• Title/Summary/Keyword: Passive and Active

Search Result 2,172, Processing Time 0.125 seconds

Development of the Hybrid EMI Filter for DC-DC Converter (DC-DC 전력변환장치용 Hybrid EMI 필터 개발)

  • Lee, Dong-Ho;Yoo, Jin-Wan;Park, Chong-Yeun
    • Journal of Industrial Technology
    • /
    • v.34
    • /
    • pp.71-78
    • /
    • 2014
  • Recently, using the electronic devices was increased with semiconductor developments. So, the EMI(Electromagnetic interference) problem become to important issue for coexistence with each electronic devices. The EMI is caused by switching operation from the power switches as the FET and the transistor in power conversion devices. In this paper, the hybrid EMI filter that composed with active components and passive components was described. The EMI filter is applied to the 160 watts LED driver experimentally verify the performance. The hybrid EMI filter is compared with non-filter, only passive filter and only active filter. The proposed EMI filter attenuated CM noise more than traditional passive filter.

  • PDF

Children's Personality Traits, Parent Attachment, Parents' Marital Conflict, and Aggression/victimization Status (또래괴롭힘 집단에 따른 아동의 인성특성, 부모에 대한 애착 및 부모의 부부갈등)

  • 박보경;한세영;최미경;도현심
    • Journal of Families and Better Life
    • /
    • v.22 no.1
    • /
    • pp.45-54
    • /
    • 2004
  • To examine group differences among four groups divided by asgression/victimization status, 655 4th graders living in Seoul reported their perceptions of peer aggression, peer victimization, personality traits, parent attachment, and their parents' marital conflict. Peers of the subjects also reported their perceptions of peer aggression and peer victimization. Based on the scores of peer aggression and peer victimization, each child was classified into one of the four groups: nonvictimized aggressors, aggressive victims, passive victims, and normative contrasts. For boys, nonvictimized aggressors were more sociable/active than both aggressive and passive victims. Aggressive victims were more shy/emotional than nonvictimized aggressors and normative contrasts, and were exposed to the highest parental marital conflict. For girls, passive victims were the least sociable/active among the four groups, and showed lower attachment to fathers than normative contrasts. Both aggressive and passive victims were more shy/emotional than nonvictimized aggressors and normative contrasts, and normative contrasts were exposed to the lowest parental marital conflict.

Design of active intelligent decision support system for investment evaluation

  • 조현석;서의호
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.10a
    • /
    • pp.214-217
    • /
    • 1996
  • Early decision support systems (DSS) were the "passive" decision support systems in the sense that the systems only able to do what the users explicitly direct them to do. But some researchers such as Raghav Rao et al. [51 showed architectures to suggest general idea of the innovative DSS systems which offer active form of decision support, say, "active Intelligent Decision Support Systems(active IDSS)". The system can perform not only what the users want to do but some voluntary (or involuntary) intelligent works. This paper presents the issues in the design of the active IDSS in the domain of investment evaluation, a domain area where few researchers have suggested frameworks or architectures to discriminate good investment from bad one. We propose a new paradigm, by utilizing historical investment results using neural network and Multivariate Discriminant Analysis(MDA), to identify goodness of investment. A new active IDSS architecture which consists of neural network, expert system and three components of the traditional passive DSS is suggested with some scenario based results.nario based results.

  • PDF

Study on Active Damper System Applying DC-Motor (DC Motor를 이용한 능동형 댐퍼 시스템에 대한 연구)

  • Lee, Hak-Cheol;Jeon, Jin-Young;Jeong, Young-Suk
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.121-123
    • /
    • 2008
  • The suspension systems currently in use can be classified as passive, semi-active and active. The passive suspension systems are the most commonly used due their low price and high reliability. However, this system cannot assure the desired performance form a modern suspension system. An important improvement of suspension performance is achieved by the active systems. This paper treats active damper system and applying DC-Motor. In this system, all the energy for active control is supplied from the damper, which regenerates energy. And simulations by sky-hook control.

  • PDF

Complete decentralized displacement control algorithm

  • Ruiz-Sandoval, M.E.;Morales, E.
    • Smart Structures and Systems
    • /
    • v.11 no.2
    • /
    • pp.163-183
    • /
    • 2013
  • Control systems have been greatly studied in recent years and can be classified as: passive, active, semi-active or hybrid systems. Most forms of control systems have been applied in a centralized manner where all the information is sent to a central node where control the algorithm is then calculated. One of the possible problems of centralized control is the difficulty to scale its application. In this paper, a completely decentralized control algorithm is analytically implemented. The algorithm considers that each of the control systems makes the best decision based solely on the information collected at its location. Semi-active control is used in preference to active control because it has minimal energy consumption, little to no possibility of destabilization, a reduction in the possibility of data saturation, and a reduction in the response time in comparison to centralized control.

Strain Distribution of Transition Zone in a Nail Wall (네일로 보강된 구조물에서의 변이영역과 변형률 분포)

  • Chang, Ki-Tae;NamGung, Han;Yoo, Byung-Sun
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.1
    • /
    • pp.39-43
    • /
    • 2005
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are 'active zone' and 'passive zone'. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain istribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

Sound Control of Structural-acoustic Coupling System Using Optimum Layout of Absorbing Material and Damping Material (흡음재 및 제진재의 최적배치를 이용한 구조-음향 연성계의 소음제어)

  • Kim, Dong-Young;Hong, Do-Kwan;Ahn, Chan-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.2 s.95
    • /
    • pp.161-168
    • /
    • 2005
  • The absorbing material is mostly used to changing the acoustic energy to the heat energy in the passive control, and that consists of the porous media. That controls an air borne noise while the stiffened plates, damping material and additional mass control a structure borne noise. The additional mass can decrease the sound by mass effect and shift of natural frequency, and damping material can decrease the sound by damping effect. The passive acoustic control using these kinds of control materials has an advantage that is possible to control the acoustic in the wide frequency band and the whole space at a price as compared with the active control using the various electronic circuit and actuator. But the space efficiency decreased and the control ability isn't up to the active control. So it is necessary to maximize the control ability in the specific frequency to raise the capacity of passive control minimizing the diminution of space efficiency such an active control. Therefore, the characteristics of control materials and the optimum layout of control materials that attached to the boundary of structure-acoustic coupled cavity were studied using sequential optimization on this study.

Nonlinear semi-active/passive retrofit design evaluation using incremental dynamic analysis

  • Rodgers, Geoffrey W.;Chase, J. Geoffrey;Roland, Thomas;Macrae, Gregory A.;Zhou, Cong
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.109-120
    • /
    • 2022
  • Older or damaged structures can require significant retrofit to ensure they perform well in subsequent earthquakes. Supplemental damping devices are used to achieve this goal, but increase base shear forces, foundation demand, and cost. Displacement reduction without increasing base shear is possible using novel semi-active and recently-created passive devices, which offer energy dissipation in selected quadrants of the force-displacement response. Combining these devices with large, strictly passive energy dissipation devices can offer greater, yet customized response reductions. Supplemental damping to reduce response without increasing base shear enables a net-zero base shear approach. This study evaluates this concept using two incremental dynamic analyses (IDAs) to show displacement reductions up to 40% without increasing base shear, more than would be achieved for either device alone, significantly reducing the risk of response exceeding the unaltered structural case. IDA results lead to direct calculation of reductions in risk and annualized economic cost for adding these devices using this net-zero concept, thus quantifying the trade-off. The overall device assessment and risk analysis method presented provides a generalizable proof-of-concept approach, and provides a framework for assessing the impact and economic cost-benefit of using modern supplemental energy dissipation devices.

Antigenicity Test of Bovine Somatorophin(BST) in Guinea pigs and Rabbits (기니픽과 토끼에서 소성장 홀몬(BST)의 항원성에 관한 시험)

  • 강경선;이영순
    • Journal of Food Hygiene and Safety
    • /
    • v.6 no.3
    • /
    • pp.179-183
    • /
    • 1991
  • Antigenicity tests-ASA(Active Systemic Anaphylaxis), PSA(Passive Systemic Anaphylaxis), PCA(Passive Cutaneous Anaphylaxis)- of Bovine Somatotrophine(BST, Lucky Ltd.) were performed according to the established regulations of National Institude of Safety Research. The results were as follows: 1. No specific clinical signs related anaphylaxis were observed. Therefore, it was considered that BST has no antigenicity in guinea pigs and rabbits. 2. No blue spots were observed on the back of guinea pig in the peA test; BST-related IgE was not produced.

  • PDF

Study of Design Strategy to Reduce Energy Consumption in a Standard Office Building (사무용 건물의 에너지 절감을 위한 요소별 성능 분석 및 디자인 전략에 관한 연구)

  • Yang, Ja-Kang;Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.23-31
    • /
    • 2016
  • Purpose: Recently energy consumption is rapidly increasing due to continuous development of social evolution in various field. In this situation, there is a lot of effort to reduce this energy consumption in many ways, especially in building energy. Preceding studies already started to analyze the housing area such as zero energy house and passive house by researching annual building energy consumption, but to apply the results of housing to office building is insufficient since it has different consumption tendency. Method: In this study, eQuest program was used for simulation and the base model is selected among standard office building in ASHRAE 90.1. Variables are divided into passive and active factors for comparison. Result: In passive factors, glazing system showed the highest energy saving rate by 21.3% with triple low-e glass and enhancing wall u-value showed the lowest energy saving rate by 3.6% with 0.15 m2/K. In active factors, VAV system showed 30.9% energy saving rate when compared to CAV system, and heat exchanger showed 10.2% energy saving rate. For regeneration energy part, photovoltaic panel generated 10.4% of base annual energy usage.