• Title/Summary/Keyword: Partition wall

Search Result 84, Processing Time 0.022 seconds

Seismic Performance Evaluation of School Building Short Column Effect (끼움벽과 단주효과를 고려한 학교건축물의 내진성능평가)

  • Ju, Chang-Gil;Han, Ju-Yeon;Park, Tae-Won
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.2
    • /
    • pp.33-39
    • /
    • 2014
  • In the case of low-rise buildings in seismic performance evaluation, lateral force resistance of the pillars affects the seismic performance of the building. Evaluation of the seismic performance of the column is determined by the holding performance is evaluated by comparing the shear strength and bending strength it was destroyed bylow intensity. In case of the school building, in order to install the large windows for ventilation and lighting of the partition walls are located between the pillars. The case of the pillars of these, shear failure occurs in the event of an earthquake is often, in the seismic performance evaluation, partition wall and the wall of the shim is evaluated ignoring, pillar of the general pillars If you have to calculate the results of the seismic performance distorted that are destroyed by bending behavior can be evaluated as often. Results of the study, when assessed by distinguishing the effective length of the column, it was found that when a seismic load is applied, it is possible to accurately predict the failure mode, reliable results of seismic performance evaluation of the school building.

A Study on Fire Hazards in Multiple Compartments with Lightweight Partition Walls (경량칸막이 벽체를 통한 다중구획공간에서의 화재위험성에 관한 연구)

  • Park, Sang-Min;Choi, Su-Gil;Jin, Se-Young;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.14-21
    • /
    • 2020
  • This paper presents the study of a fire risk to the backside of two miniatures of ISO 9705 2/5 using a lightweight partition for indoor space division and reproduction of the ISO 9705 test. An SGP partition, stud partition, glass wool panel, urethane foam panel, sandwich panel, and glass partition were selected as the test specimens, which are frequently used in construction. According to the ISO 9705 test standard, stabilization was achieved using a measuring device that recorded data before the ignition of a burner and continued recording for 120 s thereafter. After ignition was achieved, the power was increased to 300 kW for 600 s and then reduced to 100 kW for 600 s. The specimens were subsequently observed for 180 s, and the fire risk to the backside and the fire pattern of the wall unit were analyzed. Owing to the amount of heat generated by the ignition source, the maximum temperature of the backside was observed to be 67.7 ℃ for the SGP partition, 55.1 ℃ for the stud partition, 52.4 ℃ for the glass wool panel, 727.4 ℃ for the sandwich panel, 561 ℃ for the urethane foam panel, and 630.5 ℃ for the glass partition. In the cases of the sandwich and urethane foam panels, the explosion of flammable gas occurred by virtue of fusion of the interior materials. The reinforced glass was fractured owing to the temperature difference between the heat- and nonheat-responsive parts. Ultimately, the fire risk to the nearby section room was deemed to be high.

Nonlinear Dynamic Response Characteristics with Variations in the Lower Stories of Mixed Building Structures (복합구조물의 하부층수 변화에 따른 비선형 동적응답특성)

  • 강병두;전대한;김재웅
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.443-450
    • /
    • 2001
  • The Mixed building structures can be divided into three partition, namely, upper wall, lower frame, and transfer system which link two partitions. The purpose of this study is to investigate the nonlinear response characteristics of structures, as the stories of lower frame of mixed building structures changes. The recorded earthquake ground motions of EI Centro 1940 NS is adopted, and the maximum ground accelerations are adjusted to 55ga1, 110ga1, 220ga1, 330ga1. The conclusions of this study are the following. 1) The responses of model that the story of lower frame is one were different from those of other models. 2) The process of ductility hinge occurrence of member was ends of coupling beam of upper wall and ends of beam of lower frame in 55ga1, bases of shear wall on pit floor in 110ga1, and bases of column of 1F in 220ga1.

  • PDF

Two-Dimensional Laminar Natural Convection Heat Transfer with Surface Radiation in a Cavity (캐비티내에서 표면복사를 고려한 2차원 층류 자연대류 열전달)

  • Park, H.Y.;Park, K.W.;Han, C.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.217-232
    • /
    • 1992
  • A Numerical study on two-dimensional laminar natural convection with and without surface radiation in fully or partially open square cavity was performed. The cavity has one vertical heated wall facing a vertical opening and two horizontal insulated walls. The pressure boundary condition was applied to the opening instead of the velocity boundary condition. The results of this study showed that the increase of partition length decreased the convective and the radiative Nusselt numbers. It was also found that the increase of wall emissivity decreased the convective Nusselt numbers but increased the radiative Nusselt numbers.

  • PDF

Analysis of airborne sound insulation performance by the experiment using small size specimen (축소시편 실험을 통한 공기전달음 차단성능 분석)

  • Kim, Hang;Park, Hyeon Ku;Goo, Hee Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • The residents' demand for the comfortable life is promoting development of wall and window which has high sound insulation performance. To develop wall system, various aspects should be considered on the environment, material, construction and structure. Especially focusing on the acoustical view, the economical solution is one of the most critical point. Recently the interest on the partition wall is being increased, because it is useful for the Rahmen type apartment which is considered as an alternative to reduce floor impact sound. This study examines simplified measurement method of airborne sound insulation applied small size specimen, in order to save money to be used for the standard specimen then to promote the development process. The results showed that the simplified method could be effective for the wall system the sound insulation performance upto Rw 50 dB, and for the judgement of rank order of sound insulation performance of the similar wall type while developing.

Cause Analysis and Countermeasure of Tracking in Mobile Phone Charger (휴대폰 충전기 내 트래킹 발생 원인 분석 및 대책)

  • Park, Jin-Young;Kim, Jae-Hyun;Park, Kwang-Muk;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.71-77
    • /
    • 2016
  • The electrolyte of the capacitor in mobile phone chargers leaks to the power input terminal resulting in tracking on the PCB board to form a carbonized conductive path. As a result of structural analysis of the cause of the tracking, It occurred when the power input terminal and the PCB board were connected directly using the connector. The larger the amount of electrolyte leaked from the capacitor into the power input terminal, or the lower the height of the partition provided between the plug pins of the power input terminal, the higher the tracking occurrence rate. Accordingly, to lower the occurrence rate of tracking in the charger, it is necessary to provide a partition on the capacitor or increase the height of the partition provided on the power input terminal so that the leaked electrolyte does not flow to the power input terminal. In addition, the tracking occurrence rate will be reduced further if the shape of the PCB board touching ther power connection terminal is changed to ${\Pi}$.

A Study on The Compensation Method of Vertical Members of Tall Building (초고층 벽식 건축물의 수직부재 축소량 계측 및 보정)

  • Kim, Woo-Jae;Song, Hwa-Cheol;Park, Hyo-Seon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.404-407
    • /
    • 2004
  • The construction of high-rise buildings is increased. The Vertical Member of tall buildings is inherently shortened and it causes several seriously problems such as tilting of slab, crack within partition wall, deformation of curtain wall. This also affects structural stability by inducing unexpected stress to the structural members such as outrigger. In this study, the column shortening according to revised field information and to compare the analysis results the actual field measurement. Pusan The $\#$, a 51-story apartment building which is currently under construction was chosen for the case study.

  • PDF

The Korean Traditional Color as Emotional Design Approach in Dental Clinic Interior Design (전통 색상을 적용한 치과 실내디자인의 감성적 접근)

  • Kim, Sun-Young;Lee, Kyung-Jae
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.63-64
    • /
    • 2006
  • The design concept of this dental clinic Interior design is emotional color expression for the medical facility. This dental clinic is showing off the new adoption of the Korean primary traditional color pallette for the medical interior design. The graphic wall of the corridor is strongly attracting the eyes of customers while wrapping the corridor wall and partition with rather unconventional primary colored graphic shaping a tooth. Also the vivid and the dynamic atmosphere are emphasized by using the red color in the treatment area and the powder room. For the space programing, I focused on the functionality of each space and the efficiency of the traffic line. Centering around the information desk, the principal traffic line Is divided Into the staffs' private movement and the public movement.

  • PDF

Analysis for computing heat conduction and fluid problems using cubic B-spline function (3차 B-spline 함수를 이용한 열전도 및 유체문제의 해석)

  • Kim, Eun-Pil
    • Journal of computational fluids engineering
    • /
    • v.3 no.2
    • /
    • pp.1-8
    • /
    • 1998
  • We make use of cubic B-spline interpolation function in two cases: heat conduction and fluid flow problems. Cubic B-spline test function is employed because it is superior to approximation of linear and non-linear problems. We investigated the accuracy of the numerical formulation and focused on the position of the breakpoints within the computational domain. When the domain is divided by partitions of equal space, the results show poor accuracy. For the case of a heat conduction problem this partition can not reflect the temperature gradient which is rapidly changed near the wall. To correct the problem, we have more grid points near the wall or the region which has a rapid change of variables. When we applied the unequally spaced breakpoints, the results show high accuracy. Based on the comparison of the linear problem, we extended to the highly non-linear fluid flow problems.

  • PDF

A Study on the Attention Concentration Properties in Convergent Exploration Situations in Cafe Space - Focusing on Gaze and Brain wave Data Analysis - (카페공간에 대한 수렴적 탐색상황에서의 주의집중 특성의 분석 방법에 관한 연구 - 선택적 주시데이터에 의한 뇌파 데이터 분석을 중심으로 -)

  • Kim, Jong-Ha;Kim, Ju-Yeon;Kim, Sang-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.2
    • /
    • pp.30-40
    • /
    • 2016
  • This study analyzed the attention concentration tendencies of one(1) subject who showed convergent exploratory acts actively through the gaze-brainwave measurement experiment of cafe space images and our research findings are as follows. First, the areas of interest (AOIs) that the subject gazed visually by paying attention to it and concentrating on it at a cafe space include counter&menu area, sign area, partition area, image wall area, stairs area, and movable furniture area, and built-in furniture area: seven areas in total. Second, conscious gaze frequency appeared the highest in counter&menu area, and conscious gaze appeared more later than in initial times. Third, conscious gaze pattern was divided into the zone that explored various areas dispersely (distributed exploratory zone) and the zone that explored between particular areas concentratedly (intensive exploratory zone). Fourth, as a result of analyzing the brainwave attention concentration, it was found that the attention concentration in prefrontal lobe (Fp1, Fp2) and frontal lobe (F3, F4) rose to a higher level in the zone of 15 to 16 seconds and this time zone was considered to be a zone where gazing at counter&menu area was very active. In addition, the attention concentration appeared higher in the initial zone than in the later zone, among the entire experimental time zones. Finally, as a result of analyzing the changes in activation by brain portion of the SMR wave expressed when maintaining the arousal and attention concentration, it was found that the right prefrontal lobe and the frontal lobe became activated in the time zone when the intensive exploration of "counter&menu area" and "movable furniture${\leftrightarrow}$built-in furniture area" had occurred and the time zone when the intensive exploration of "image wall${\leftrightarrow}$partition area" and "counter&menu${\leftrightarrow}$sign area" had occurred.