• 제목/요약/키워드: Peak Current-mode

검색결과 140건 처리시간 0.03초

양극산화에 의한 티타늄 산화막의 표면 특성 및 생체 활성에 관한 연구 (SURFACE CHARACTERISTICS AND BIOACTIVITY OF ANODICALLY OXIDIZED TITANIUM SURFACES)

  • 이상한;조인호
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.85-97
    • /
    • 2007
  • Statement of problem: Recently, anodic oxidation of cp-titanium is a popular method for treatment of titanium implant surfaces. It is a relatively easy process, and the thickness, structure, composition, and the microstructure of the oxide layer can be variably modified. Moreover the biological properties of the oxide layer can be controlled. Purpose: In this study, the roughness, microstructure, crystal structure of the variously treated groups (current, voltage, frequency, electrolyte, thermal treatment) were evaluated. And the specimens were soaked in simulated body fluid (SBF) to evaluate the effects of the surface characteristics and the oxide layers on the bioactivity of the specimens which were directly related to bone formation and integration. Materials and methods: Surface treatments consisted of either anodization or anodization followed thermal treatment. Specimens were divided into seven groups, depending on their anodizing treatment conditions: constant current mode (350V for group 2), constant voltage mode (155V for group 3), 60 Hz pulse series (230V for group 4, 300V for group 5), and 1000 Hz pulse series (400V for group 6, 460V for group 7). Non-treated native surfaces were used as controls (group 1). In addition, for the purpose of evaluating the effects of thermal treatment, each group was heat treated by elevating the temperature by $5^{\circ}C$ per minute until $600^{\circ}C$ for 1 hour, and then bench cured. Using scanning electron microscope (SEM), porous oxide layers were observed on treated surfaces. The crystal structures and phases of titania were identified by thin-film x-ray diffractmeter (TF-XRD). Atomic force microscope (AFM) was used for roughness measurement (Sa, Sq). To evaluate bioactivity of modified titanium surfaces, each group was soaked in SBF for 168 hours (1 week), and then changed surface characteristics were analyzed by SEM and TF-XRD. Results: On basis of our findings, we concluded the following results. 1. Most groups showed morphologically porous structures. Except group 2, all groups showed fine to coarse convex structures, and the groups with superior quantity of oxide products showed superior morphology. 2. As a result of combined anodization and thermal treatment, there were no effects on composition of crystalline structure. But, heat treatment influenced the quantity of formation of the oxide products (rutile / anatase). 3. Roughness decreased in the order of groups 7,5,2,3,6,4,1 and there was statistical difference between group 7 and the others (p<0.05), but group 7 did not show any bioactivity within a week. 4. In groups that implanted ions (Ca/P) on the oxide layer through current and voltage control, showed superior morphology, and oxide products, but did not express any bioactivity within a week. 5. In group 3, the oxide layer was uniformly organized with rutile, with almost no titanium peak. And there were abnormally more [101] orientations of rutile crystalline structure, and bonelike apatite formation could be seen around these crystalline structures. Conclusion: As a result of control of various factors in anodization (current, voltage, frequency, electrolytes, thermal treatment), the surface morphology, micro-porosity, the 2nd phase formation, crystalline structure, thickness of the oxide layer could be modified. And even more, the bioactivity of the specimens in vitro could be induced. Thus anodic oxidation can be considered as an excellent surface treatment method that will able to not only control the physical properties but enhance the biological characteristics of the oxide layer. Furthermore, it is recommended in near future animal research to prove these results.

디스플레이 융합 기술 개발을 위한 32 × 32 광양자테 레이저 어레이의 특성 (Characteristics of 32 × 32 Photonic Quantum Ring Laser Array for Convergence Display Technology)

  • 이종필;김무진
    • 한국융합학회논문지
    • /
    • 제8권5호
    • /
    • pp.161-167
    • /
    • 2017
  • 상온에서 단일소자의 경우 $0.98{\mu}A$ 문턱전류를 나타내는 $32{\times}32$ 광양자테 레이저 어레이를 제작하였다. 제작된 어레이의 전체 소자들의 문턱전류 및 밀도, 전압은 20 mA, $0.068A/cm^2$, 1.38 V의 값을 나타내었다. 발광 광양자테 어레이는 GaAs 물질이 다중-양자 우물 활성 영역을 구성하고, 칩이 차지하는 면적은 $1.65{\times}1.65mm^2$였으며, 소자들의 피크파워 파장은 $858.8{\pm}0.35nm$, 상대적인 레이저 세기는 $0.3{\pm}0.2$, 선폭은 $0.2{\pm}0.07nm$로 비교적 균일한 특성을 보였다. 또한, 레이저 어레이의 각도 의존적 청색 이동 특성을 이용한 파장 분할 멀티플렉싱 시스템 실험을 진행하였고, 각도에 따라 10 nm 정도 파장이 변하는 현상을 발견하였으며, 거리에 따른 레이저 세기를 측정한 결과 6 m에서도 감지할 수 있음을 확인하였다.

마이크로폰의 위치에 따른 중량 바닥충격음레벨의 편차 (Deviation of Heavy-Weight Floor Impact Sound Levels According to Measurement Positions)

  • 오양기;주문기;박종영;김하근;양관섭
    • 한국음향학회지
    • /
    • 제25권2호
    • /
    • pp.49-55
    • /
    • 2006
  • 현행 중량 바닥충격음 표준 측정방식인 KS F 2810-2에 의하면 중앙점을 포함한 3-5곳의 타격위치에 대하여 수음실에서 4곳 이상의 지점의 피크레벨을 측정하도록 되어있다. 그러나 이 표준 방식에 의한 동일 상황에서의 측정 결과가 측정기관, 측정횟수, 측정점의 위치 등에 따라 일관성을 보이지 못하고 있음이 종종 발견된다. 이러한 편차는 반복성이나 재현성의 측면에서 측정값의 신뢰도에 영향을 미칠 수 있는 수준으로 우려된다. 측정결과 실험실의 경우 중앙 타격시 63Hz 대역에서 각 지점간의 차이가 l0dB이상 차이를 보였으며, 전체적으로 중간주파수 대역에서 보다 저주파수 대역에서의 편차가 크게 발생하는 것으로 나타났다. 이러한 편차는 저주파수 대역에서의 모드 중첩현상에 의한 것으로 보인다. 현행 바닥충격음 단일지수 평가 방법에 따라 평가한 결과 측정위치에 따라 단일지수 평가값에 2-7dB의 차이를 보였으며 바닥충격음 차음성능 평가에 영향을 줄 수 있을 것으로 판단되었다. 따라서 향후 저주파 대역의 편차를 줄이거나 저음의 모드 중첩에 의한 영향을 배제할 수 있는 측정 혹은 평가 방식의 개선이 필요하다고 사료된다.

Effect of loading velocity on the seismic behavior of RC joints

  • Wang, Licheng;Fan, Guoxi;Song, Yupu
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.665-679
    • /
    • 2015
  • The strain rate of reinforced concrete (RC) structures stimulated by earthquake action has been generally recognized as in the range from $10^{-4}/s$ to $10^{-1}/s$. Because both concrete and steel reinforcement are rate-sensitive materials, the RC beam-column joints are bound to behave differently under different strain rates. This paper describes an investigation of seismic behavior of RC beam-column joints which are subjected to large cyclic displacements on the beam ends with three loading velocities, i.e., 0.4 mm/s, 4 mm/s and 40 mm/s respectively. The levels of strain rate on the joint core region are correspondingly estimated to be $10^{-5}/s$, $10^{-4}/s$, and $10^{-2}/s$. It is aimed to better understand the effect of strain rates on seismic behavior of beam-column joints, such as the carrying capacity and failure modes as well as the energy dissipation. From the experiments, it is observed that with the increase of loading velocity or strain rate, damage in the joint core region decreases but damage in the plastic hinge regions of adjacent beams increases. The energy absorbed in the hysteresis loops under higher loading velocity is larger than that under quasi-static loading. It is also found that the yielding load of the joint is almost independent of the loading velocity, and there is a marginal increase of the ultimate carrying capacity when the loading velocity is increased for the ranges studied in this work. However, under higher loading velocity the residual carrying capacity after peak load drops more rapidly. Additionally, the axial compression ratio has little effect on the shear carrying capacity of the beam-column joints, but with the increase of loading velocity, the crack width of concrete in the joint zone becomes narrower. The shear carrying capacity of the joint at higher loading velocity is higher than that calculated with the quasi-static method proposed by the design code. When the dynamic strengths of materials, i.e., concrete and reinforcement, are directly substituted into the design model of current code, it tends to be insufficiently safe.

폐 피복관 처리를 위한 염소계-불소계 혼합용융염 내 지르코늄 전해정련공정에서 삼불화알루미늄의 효과 연구 (Effect of AlF3 on Zr Electrorefining Process in Chloride-Fluoride Mixed Salts for the Treatment of Cladding Hull Wastes)

  • 이창화;강덕윤;이성재;이종현
    • 방사성폐기물학회지
    • /
    • 제17권2호
    • /
    • pp.127-137
    • /
    • 2019
  • 삼불화알루미늄($AlF_3$)이 포함된 염화물-불화물 혼합 용융염에서 ZIRLO 튜브를 이용한 지르코늄 전해정련공정을 실증하였다. 순환 전압전류실험 결과, $AlF_3$의 농도가 증가함에 따라 금속환원의 개시 전위가 일정하게 증가하고 지르코늄-알루미늄 합금형성과 관련된 추가적인 peak의 크기가 점차 증가하는 것으로 나타났다. 전류조절 전착법과 달리, -1.2 V의 일정전위에서 수행한 지르코늄 전해정련에서 방사형 판 구조의 지르코늄 성장이 염의 상단 표면에서 확연하게 나타났으며, 전착물 지름의 크기는 $AlF_3$의 농도에 따라 점차 증가하는 것으로 나타났다. 주사전자현미경(SEM)과 에너지 분산 X선 분광기(EDX)와 X선 광전자 분광기(XPS)를 이용하여 판 구조의 지르코늄 전착물을 분석한 결과, 극미량의 알루미늄이 지르코늄-알루미늄 합금 형태로 존재하며, 전착물의 상단과 하단 간에 서로 다른 화학성분구조를 갖는 것으로 나타났다. $AlF_3$의 첨가는 전착물 내 잔류염 양을 줄이고, 지르코늄 회수를 위한 전류효율을 향상시키는 데 효과적인 것으로 나타났다.

InAs 양자점 형성 방법이 양자점 적외선 소자 특성에 미치는 효과 (Effect of Growth Methods of InAs Quntum Dots on Infrared Photodetector Properties)

  • 서동범;황제환;오보람;노삼규;김준오;이상준;김의태
    • 한국재료학회지
    • /
    • 제28권11호
    • /
    • pp.659-662
    • /
    • 2018
  • We report the properties of infrared photodetectors based on two kinds of quantum dots(QDs): i) 2.0 ML InAs QDs by the Stranski-Krastanov growth mode(SK QDs) and ii) sub-monolayer QDs by $4{\times}[0.3ML/1nm\;In_{0.15}Ga_{0.85}As]$ deposition(SML QDs). The QD infrared photodetector(QDIP) structure of $n^+-n^-(QDs)-n^+$ is epitaxially grown on GaAs (100) wafers using molecular-beam epitaxy. Both the bottom and top contact GaAs layers are Si doped at $2{\times}10^{18}/cm^3$. The QD layers are grown with Si doping of $2{\times}10^{17}/cm^3$ and capped by an $In_{0.15}Ga_{0.85}As$ layer at $495^{\circ}C$. The photoluminescence peak(1.24 eV) of the SML QDIP is blue-shifted with respect to that (1.04 eV) of SK QDIPs, suggesting that the electron ground state of SML QDIP is higher than that of the SK QDIP. As a result, the photoresponse regime(${\sim}9-14{\mu}m$) of the SML QDIP is longer than that (${\sim}6-12{\mu}m$) of the SK QDIP. The dark current of the SML QDIP is two orders of magnitude smaller value than that of the SK QDIP because of the inserted $Al_{0.08}Ga_{0.92}As$ layer.

Improved Device Performance Due to AlxGa1-xAs Barrier in Sub-monolayer Quantum Dot Infrared Photodetector

  • Han, Im Sik;Byun, Young-Jin;Lee, Yong Seok;Noh, Sam Kyu;Kang, Sangwoo;Kim, Jong Su;Kim, Jun Oh;Krishna, Sanjay;Ku, Zahyun;Urbas, Augustine;Lee, Sang Jun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.298-298
    • /
    • 2014
  • Quantum dot infrared photodetectors (QDIPs) based on Stranski-Krastanov (SK) quantum dots (QDs) have been widely explored for improved device performance using various designs of heterostructures. However, one of the biggest limitations of this approach is the "pancake" shape of the dot, with a base of 20-30 nm and a height of 4-6 nm. This limits the 3D confinement in the quantum dot and reduces the ratio of normal incidence absorption to the off-axis absorption. One of the alternative growth modes to the formation of SK QDs is a sub-monolayer (SML) deposition technique, which can achieve a much higher density, smaller size, better uniformity, and has no wetting layer as compared to the SK growth mode. Due to the advantages of SML-QDs, the SML-QDIP design has attractive features such as increased normal incidence absorption, strong in-plane quantum confinement, and narrow spectral wavelength detection as compared with SK-DWELL. In this study, we report on the improved device performance of InAs/InGaAs SML-QDIP with different composition of $Al_xGa1-_xAs$ barrier. Two SML-QDIPs (x=0.07 for sample A and x=0.20 for sample B) are grown with the 4 stacks 0.3 ML InAs. It is investigated that sample A with a confinement-enhanced (CE) $Al_{0.22}Ga_{0.78}As$ barrier had a single peak at $7.8{\mu}m$ at 77 K. However, sample B with an $Al_{0.20}Ga_{0.80}As$ barrier had three peaks at (${\sim}3.5{\mu}m$, ${\sim}5{\mu}m$, ${\sim}7{\mu}m$) due to various quantum confined transitions. The measured peak responsivities (see Fig) are ~0.45 A/W (sample A, at $7.8{\mu}m$, $V_b=-0.4V$ bias) and ~1.3 A/W (sample B, at $7{\mu}m$, $V_b=-1.5V$ bias). At 77 K, sample A and B had a detectivity of $1.2{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-0.4V$ bias) and $5.4{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-1.5V$ bias), respectively. It is obvious that the higher $D^*$ of sample B (than sample A) is mainly due to the low dark current and high responsivity.

  • PDF

64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소 (Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols)

  • 김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.299-306
    • /
    • 2009
  • MDCT의 시간분해능 향상과 등방성 해상능(isotrophic resolution) 영상의 획득, 그리고 지능적인 심전도 동조를 바탕으로 하여 심혈관 질환의 효과적인 진단검사로 인정받고 있는 후향적 심전도 동조화(retrospective ECG gating) 하의 coronary CT angiography는 상대적으로 많은 환자선량을 제공함으로 인해 우수한 진단방법으로서의 장점을 반감시키고 있다. 이에 각 장치 제조사에서는 환자선량을 감소시키는 방법의 연구가 활성화되어 왔으며, 이의 일환으로 지능적인 cardiac dose modulation 기술과 전향적 심전도 동조화(prospective ECG gating)를 사용한 sequential scan이 도입되고 있다. 이에 본 연구에서는 64 채널 MDCT에서 54 kg, 163 cm인 여성 인체모형팬텀을 대상으로 하고 형광유리선량계를 사용하여 후향적 심전도 동조화 하의 coronary CT angiography 프로토콜에서 환자선량의 정량적 평가와 환자선량 감소를 위해 본원에서 선택적으로 적용하고 있는 5가지 검사 프로토콜을 적용하였을 경우의 effective dose와 중요 부위의 organ dose를 측정 비교하여 다음과 같은 결과를 얻었다. 1) Dose modulation없이 120 kVp와 210 mAs의 노출조건으로 retrospectively ECG gated helical scan으로 시행한 conventional coronary CT angiography 프로토콜의 effective dose는 17.8 mSv였으며, 심장의 organ dose는 103.8 mGy였다. 2) 관전압을 120 kVp에서 100 kVp로 낮추었을 경우 effective dose는 11.0 mSv로 conventional coronary CT에 비해 38.2%가 감소하였으며, 심장은 67.3 mGy로 45.2%가 감소하였다. 3) Cardiac dose modulation을 적용한 경우 effective dose는 13.3 mSv로 conventional coronary CT에 비해 25.3%가 감소하였으며, 심장은 80.0 mGy로 22.9%가 감소하였다. 4) 100 kVp의 저관전압과 cardiac dose modulation을 적용한 경우 effective dose는 8.1 mSv로 conventional coronary CT angiography에 비해 54.5%가 감소하였으며, 심장은 49.5 mGy로 52.3%가 감소하였다.

  • PDF

가정용 인공호흡기를 사용하는 서울 및 경기 지역 환자의 실태 (Survey of Current Status of the Patients with Home Ventilator in Seoul and Kyunggi Province)

  • 안종준;이기만;심태선;임채만;이상도;김우성;김동순;김원동;고윤석
    • Tuberculosis and Respiratory Diseases
    • /
    • 제49권5호
    • /
    • pp.624-632
    • /
    • 2000
  • 서론 : 최근 발달된 기술로 작고 기능이 뛰어난 가정용 인공호흡기가 개발되어 구미에서는 장기간 기계환기가 필요한 만성호흡부전 환자를 대상으로 그 사용아 점차 보편화 되어 가고 있다. 우리나라에서도 가정에서 기계환기치료의 적용이 최근 확산되고 있으나 이 치료법에 대한 임상 경험 보고나 그 실태 조사 자료가 거의 없어 이에 대한 기초 자료의 조사가 필요한 상태이다. 본 연구는 장기간 기계환기 보조가 필요하여 가정용 인공호흡기를 사용하는 환자에서 간호 관리의 문제점과 가정용 인공호흡기 사용 실태를 조사하기 위하여 연구를 시행하였다. 연구대상 및 방법 : 서울 및 경기 지역에서 가정용 인공호흡기를 사용하고 있는 환자 92명의 명단을 인공호흡기를 공급 관리하는 업체에서 제공 받아 전화 통화를 시도하여 방문에 동의하는 29명을 대상으로 하였다. 대상 환자의 집을 방문하여 병력 청취와 신체 검사를 시행하였고, 환자 간호 관리에 대한 설문을 실시하였다. 설문의 내용에는 간호 관리에 대한 사전 교육 여부, 의료인의 가정 방문 여부, 인공호흡기 이상의 경험 여부, 인공호흡기 및 부가 장비의 구입 경비, 환자 간호와 연관된 문제점 및 개선을 위한 제안 등이 포함되어 있었다. 가정용 인공호흡기의 설정 요소들을 확인하고, 측정되는 일회호흡용적(tidal volume), 최대 기도압, 산소포화도 등을 기록하였다. 연구결과 : 1) 방문을 마친 환자 29명중 남자는 26명(90%)이었고, 나이는 48.0(${\pm}$20.1)세였다. 환자들의 기저 질환은 신경근 질환 21명(72.4%), 척수 손상 2명(6.9%), 만성 폐질환 6명(20.7%)이었다. 2) 간호 관리자는 배우자가 14명(48.3%)으로 가장 많았으며, 가정 간호 관리를 위한 사전 교육은 주로 입원 중 간호사로부터 배우고 있었다. 3) 인공호흡기를 구입하여 사용하는 경우는 23명으로 압력달성양식(pressure targeted type)은 745(${\pm}$329)만원, 용적달성양식(volume targeted type)은 1,428(${\pm}$313)만원이 각각 소요되었다. 장비 구입에 소요되는 총 비용은 1,13l(${\pm}$653)만원이었다. 환자를 간호 관리하는데 1개월간 소요되는 평균 비용은 112(${\pm}$136)만원이었다. 4) 29명의 환자 중 25명 (86%)은 기관절개술을 시행한 상태로 기계환기를 시행하고 있었다. 인공호흡기는 용적달성양식이 20명(69%)으로 압력달성양식(9명, 31%)보다 더 많았다. 결론 : 우리나라에서 가정용 인공호흡기를 사용하는 환자는 신경근 질환 환자가 가장 많았고, 대부분 기관절개술을 시행한 상태로 경보 기능을 가진 용적달성양식을 많이 사용하고 있었다. 환자와 가족들은 장비 구입 및 유지와 연관된 경제적인 어려움을 당연한 문제로 제시 하였으며 환자들 중 일부는 가정간호사들의 도움을 받고 있었으나 의사들의 지속적인 감시를 받지 못한 채 방치되어 있었다.

  • PDF

허규 연출 '완판 창극'의 특징과 의의 (The Characteristics and Significance of 'Wanpan Changgeuk' Written by Heogyu)

  • 김기형
    • 공연문화연구
    • /
    • 제20호
    • /
    • pp.5-30
    • /
    • 2010
  • 허규는 80~90년대 창극 연출을 담당하며 왕성한 활동을 전개한 바 있다. 그는 전승 5가 뿐만 아니라 실전 판소리를 창극화 하였으며, 창작 창극 작품도 다수 무대에 선보였다. 특히 '완판 창극'이라는 이름으로 1982년 <흥보전>을 무대에 올린 후 1985년 <적벽가>를 공연함으로써 전승 5가의 창극화 작업을 완결지은 것은 그가 남긴 큰 업적 가운데 하나이다. 허규는 주체적 민족문화의 정립과 한국 전통연희의 창조적 계승 문제에 많은 관심을 기울였던 실천적인 연극인이다. 그는 창극을 한국의 대표적인 공연예술로 정립하고자 노력했다. 창극 작품은 그 연원에 따라, (1)전승 5가의 창극화 (2)실전 7가의 창극화 (3)창작 창극으로 세분해 볼 수 있다. 허규가 연출한 작품에는 이 3가지 유형이 모두 포함되어 있다. 그 가운데 전승 5가를 창극화한 작품이 가장 큰 비중을 차지하고 있다. 허규가 시도한 '완판창극'은 한국의 전통유산 가운데 빼어난 예술적 성과를 거둔 요소들을 집대성하여 무대에 올림으로써, 창극을 한국의 대표적인 공연예술로 정립해 보고자한 것이다. '완판창극'에 나타난 특징은 다음 네 가지로 정리할 수 있다. (1) 전통을 중시하는 연출 태도, (2) 전통연희 요소의 적극적 수용, (3) 격조와 윤리의식의 중시, (4) 해학의 강조와 보조인물의 적극적 활용이 그것이다. 허규가 시도한 '완판창극'은 창극이 성취할 수 있는 예술적 수준의 한 정점을 보여주는 것이다. 판소리 유산을 망라하고 나아가 전통연희를 적극적으로 수용하여, 창극을 한국의 대표적인 공연예술로 정립해 보고자 했던 것이다. 허규는 '완판창극'에서 판소리의 진정성을 그대로 살리려고 노력했으며, 처음부터 끝까지 한 대목도 빠뜨리지 않고 장면화 하려고 했다. '완판창극'의 공연 시간이 4~5시간이나 소요되었다는 것이 그 점을 잘 보여준다. 허규가 완판창극에서 거둔 성과는 이후 창극에 상당한 영향을 끼친 것으로 보인다. 1990년대에 시도된 '완판장막창극'도 그 모태는 허규의 '완판창극'에 두고 있다. 창본을 종합해 내고 판소리의 좋은 점을 모두 보여주고자 하는 의도가 일치한다는 점에서 특히 그러하다. 그렇지만 90년대 '완판장막창극'은 대형 무대화를 지향했으며 화려한 무대장치와 의상 그리고 버라이어티한 요소를 부각시켰다는 점에서 '완판창극'과 대비된다. 허규의 완판창극이 끼친 중요한 영향 가운데 하나는 판소리의 '열린 형식'을 창극의 공연 문법으로 적극 활용했다는 점이다. 허규는 극의 전개 과정에서 필요하다고 판단되면 전통연희의 요소를 적극적으로 수용하여, 극적 표현 영역을 확장하고 작품의 완성도를 높이고자 했다. 이러한 그의 시도는 창극 극작술의 한 방식으로 인식되어, 이후 창극연출에도 지속적으로 영향을 미치고 있다. 요즘 창극은 어떻게 하면 청중들의 호응을 얻을 수 있을까에 관심을 집중하기 때문에, '감동받는 창극' 보다는 '재미있는 창극'을 만드는 일이 중요하다고 생각하는 듯하다. 공연 시간도 최대 2시간을 넘지 않으려고 하며, 관현악 반주를 중시하는 경향을 보여준다. 이런 관점에서는 허규가 '완판창극'을 통해 구현하고자 했던 창극의 지향점은 극복의 대상으로 인식되고 있는 것으로 보인다.