF

Experimental and Simulated Efficiency of a HPGe Detector in the Energy Range of $0.06{\sim}11$ MeV

  • Park Chang Su;Sun Gwang Min;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.234-242
    • /
    • 2003
  • The full energy peak efficiency of a hyper pure germanium (HPGe) detector was calibrated in a wide energy range from 0.06 to 11 MeV. Both the experimental technique and the Monte Carlo method were used for the efficiency calibration. The measurement was performed using the standard radioisotopes in the low energy region of $60{\sim}1408$ keV, which was further extended up to 11 MeV by using the $^{14}N(n,r)\;and\;^{35}Cl(n,r)$ reactions. The GEANT Monte Carlo code was used for efficiency calculation. The calculated efficiency had the same dependency on the r-ray energy with the measurement, and the discrepancy between the calculation and the measurement was minimized by fine-tuning of the detector geometry. From the calculated result, the efficiency curve of the HPGe detector was reliably determined particularly in the high energy region above several MeV, where the number of measured efficiency points is relatively small despite the wide energy region. The calculated efficiency agreed with the measurement within about $7\%$. In addition to the efficiency calculation, the origin of the local minimum near 600 keV on the efficiency curve was analyzed as a general characteristics of a HPGe detector.

에너지 하베스팅 응용을 위한 진동 감지기가 있는 전파정류 회로 설계 (Design of a Full-Wave Rectifier with Vibration Detector for Energy Harvesting Applications)

  • 가학진;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.421-424
    • /
    • 2017
  • 본 논문에서는 진동 감지기가 있는 전파 정류 하베스팅 회로를 설계하였다. 설계된 회로는 진동 감지기와 능동다이오드를 통해 진동이 감지될 때에만 동작하며, 진동이 없을 때 비교기를 off시켜 $C_{STO}$에 저장된 에너지의 누설을 방지한다. 커패시터에 저장된 에너지는 레벨 변환기와 능동다이오드의 구동에 사용된다. 진동 감지기는 Hysteresis 기능이 있는 Schmitt Trigger와 피크검출기로 구현하였다. 제안된 회로는 $0.35{\mu}m$ CMOS 공정으로 설계하였으며, 모의실험을 통해 동작을 검증하였다. 설계된 에너지 하베스팅 회로의 칩 면적은 $590{\mu}m{\times}583{\mu}m$이다.

  • PDF