• Title/Summary/Keyword: Parallel connection

Search Result 358, Processing Time 0.025 seconds

병렬연결법에 의한 1.8V CMOS Self-bias 고속 차동증폭기의 이득 개선 (The Gain Enhancement of 1.8V CMOS Self-bias High-speed Differential Amplifier by the Parallel Connection Method)

  • 방준호
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1888-1892
    • /
    • 2008
  • In this paper, a new parallel CMOS self-bias differential amplifier is designed to use in high-speed analog signal processing circuits. The designed parallel CMOS self-bias differential amplifier is developed by using internal biasing circuits and the complement gain stages which are parallel connected. And also, the parallel architecture of the designed parallel CMOS self-bias differential amplifier can improve the gain and gain-bandwidth product of the typical CMOS self-bias differential amplifier. With 1.8V $0.8{\mu}m$ CMOS process parameter, the results of HSPICE show that the designed parallel CMOS self-bias differential amplifier has a dc gain and a gain-bandwidth product of 64 dB and 49 MHz respectively.

VB5.2 인터페이스를 위한 연결 제어 프로토콜과 병렬형 연동 모델 (Connection Control Protocol and Parallel Interworking Model for the VB5.2 Interface)

  • 차영욱;김춘희;한기준
    • 한국산업정보학회논문지
    • /
    • 제5권2호
    • /
    • pp.22-31
    • /
    • 2000
  • B-ISDN 환경의 VB5.2 인터페이스는 B-BCC 프로토콜을 이용하여 액세스 망과 서비스 노드 사이에서 ATM 자원의 동적인 할당 및 해제 기능을 제공한다. 본 논문에서는 액세스 망의 도입으로 인한 연결 선정 지연을 향상시키기 위하여 VB5.2 인터페이스의 B-BCC 프로토콜을 개선시킨 B-ANCC 프로토콜과 서비스 노드에서 VS5.2 인터페이스의 연결 제어 프로토콜이 신호 프로토콜과 병렬형으로 연동하는 모델을 제안하였다. 본 논문에서 제안한 B-ANCC 프로토콜의 정확성을 확인하기 위하여 자동 도구인 SPIN을 이용하여 검증하였으며, 큐잉 모델 분석과 시뮬레이션을 통하여 B-BCC 프로토콜 기반의 순차형 연동 모델과 B-ANCC 프로토콜 기반 병렬형 연동 모델의 연결 설정 지연 및 완료비에 대한 비교, 분석을 수행하였다. 분석 결과 VB5.2 인터페이스의 연결 제어 프로토콜로 B-BCC 대신 B-ANCC를 사용하고 병렬형 연동 방식을 사용함으로써, 연결 설정 지연과 완료비 모두를 향상시킬 수 있음을 알 수 있었다.

  • PDF

임플랜트 지대주에 따른 나사 풀림의 연구 (THE INFLUENCE OF IMPLANT FIXTURE-ABUTMENT CONNECTION DESIGN ON SCREW LOOSENING)

  • 문양숙;박상원;방몽숙;양홍서;박하옥
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.174-184
    • /
    • 2006
  • Purpose: Current trend in implant dentistry is changing from external connection to internal connection. To evaluate the splinting of external and internal connection implant on screw loosening, 2-units prosthesis was fabricated with BioPlant $System^(R)$ of external connection type and Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. Material and Method: Experimental group is classified into three groups. 1) $G_1-EE$: 2-units prosthesis was fabricated with two Bioplant $System^(R)$ of external connection type. 2) $G_1-EI$: 2-units prosthesis was fabricated with one BioPlant $System^(R)$ of external connection type and one Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. 3) $G_1-II$: 2-units prosthesis was fabricated with two Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. In fabricating 2-units prosthesis, two hexed abutments are recommended when two implants are installed parallel, otherwise one hexed abutment is used on major occlusal force area and one nonhexed abutment is used on the other area. Since it is rare to find two implants being parallel, it is hard to fabricate prosthesis with passive adaptation using two hexed abutments. It is much more difficult to acquire passive adaptation when using hex abutment compared to nonhex abutment. To evaluate the influence of hexed and nonhexed abutment on screw loosening, 2-units prosthesis was fabricated with hexed and nonhexed abutment. Experimental group is classified into three groups. 1) $G_2-HH$: 2-units prosthesis was fabricated with two hexed abutments. 2) $G_2-HN$: 2-units prosthesis was fabricated with one hexed abutment and one nonhexed abutment. 3) $G_2-NN$: 2-units prosthesis was fabricated with two nonhexed abutments. Result: The results of comparing the detorque value after loading on a each prosthesis periodically are as follows. 1. In splinting group of external and internal connection implant, $G_1-II$ group demonstrated the biggest detorque value, followed by $G_1-EI$ group and $G_1-EE$ group. 2. There is no notable significance between external connection implant of $G_1-EI$ group and $G_1-EE$ group and also no significance between internal connection implant of $G_1-EI$ group and $G_1-II$ group. 3. $G_2-HH$ group showed higher detorque value than $G_2-HN\;and\;G_2-NN$ group. From the results, we can concluded that using both external connection and internal connection implant together is clinically acceptable and in order to acquire a good passive adaptation in fabricating 2-units implant prosthesis we can use two nonhexed abutments.

이동 컴퓨팅 서비스를 위한 부분 연결 관리자의 설계 및 프로토타입핑 (Design and Prototyping of Partial Connection Manager for Mobile Computing Service)

  • 김평중;윤석환;진성일
    • 한국정보처리학회논문지
    • /
    • 제7권6호
    • /
    • pp.1932-1940
    • /
    • 2000
  • We must solve problems caused by mobile computing environments for supporting efficient mobile computing services. The problem is the use of wireless medium having high error rates and low bandwidth, and the sudden network disconnection to reduce the power consumption of a mobile host and the cost of the network connection. For these problems, we proposed the architecture of the partial connection manager and designed and implemented that in this paper. In particular, The partial connection manager creates the limited number of mobile agents according to priority and sends them in parallel to server systems and combines results of them process rapidly the user request. By applying the proposed partial connection manager to the mobile computing services called cybermarket, we knew that the mobile agent technique could be suited to the mobile computing environment and overcome the partial connection problem caused by eh mobile computing environment.

  • PDF

LIGHTLIKE SUBMANIFOLDS OF A SEMI-RIEMANNIAN MANIFOLD WITH A SEMI-SYMMETRIC NON-METRIC CONNECTION

  • Yucesan, Ahmet;Yasar, Erol
    • 대한수학회보
    • /
    • 제47권5호
    • /
    • pp.1089-1103
    • /
    • 2010
  • In this paper, we study lightlike submanifolds of a semi-Riemannian manifold admitting a semi-symmetric non-metric connection. We obtain a necessary and a sufficient condition for integrability of the screen distribution. Then we give the conditions under which the Ricci tensor of a lightlike submanifold with a semi-symmetric non-metric connection is symmetric. Finally, we show that the Ricci tensor of a lightlike submanifold of semi-Riemannian space form is not parallel with respect to the semi-symmetric non-metric connection.

병렬 운전되는 선형 유도전동기의 추력 계측 (Thrust Measurement of Parallel-operated Linear Induction Motors)

  • 김경민;이원민;박승찬;김정철;박영호;김국진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1599-1604
    • /
    • 2007
  • LIMs propelling the MAGLEV which has been developed in Korea have 3-series and 2-parallel connection, so that 6 LIMs per one vehicle are fed by one inverter. Thrust performance of the parallel-operated LIMs can be different from each other because of variant magnetic air gaps and electrical impedance. The thrust difference between the parallel LIMs cause a twist force on the vehicle. This paper proposes an algorithm to measure thrust of the parallel-operated LIMs. The method uses a digital signal processor(TMS320F2812), voltage and current sensors. As a result, thrust, flux and currents of the parallel-operated small LIMs which are manufactured in our laboratory are monitored by the developed measurement system.

  • PDF

A NEW CLASSIFICATION OF REAL HYPERSURFACES WITH REEB PARALLEL STRUCTURE JACOBI OPERATOR IN THE COMPLEX QUADRIC

  • Lee, Hyunjin;Suh, Young Jin
    • 대한수학회지
    • /
    • 제58권4호
    • /
    • pp.895-920
    • /
    • 2021
  • In this paper, first we introduce the full expression of the Riemannian curvature tensor of a real hypersurface M in the complex quadric Qm from the equation of Gauss and some important formulas for the structure Jacobi operator Rξ and its derivatives ∇Rξ under the Levi-Civita connection ∇ of M. Next we give a complete classification of Hopf real hypersurfaces with Reeb parallel structure Jacobi operator, ∇ξRξ = 0, in the complex quadric Qm for m ≥ 3. In addition, we also consider a new notion of 𝒞-parallel structure Jacobi operator of M and give a nonexistence theorem for Hopf real hypersurfaces with 𝒞-parallel structure Jacobi operator in Qm, for m ≥ 3.

부하를 분담하고 있는 디젤발전기의 무한대 모선과의 병렬운전 시스템 (Parallel Running System of the Loaded Diesel Generator to Infinite Bus)

  • 천행춘
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.1017-1025
    • /
    • 2004
  • Generally generator is connected to the bus with no load. After the connection to the bus. the frequency of generator system with no load has to be increased for preventing the reverse power. But in a few case of parallel running with infinite bus system, we have to synchronize the loaded generator to the infinite bus. The frequency of generator system with load has to be lowered for prevention of load shift to the bus system. The blackout of infinite bus decreases the parallel running generator's frequency because of load increasing. In this paper we propose a method that the generator with load maintains the frequency constantly after the blackout of infinite bus. With the constant speed control and load control method of parallel running system to the infinite bus we apply the method to the industrial generating system.

직렬 및 병렬 Sin+Cos 전력계통안정화장치 (Series and Parallel Sin+Cos PSS)

  • 이상성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.87-89
    • /
    • 2005
  • This paper proposes new series and parallel Sin+Cos PSS(power system stabilizer) for the purpose to improve the existing PSS1A's performance. The purpose of PSS is used to enhance damping of power system oscillations through injection of auxiliary signal for an excitation control terminal. The Proposed series and Parallel Sin+Cos PSS is connected adding the Sin+Cos terms additionally with serial and with parallel connection in a conventional PSS1A. The proposed controller is aim to considering of a damping of oscillation when it changes parameter fluctuations or operational load variations in a power system. The object of electric power system is KEPCO system and the voltage of power transmission line is a 154kV and a 345kV. The PSCAD/EMTDC package is used to authorize the effect of the proposed controller. Simulations were shown by and compared with the waveforms for frequency, voltage and electric power.

  • PDF