• Title/Summary/Keyword: Paralleled operation

Search Result 32, Processing Time 0.027 seconds

Cell-balancing Algorithm for Paralleled Battery Cells using State-of-Charge Comparison Rule

  • La, Phuong-Ha;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.156-158
    • /
    • 2018
  • The inconsistencies between paralleled battery cells are becoming more considerable issue in high capacity battery applications like electric vehicles. Due to differences in state-of-charge (SOC) and internal resistance within individual cells in parallel, charging or discharging current is not appropriately balanced to each cell in terms of SOC, which may shorten the lifetime or sometimes cause safety issues. In this paper, an intelligent cell-balancing algorithm is proposed to overcome the inconsistency issue especially for paralleled battery cells. In this scheme, SOC information collected in the sub-BMS module is sent to the main-BMS module, where the number of parallel cells to be connected to DC bus is continuously updated based on the suggested SOC comparison rule. To verify the method, operation of the algorithm on 4 paralleled battery cells are simulated on Matlab/Simulink. The simulation result shows that the SOCs of paralleled cells are evenly redistributed. It is expected that the proposed algorithm provides high reliable and prolong the life cycle and working capacity of the battery pack.

  • PDF

A Novel Paralleling Method of Converters for Reduction of Hippie in Output Voltage (컨버터의 출력전압 리플 저감을 위한 새로운 병렬운전 방법에 대한 연구)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Beak;Jang, Sung-Soo;Kim, Jong-Duck
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.237-240
    • /
    • 2004
  • For the paralleled operation of DC/DC converters, the current sharing between each modules is the most important for the reliability of the power system. Interleaving method is commonly used with many paralleling schemes for the reduction of the ripple in the output voltage of paralleled converters and there are many commercial IC for interleaving application appliable. But for all of them, it is impossible to detect the number of module in operating and then change the phase of them automatically. In this paper, a novel paralleling method is proposed for the converter parallel operation, which detects the number of modules in active and sets the phases of PWM signals applied to each modules autonomously. This can greatly improve the output voltage ripple and reliability of the system. The expandibility of modular number can be done very easily by just adding several parts.

  • PDF

Analysis on Surge generated in N Module Paralleled Capacitor Bank and Countermeasure for Suppression (N개 모듈로 구성된 커패시터 뱅크의 써지전압 발생 원인 분석 및 억제 대책)

  • Kim, Jin-Sung;Choi, Young-Ho;Jung, Jae-Won;Chu, Jeung-Ho;Sung, Gi-Yeul;Jin, Yun-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1597-1599
    • /
    • 2001
  • In this paper, two types of surge voltage generated in the only operation of capacitor bank composed of paralleled multi-modules are analyzed and also studied to suppress those. The surge voltage can give malfuction to the operation of capacitor bank and destroy the expensive components at the worst. The conditions and causes of surge voltage generation and the countermeasure for suppression are presented.

  • PDF

A Study for Small Cogeneration System Intertie (소형열병합 발전설비 계통연계 상용운전에 관한 연구)

  • Park, K.W.;Kim, W.T.;Yoon, K.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.166-168
    • /
    • 2001
  • Generation by the privately owned generators, which are normally operated has occupied about 10% of total generation. Recently the small co-generation employed gas engine has been introduced and attracted public interest. For privately owned generator to be paralleled Utilities, a customer complies with Generator Parallel Operation Guideline set by Utilities and installs related protective relays. But the guideline is not specified to small co-generation, only provides parallel operation of privately owned generator. So applying this guideline, initial investment can be too high comparing to total co-generation cost. Besides there is no specified guide about ALTS, which arises asynchronous problem. In this paper we analyzed guideline and technical problem when small co-generation is paralleled. And additionally needed researching area to improve distribution of small co-generation is discussed.

  • PDF

Dynamic Paralleling Behaviors of High Power Trench and Fieldstop IGBTs

  • Wu, Yu;Sun, Yaojie;Lin, Yandan
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.788-795
    • /
    • 2014
  • This paper demonstrates the dynamic behaviors of paralleled high power IGBTs using trench and fieldstop technologies. Four IGBTs are paralleled and standard deviation is adopted to represent the imbalance. Experiments are conducted under three different operation conditions and at different temperatures ranging from $-25^{\circ}C$ to $125^{\circ}C$. The experimental results show that operation at very low and very high temperatures usually aggravates the switching behaviors. There is a trade-off between the balance and the losses at low temperatures. These results can help in the design of heat sinks in paralleling applications confronting very low temperatures.

A Study on Parallel Operation of PWM Converter for Auxiliary bloc High Speed Train (고속전철 보조전원장치용 PWM 컨버터의 병렬운전에 관한 연구)

  • 송상훈;성재원;김연충;원충연;최종묵;기상우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.358-361
    • /
    • 1999
  • In auxiliary block of high speed train power factor correction and harmonics reduction is very important issue for efficient energy transport. The GTO-equipped PWM converter is used for traction untill resently. But the rising power capability of IGBTs resently allows to build IGBT-equipped PWM converter with a considerably increased switching frequency. This paper presents switching pattern, control method, operation mode and tuned filter to reduce dc link voltage ripple for paralleled converter.

  • PDF

Elimination of the State-of-Charge Errors for Distributed Battery Energy Storage Devices in Islanded Droop-controlled Microgrids

  • Wang, Weixin;Wu, Fengjiang;Zhao, Ke;Sun, Li;Duan, Jiandong;Sun, Dongyang
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1105-1118
    • /
    • 2015
  • Battery energy storage devices (ESDs) have become more and more commonplace to maintain the stability of islanded power systems. Considering the limitation in inverter capacity and the requirement of flexibility in the ESD, the droop control was implemented in paralleled ESDs for higher capacity and autonomous operation. Under the conventional droop control, state-of-charge (SoC) errors between paralleled ESDs is inevitable in the discharging operation. Thus, some ESDs cease operation earlier than expected. This paper proposes an adaptive accelerating parameter to improve the performance of the SoC error eliminating droop controller under the constraints of a microgrid. The SoC of a battery ESD is employed in the active power droop coefficient, which could eliminate the SoC error during the discharging process. In addition, to expedite the process of SoC error elimination, an adaptive accelerating parameter is dedicated to weaken the adverse effect of the constraints due to the requirement of the system running. Moreover, the stability and feasibility of the proposed control strategy are confirmed by small-signal analysis. The effectiveness of the control scheme is validated by simulation and experiment results.

Fault-tree based reliability analysis for paralleled half-bridge sub-module of HVDC (HVDC 병렬 하프브리지 서브모듈에 대한 고장나무기반의 신뢰성 분석)

  • Kang, Feel-soon;Song, Sung-Geun
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1218-1223
    • /
    • 2019
  • In HVDC systems, the full-bridge submodule increases the number of components compared to the half-bridge submodule, but the failure-rate can be reduced by securing 100 % redundancy. However, full-bridge submodules require more complex control algorithms to ensure the redundancy and to prevent arm-short with sufficient dead-time. To solve this problem, we analyse the failure-rate of the paralleled half-bridge configuration with the same number of components and 100 % redundancy as the full-bridge submodule. The fault tree analysis (FTA) method is applied to the conventional part failure analysis to reflect the operation risk of the submodule, thereby predicting the life-cycle of the submodule more accurately. To verify the validity, the failure-rate results of the proposed FTA based analysis method are compared with the failure rate obtained by the part failure method.

A Study about Output Filter of Paralleled Three-Phase Grid-Connected PV Inverters

  • Vu, Trung-Kien
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.271-272
    • /
    • 2011
  • The rising popularity of renewable energy sources resulted in development of the units of higher rated powers. As a result of the limited power handling capacity of individual devices, paralleling is the choice to increase the equipment rating, while keeping the THD of the current at the PCC within the agency specified standards. And their typical power circuit configuration limits the stress on individual devices to an appreciable extent. The main scope of this paper is the analysis of filter structure in paralleling inverter system's operation. Simulation results are shown to verify the theoretical analysis.

  • PDF

Reduction Harmonic of Auxiliary Block for High Speed Train (고속전철용 보조전원장치의 고조파저감)

  • 송상훈;김연충;원충연;최종목;기상우;배기훈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.162-167
    • /
    • 1999
  • In Auxiliary block of High speed train Power factor correction and Harmonics reduction is very important issue for efficient energy transport. The GTO-equipped PWM converter is used for traction untill resently. but the rising power capability of IGBTs resently allows to build IGBT-equipped PWM converter with a considerably increases switching frequency. In this paper presents switching pattern, control method, operation mode and tuned filter to reduce dc link voltage ripple for paralleled converter.

  • PDF