• Title/Summary/Keyword: Passive Resistance

Search Result 327, Processing Time 0.027 seconds

Evaluation of Electrochemical Corrosion Characteristics for Hot-Dip Aluminized 304 Stainless Steel in Seawater (알루미늄 용융 도금된 304 스테인리스강의 해수 내 전기화학적 부식 특성 평가)

  • Chong, Sang-Ok;Park, Il-Cho;Han, Min-Su;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.354-359
    • /
    • 2015
  • Stainless steel has poor corrosion resistance in marine environment due to the breakdown of a passive film caused by chloride. It suffers electrochemical corrosion like pitting corrosion, crevice corrosion, and stress corrosion crack (SCC) in marine environment. In general, it indicates that the passive film of $Al_2O_3$ has better corrosion resistance than that of $Cr_2O_3$ in seawater. This paper investigated the damage behavior 304 stainless steel and hot-dip aluminized 304 stainless steel in seawater solution. Various electrochemical experiments were carried out including potential measurement, potentiodynaimic experiment, Tafel analysis and galvanostatic experiment. As a result of anodic polarization experiment, higher pitting damage depth was indicated at 304 stainless steel than hot-dip aluminized 304 stainless steel. In addition, relatively higher corrosion current density was shown at hot-dip aluminized stainless steel as a result of Tafel analysis.

Electrochemical Corrosion Damage Characteristics of Aluminum Alloy Materials for Marine Environment (해양환경용 알루미늄 합금 재료의 전기화학적 부식 손상 특성)

  • Kim, Sung Jin;Hwang, Eun Hye;Park, Il-Cho;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.6
    • /
    • pp.421-429
    • /
    • 2018
  • In this study, various electrochemical experiments were carried out to compare the corrosion characteristics of AA5052-O, AA5083-H321 and AA6061-T6 in seawater. The electrochemical impedance and potentiostatic polarization measurements showed that the corrosion resistance is decreased in the order of AA5052-O, AA5083-H321 and AA6061-T6, with AA5052-O being the highest resistant. This is closely associated with the property of passive film formed on three tested Al alloys. Based on the slope of Mott-Schottky plots of an n-type semiconductor, the density of oxygen vacancies in the passive film formed on the alloys was determined. This revealed that the defect density is increased in the order of AA5052-O, AA5083-H321 and AA6061-T6. Considering these facts, it is implied that the addition of Mg, Si, and Cu to the Al alloys can degrade the passivity, which is characterized by a passive film structure containing more defect sites, contributing to the decrease in corrosion resistance in seawater.

Analysis of Hydrophobic Membrane Fouling on the COD Loading Rates at the State of Passive Adsorption in Membrane Bioreactor (생물학적 막분리 공정에서 수동흡착 상태에서의 유기물 유입 부하에 따른 소수성 막의 오염도 분석)

  • Park, Tae-Young;Choi, Changkyoo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.3
    • /
    • pp.152-158
    • /
    • 2015
  • This paper investigated the membrane fouling potential at the state of passive adsorption which is no permeation with the test modules on COD (Chemical oxygen demand) loading rates, examined the recovery rate and resistance on membrane fouling by three cleaning manners of hydrophobic membrane in a bioreactor. The results showed that high COD loading led to the increase of extra-cellular polymeric substances and filtration resistance. The permeability resistance from 1st day to 63rd day was getting increased, however, the value of permeability resistance after 63th day during the operation period was almost same level at three COD loading rates, it was due that the biomass adhesion on membrane surface at the state of passive adsorption reached to the critical state. Also, the final recovery rates after three cleaning manners were 78%, 72% and 69% at the COD loading concentrations of 250 mg/L, 500 mg/L and 750 mg/L respectively, and then recovery rate by physical cleaning at Run 2 and Run 3 was decreased after 40th day, it proved that biomass cake, which is not easily removed, was formed on the membrane surface because of high COD loading rate and EPS concentration.

Numerical Study on the Extrapolation Method for Predicting the Full-scale Resistance of a Ship with an Air Lubrication System

  • Kim, Dong-Young;Ha, Ji-Yeon;Paik, Kwang-Jun
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.387-393
    • /
    • 2020
  • Frictional resistance comprises more than 60% of the total resistance for most merchant ships. Active and passive devices have been used to reduce frictional resistance, but the most effective and practical device is an air lubrication system. Such systems have been applied in several ships, and their effects have been verified in sea trials. On the other hand, there are some differences between the results predicted in model tests and those measured in sea trials. In this study, numerical analyses were carried out for a model and a full-scale ship. A new extrapolation method was proposed to improve the estimation of the full-scale resistance of a ship with an air lubrication system. The volume of fluid (VOF) method was considered for the numerical models of the air layer. The numerical method was validated by comparing the experimental data on the air layer pattern and the total resistance.

A Study on Power Stability Improvement in the Inductive Coupled RFID Transponder System

  • Kim, Gi-Rae;Choi, Young-Kyu
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.2
    • /
    • pp.150-154
    • /
    • 2007
  • Transponders of RFID system are classified as active or passive depending on the type of power supply they use. In passive transponders the data carrier has to obtain its power from the induced voltage. The induced voltage is converted into direct current using a low loss bridge rectifier and then smoothed. In practice, the induced voltage in the transponder coil is variable according to the coupling coefficient k and the load resistance ($R_L$). Therefore, the rectified voltage is unstable and the transponder of RFID is unstable sometimes. In this paper, a voltage-dependent shunt resistor ($R_s$) circuits are designed and inserted in parallel with the load resistance of RFID transponder in order to improve the stability of power.

A study on Stress Corrosion Cracking of Sensor Wire in Thermally Insulated Underground Pipeline (이중보온관 부식감지선의 응력부식파괴에 관한 연구)

  • Choe, Yun-Je;Kim, Jeong-Gu
    • Korean Journal of Materials Research
    • /
    • v.12 no.2
    • /
    • pp.103-111
    • /
    • 2002
  • The thermally insulated underground pipelines have been used for district heating system. The sensor wire embedded in the insulation was used for monitoring the insulating resistance between the sensor wire and the pipe. The resistance measurement system detects corrosion of steel pipe under insulation. The corrosion and stress corrosion cracking(SCC) characteristics of sensor wire in synthetic ground water were investigated using the electrochemical methods and constant load SCC tests. The polarization tests were used to study the electrochemical behavior of sensor wire. The sensor wire was passivated at temperatures ranging from 25 to $95^{\circ}C$. However, the applied sensing current larger than passive current resulted in breakdown of passive film. The constant load SCC tests were performed to investigate the effects of applied current and load on the fracture behavior. Stress-corrosion cracks initiated at pits that were produced by sensing current. The growth of the pit involves a tunnelling mechanism, which leads to ductile fracture.

Evaluation of Weathered Granite Soil l Geogrid Friction Properties and Pull out Test (화강 풍화토/지오그리드 인발시험 및 마찰특성 평가)

  • 조삼덕;김진만
    • Geotechnical Engineering
    • /
    • v.12 no.4
    • /
    • pp.87-100
    • /
    • 1996
  • The pull -out test has been used to investigate the friction properties between soil and grid type geosynthetics which is useful to measure the passive bearing resistance as well as the skin friction. In this paper, the friction properties between geogrid and a weathered granite soil are investigated by performing various pull-out tests. From the test results, a rational pull out test equipment and test method is suggested by evaluating the effects of major factors (such as geogrid width, location of soil box facing, vertical loads and pulll -out displacement rate, etc.) on pull -out test results.

  • PDF

Analysis of Negative Resistance Maximum Oscillating Frequeney (부저항발진기의 최대주파수 해석(I보))

  • 김영권;서정홍
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.6 no.2
    • /
    • pp.6-20
    • /
    • 1969
  • Tunnel diode oscillator consisting of a tunnel diode(negative-resistance element) and a passive linear load. In this paper maximizing the frequeney of a negative reistance oscillator with varying a passive linear load is investigated. The method of theoretical analysis, utiliying impedance loei in the complex plane and experimental data shows that the maximum frequencies of quasi-harmonic oscillation is higher in the parrallal-RL load than in the resistive load.

  • PDF

Effects of Alloyed Carbon on the General Corrosion and the Pitting Corrosion Behavior of FeCrMnN Stainless Steels (FeCrMnN 계 스테인리스강의 일반부식 및 공식부식 거동에 미치는 고용 탄소의 영향)

  • Ha, Heon-Young;Lee, Tae-Ho;Kim, Sung-Joon
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.10
    • /
    • pp.780-789
    • /
    • 2011
  • The effects of alloyed carbon on the pitting corrosion, the general corrosion, and the passivity behavior of Fe18Cr10Mn0.4NxC (x=0~0.38 wt%) alloys were investigated by various electrochemical methods and XPS analysis. The alloyed carbon increased the general corrosion resistance of the FeCrMnN matrix. Carbon enhanced the corrosion potential, reduced the metal dissolution rate, and accelerated the hydrogen evolution reaction rate in various acidic solutions. In addition, carbon promoted the pitting corrosion resistance of the matrix in a chloride solution. The alloyed carbon in the matrix increased the chromium content in the passive film, and thus the passive film became more protective.

A Study on Passive Microvalve for Glaucoma (녹내장 치료용 수동형 밸브의 제작)

  • Sim, Tae-Seok;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.64-66
    • /
    • 2002
  • This paper reports the design, modeling, fabrication and measurement of passive microvalves applicable to glaucoma implants. The proposed microvalves consisted of microchannels and chambers. The microchannels had a fixed fluidic resistance and generated a pressure difference. The chamber was located in the middle of the microchannels and acted as a buffer preventing an abrupt pressure change from an external variation of the fluid flow. To find optimum design parameters, six kinds of the microvalves were fabricated and experimented.

  • PDF