Abstract
In the case of low-rise buildings in seismic performance evaluation, lateral force resistance of the pillars affects the seismic performance of the building. Evaluation of the seismic performance of the column is determined by the holding performance is evaluated by comparing the shear strength and bending strength it was destroyed bylow intensity. In case of the school building, in order to install the large windows for ventilation and lighting of the partition walls are located between the pillars. The case of the pillars of these, shear failure occurs in the event of an earthquake is often, in the seismic performance evaluation, partition wall and the wall of the shim is evaluated ignoring, pillar of the general pillars If you have to calculate the results of the seismic performance distorted that are destroyed by bending behavior can be evaluated as often. Results of the study, when assessed by distinguishing the effective length of the column, it was found that when a seismic load is applied, it is possible to accurately predict the failure mode, reliable results of seismic performance evaluation of the school building.
Keywords
School building; Seismic performance evaluation; Short column; Effect length; Shear strength;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Oh, Chang-Hak, "Lesson of Wenchuan Earthquake in China", Jourmal of KSEA, Serial No.87, pp.32-35, 2008
2 Kim, Hye-Jin, Park, Tae-Won, Cho, Seung-Ho, Lee, Kyung-Koo, Roh, Young-Sook and Lan Chung, "Experimental study on Seismic Retrofitting Methods for school building using aramid strip" Journal of the KOSOS, Vol. 25, No. 3, pp.100-107, 2010   과학기술학회마을
3 Applied Technology Council (ATC-33 Project), "Nehrp Guidelines for the Seismic Rehabilitation of Buildings, FEMA 273", Buildings Seismic Safety Council
4 Applied Technology Council (ATC-43 Project), "Eval u -ation of Earthquake Damaged Concrete and Masonry Wall buildings, FEMA 306", The Partnership for Response and Recovery
5 Yoo, Han-Kook, Park, Tae-Won, Lee, Sang-Hyun , Lan, Chung, and Cho, Seong-Ho, "Seismic Performance Evaluation of School Buildings in Gyunggi Region Considering Seismic Hazard Map", Journal of the KOSOS, Vol. 24, No. 4, pp.66-73, 2009   과학기술학회마을
6 Korea Concrete Institute, "Concrete Design Code", 2012
7 Ministry of Land, Infrastructure and Transport, "Korea Building Code", 2009
8 Sinan Altin, Ozgur Anil, M. Emin Kara, Mustafa Kaya, "An experimental study on strengthening of masonry infilled RC frames using diagonal CFRP strips", Composites Part B: engineering, Vol. 39, No.4, pp. 680-693, 2008   DOI   ScienceOn
9 Sheilh, S.A. and Khoury, S.S. "A Performance -Based Approach for the Design of Confining in Tie Columns", ACI Structural Journal, pp.421-431, 1997